  1. Replies
    56
    Views
    4,677

    I appreciate it I was just talking about my...

    I appreciate it I was just talking about my experiences that's all :)
  2. Replies
    56
    Views
    4,677

    I have never had hoses leak unless the gasket was...

    I have never had hoses leak unless the gasket was bad which I change regularly, or I didnt tighten the connection.
  3. Replies
    15
    Views
    1,083

    Sorry didnt mean to double post

    Sorry didnt mean to double post
  4. Replies
    15
    Views
    1,083

    Is the motor sealed or vented? What was the amp...

    Is the motor sealed or vented? What was the amp draw while running? Is it 3 wire or 5 wire fan motor? Can we get the motor info original preferrably. Has the contactor or relay line voltage to load...
  5. Replies
    15
    Views
    1,083

    Is the motor sealed or vented? What was the amp...

    Is the motor sealed or vented? What was the amp draw while running? Is it 3 wire or 5 wire fan motor? Can we get the motor info original preferrably. Has the contactor or relay line voltage to load...
  6. Replies
    9
    Views
    878

    however shophound could be right that it could be...

    however shophound could be right that it could be the compressor.
  7. Replies
    9
    Views
    878

    not sure if that unit would have it or not but i...

    not sure if that unit would have it or not but i know some york 10 ton units R 410a have an ambient air head pressure control which takes single speed motors and pulses them giving the illusion they...
  8. Replies
    56
    Views
    3,647

    I agree with 2sac, i had a similar problem on a...

    I agree with 2sac, i had a similar problem on a walk in. i suggest clipping the pigtail on the power head, its a small nitrogen charge that will bleed off unless the diaphragm is punctured then it...
  9. Replies
    15
    Views
    1,083

    is the incoming voltage correct? what is the amp...

    is the incoming voltage correct? what is the amp draw. does the new motor match the old motor specs? was the direction correct? was the cap the right size and voltage rating? is the coil clean?
  10. Replies
    56
    Views
    4,677

    I have the testo 557 guages also and the micron...

    I have the testo 557 guages also and the micron reading is way off. had a system that pulled down to 500 microns and my guage was reading 17000. tried to zero the guages a couple times. no change. i...
  11. Replies
    47
    Views
    2,806

    Internal Pressure relief. He had said earlier...

    Internal Pressure relief. He had said earlier there was a hissing sound.
  12. Replies
    47
    Views
    2,806

    If at opens at 250- 300psi

    If at opens at 250- 300psi
  13. Replies
    47
    Views
    2,806

    All other info correct? If it is then all I know...

    All other info correct? If it is then all I know is there could be a restriction some where or the compressor has a weak overload
  14. Replies
    47
    Views
    2,806

    Also are the valves on the condensing unit open?

    Also are the valves on the condensing unit open?
  15. Replies
    47
    Views
    2,806

    just to make sure i fully understand what is...

    just to make sure i fully understand what is wrong here, you changed out a condensing unit and txv to one that operates on R22, you tried to add charge and had problems getting proper charge into the...
  16. Replies
    47
    Views
    2,806

    i disagree if the txv is wide open and the...

    i disagree if the txv is wide open and the condenser fan is running then there should not be any flash gas unless its low on charge. a wide open txv will allow frost to come back on the suction line...
  17. Replies
    9
    Views
    429

    I agree with pecmsg, trying to recycle...

    I agree with pecmsg, trying to recycle refrigerant and then reuse it in the same system may save some money now and it could cost a lot more down the road. I would send it out just to be safe. Small...
  18. Replies
    47
    Views
    2,806

    if you replaced the filter drier and passed...

    if you replaced the filter drier and passed nitrogen through the coil while it was open to make sure no oil was blocking it then i would say you have a txv slammed closed.
  19. Replies
    47
    Views
    2,806

    replace the txv

    replace the txv
  20. Replies
    25
    Views
    1,328

    Im surprised no responses to the "theres a sizzle...

    Im surprised no responses to the "theres a sizzle in my barrel" what gives?
  21. Replies
    17
    Views
    1,355

    Phase out

    Phase out
  22. Replies
    30
    Views
    4,672

    Much appreciated. The info I got lacked some...

    Much appreciated. The info I got lacked some theory. What you guys are saying makes sense. At first I was thinking for systems without recievers not sure if my theory would still apply to keep the...
  23. Replies
    6
    Views
    560

    ammoniadog i would assume that your username...

    ammoniadog i would assume that your username implies you specialize in ammonia systems?
  24. Replies
    25
    Views
    1,328

    theres a sizzle in my barrel TURN IT OFF!!...

    theres a sizzle in my barrel TURN IT OFF!!
    theres a sizzle in my barrel TURN IT OFF!!
    oh your screwed and you will know it
    when you reach and try to get it
    theres a sizzle in my barrel TURN IT...
  25. Replies
    17
    Views
    1,355

    also some people replace it with R 414b however...

    also some people replace it with R 414b however it probably wont last long due to the fact it contains R22