  1. Siemens TEC resetting itself every 30-40 seconds

    I have a newly installed Siemens TEC, application 2050 that is resetting itself every 30 to 40 seconds on average.....it loses connection with insight and physically powers itself off and then back...
  2. Replies
    8
    Views
    1,022

    Siemens TEC Application 2050

    I've got a few of these that I suspect are wired on opposite DO's from where they should be and it's causing the control to be reversed. Can anyone email me the guide for 2050 that would tell me...
  3. AB Powerflex VFD comm. to Siemens P1 FLN @ 9600 baud

    I have had hit and miss success hooking up trunks consisiting of one to six Allen-Bradley Powerflex 400 VFD's to FLN trunks in our Siemens control panels. Sometimes I hook them up and configure the...
  4. USB connection to PXC100 modular for config

    I'm trying to perform initial addressing, BLN naming, etc. type tasks on a brand new Siemens PXC100.96a controller for our apogee system. I have one of those printer type USB cables with the type...
  5. Replies
    5
    Views
    1,092

    That some interesting info in regards to the...

    That some interesting info in regards to the "true bacnet" vs. P2 loaded with bacnet drivers. I wonder if there is any visual way to tell by looking? I'm guessing its the latter but it was put in...
  6. Replies
    5
    Views
    1,092

    BACnet Raypack to Siemens PXC modular

    We have a Siemens panel that already has the BACnet drivers in it and is currently talking to 3 BACnet capable York Chillers. I'd like to also add 2 Raypack Hybrid + boiler controllers onto the FLN...
  7. Replies
    0
    Views
    695

    Danfoss Turbocor Remote Monitoring

    I believe the equipment we have is capable of handling remote communications to the two turbocor compressors we have in another building over tcp/ip.

    There is a 4 port serial device server (Moxa...
  8. Replies
    7
    Views
    1,230

    How would one go about checking for "dead JNL"...

    How would one go about checking for "dead JNL" files? Our server based Insight is also slow, not hours slow though.
  9. Replies
    7
    Views
    1,232

    Alright, I got into the SCT using the second...

    Alright, I got into the SCT using the second method, and am currently synchronizing the archive. Hopefully this is the right thing to do.
  10. Replies
    7
    Views
    1,232

    I'm sorry, but what is SCT? This Metasys system...

    I'm sorry, but what is SCT? This Metasys system is all new to me, since we use Insight at our other buildings. The person who normally does this here is out on extended mecical leave so I am trying...
  11. Replies
    7
    Views
    1,232

    Metasys graphics backup

    The techs at one of our sites that I'm not familiar with have reported one of their graphics is missing. It was a summary page with key info from each of the buildings AHU's on it. The system has...
  12. Replies
    3
    Views
    609

    JCI NAE alarm clearing

    Does anyone know how to clear several or all of the alarms on an NAE in one batch? There are tons of them that would take forever to go through and clear one at a time as they "pop up".
  13. Replies
    19
    Views
    4,433

    Thanks for putting this up, I downloaded the file...

    Thanks for putting this up, I downloaded the file and it looks like a pretty slick interface for setting up AEM's. Is there a way to upload the configuration that's already in an existing one to see...
  14. Replies
    19
    Views
    4,433

    Figured this one out by trial and error. I had...

    Figured this one out by trial and error. I had the baud rates set right but the Modem (Enable/Disable) parameter in the field panel needs to be set to "disabled" when connected to an AEM. Seems...
  15. Replies
    19
    Views
    4,433

    I figured out the default password....it is...

    I figured out the default password....it is "system" for future reference.

    Now for the rest of my problem...

    What I've got is a remote BLN that's been functioning okay for at least a few years...
  16. Replies
    19
    Views
    4,433

    Does anyone know the default password for an AEM...

    Does anyone know the default password for an AEM 2100?
  17. Replies
    7
    Views
    1,194

    I didn't have the "original" configuration file...

    I didn't have the "original" configuration file but I was able to upload the configuration from the controller. I then printed out the Q/A section of it and then created a brand new program with the...
  18. Replies
    7
    Views
    1,194

    VAV100-0 trouble

    I've got a JCI VAV controller that is behaving weird by locking almost all of its values at 0. It is tied into a Siemens Apogee Insight workstation and I have attached the screen display. Other...
  19. Report for points currently in OPER priority?

    I'm trying to find a way to see just the points on the system (Siemens Apogee with Insight 3.10) that are currently in the OPER priority level but can't seem to figure out how. Anyone know?
  20. Ah, I get it now. I never knew that virtual...

    Ah, I get it now. I never knew that virtual points could be assigned an address until I clicked on the three periods next to the empty box where a conventional address would go. Then I also created...
  21. I'm not sure that that means exactly. My command...

    I'm not sure that that means exactly. My command point it "AB.CTWR1.SS". Triggering that point on will start my fan.
  22. For example I was trying to set it up like this:...

    For example I was trying to set it up like this:

    01151 C PROOF STATUS FOR FANSÂ
    01152 IF ("AB.FAN1.CURRENT" .GT. 0.00) THEN ON("AB.CTWR1.SS#2")
  23. Siemens - L2SL point set up as virtual proof

    I'm trying to set up an L2SL point to use a virtual proof point instead of a hard wired input from a current sensor. I was then going to set up a logic statement in PPCL to trigger this virtual...
  24. Replies
    4
    Views
    1,105

    I haven't tried running it at 60 Hz in hand as of...

    I haven't tried running it at 60 Hz in hand as of yet. It will run there in auto but only for about 12 minutes or so. Everything looks okay in the settings as far as I can tell. The drive has been...
  25. Replies
    4
    Views
    1,105

    F64 - Drive Overload Fault

    I've got an Allen-Bradley VFD (Powerflex 400) that's been having overload faults for no clear reason. It is driving a single cooling tower fan. I can run it in hand at around 42 Hz and it does...
  26. That's a good idea, I will check into that. I...

    That's a good idea, I will check into that. I know we have tons of points in trend so it will take a while to go through them all.
  27. Siemens Database Transfer - continuous upload!

    We have noticed that our Apogee system is taking a long time to load graphics screens and perform other functions. We are using Insight 3.10. I have noticed that in the database transfer utility...
  28. Replies
    7
    Views
    1,416

    I'm also needing a pdf for application 2050. I...

    I'm also needing a pdf for application 2050. I just need to confirm that my valve should be wired to D01, C, and D02. The terminal marked "C" between each DO is a shared rail to "common" correct?
  29. Replies
    1
    Views
    430

    Siemens inverted point

    I've got a couple of air handlers where the outside air damper is showing up at -0% outdoor air. Then if you go to the commender window, then it shows that the ceiling is 0% and the bottom range is...
  30. Replies
    25
    Views
    5,775

    If anyone has a copy of WCIS that they could send...

    If anyone has a copy of WCIS that they could send my way, I'd really appreciate it.
  31. Replies
    12
    Views
    1,128

    What should I be using as the input and output...

    What should I be using as the input and output tag?
  32. Replies
    12
    Views
    1,128

    Specifically LRS5.

    Specifically LRS5.
  33. Replies
    12
    Views
    1,128

    It looks like XTD07 is activated by a module...

    It looks like XTD07 is activated by a module called LRS1-32. What does LRS1-32 do?
  34. Replies
    12
    Views
    1,128

    It's been many years since I've worked with one...

    It's been many years since I've worked with one of these controllers and wondered if anyone could give me any hints on how to program in maybe a 30 second delay or so before it energizes that DO?
  35. Replies
    12
    Views
    1,128

    I've considered that option and even found an...

    I've considered that option and even found an IDEC timer delay relay, however they would prefer that we exhaust our programming options first.
  36. Replies
    12
    Views
    1,128

    DX-9100 alarm delay

    We are using a DX-9100 in an engine test cell environment and using it to control the ventilation for the room along with the cooling water flow for the engine. There are differential pressure...
  37. Replies
    3
    Views
    893

    Thanks for the heads up; added email to profile.

    Thanks for the heads up; added email to profile.
  38. Replies
    3
    Views
    821

    I meant to type AI-1, sorry about that. So yes...

    I meant to type AI-1, sorry about that. So yes it is in fact landed on an AI and also the jumper is moved to the lowermost position for RTD.
  39. Replies
    3
    Views
    821

    Siemens duct sensor 100k ohm trouble

    I just added a sensor # 535-741-18 to AO1 of a point expansion module on an FLN of an SCU. I used the slope and intercept calculator in point editor and came out with 1 and 0 respectively. Under...
  40. I think I may have figured out the problem. ...

    I think I may have figured out the problem. According to the panel configuration report, the baud speed for FLN 1 is 4800, but FLN2 and FLN3 are 9600. I haven't tried adjusting the baud speed of my...
  41. Adding expansion module to SCU - Siemens

    I'm trying to add a point expansion module with 4 ai's and 4 ao's to an old SCU panel that we have. There are currently 4 PXM's and one TEC on FLN1. I am planning to make this next PXM addressed as...
  42. Replies
    3
    Views
    893

    Siemens application 2267

    Does anyone have a copy of the manual for a TEC application 2267 Dual Duct VAV? I'm trying to understand why point (078) CTL TEMP and point (004) Room temp may be different from each other.
  43. They are regular daisy chained FLN's, not...

    They are regular daisy chained FLN's, not wireless. I've now started to see similar behavior on a couple of other field panels as well.
  44. It's completely random across both FLN's on that...

    It's completely random across both FLN's on that particular panel.
  45. Z8 Return from failure? (Siemens Insight)

    We have a pxc modular panel with two FLN's that is having repeated but short failures being reported on the BLN alarm message screen. We are using version 3.10 btw. It seems to happen on both...
  46. Replies
    3
    Views
    679

    Siemens applic. 2070 "RVAL SWITCH"

    I'm trying to figure out what point (084) does on Siemens application 2070. It is looking for a PCT (%) value.
  47. Thanks everyone, that did the trick! Just to...

    Thanks everyone, that did the trick! Just to confirm if anyone else searches for this, I went in through global commander in insight and changed the value from 0 to 4 on point 59. I didn't end up...
  48. Siemens TEC application 2071 for heat pump

    We recently had to replace a heat pump at one of our buildings with one from a different vendor than the others. What is creating a problem is the reversing valve. On this particular unit, the...
  49. Replies
    4
    Views
    1,002

    For others that might come across this, I am...

    For others that might come across this, I am happy to report that the valve is working correctly. So don't be alarmed if you see that field grayed out and it is firmware 2.85.
  50. Replies
    4
    Views
    1,002

    Thanks, Daramoe. I am using Insight 3.10. And...

    Thanks, Daramoe. I am using Insight 3.10. And yes the valve is a belimo 2-10v model. In system profile, it is listed as panel type: compact, and the firmware is rev. 2.85. I am thinking you are...