  1. Replies
    4
    Views
    318

    The expansion module is discovering (as a device)...

    The expansion module is discovering (as a device) using the Maxline driver, so I'd assume its P1 communication?
  2. Replies
    4
    Views
    318

    OK. Was given WCIS 2.1.1 which doesn't have the...

    OK. Was given WCIS 2.1.1 which doesn't have the terminal emulation. Does anyone have a newer version?
  3. Replies
    4
    Views
    318

    Siemens TEC Expansion Modules

    Pulling in Siemens into Ax

    Have some MAUs that are using app 2497 with expansion module PXM-AI8. I see the points mapping for the 2497 (DOs and DIs), but haven't figured out how to pull sensor...
  4. Replies
    1
    Views
    214

    Nevermind. Finally found owner's manual which...

    Nevermind. Finally found owner's manual which gives me enough info.
  5. Can you upload/download the controller? Also,...

    Can you upload/download the controller? Also, make sure the xml path points to the correct location, (i.e. lonHoneywellAxWizard.lmnl )
  6. Replies
    1
    Views
    214

    Siemens TEC Application Notes

    Pulling in TECs into Ax with the Maxline driver and trying to get docs. Have application notes for everything but 2273 & 2274.

    Customer appears to have a 2273 HP app for a 2 stg DX, 2 stg elec...
  7. Replies
    7
    Views
    832

    Ah! Thanks! Boxed myself into the thought of...

    Ah! Thanks! Boxed myself into the thought of needing an "action" to manipulate it.
  8. Replies
    7
    Views
    832

    No, there are earliest start time and earliest...

    No, there are earliest start time and earliest stop time settings within the (VykonPro) OSS block that use AbsTime. Trying to figure out how to expose them.
  9. Replies
    9
    Views
    741

    Have you verified the configuration in the...

    Have you verified the configuration in the router? I'd would also try connecting to it locally at the JACE with a good patch cord and see if it comes online......would verify your Ethernet...
  10. Replies
    7
    Views
    832

    Tridium Custom Programs

    Was trying to find a way to write AbsTime into the OSS blocks for start & stop times to expose on graphic. Haven't seen a way yet, but I know there is a RelTime command block in the VykonPro module....
  11. Replies
    7
    Views
    603

    Seems that the weather.jars work for a while,...

    Seems that the weather.jars work for a while, then just crap out. We have had some 3.4.43 stations constantly re-boot because of an issue with this jar. There are alternatives. I believe google...
  12. Replies
    10
    Views
    822

    Thanks smmedlin! Found our TUNCOS logic and...

    Thanks smmedlin!

    Found our TUNCOS logic and NDIO point polling eating it up. Also, set the Non-Critical Flag for the runtime extensions.
  13. Replies
    10
    Views
    822

    E Series JACEs

    Seems to me that Honeywell's genius idea to eliminate the need of batteries is to have the unit constantly process data recovery and hog up resources. These JACEs are slow, slow, slow....

    Is...
  14. Gotta love DIY'ers......first off, JACE needs to...

    Gotta love DIY'ers......first off, JACE needs to be licensed for "LCDProgrammable". Is he able to access that palette and set-up comms?
  15. Replies
    26
    Views
    4,356

    I discovered as a dynamic device and converted...

    I discovered as a dynamic device and converted the XIF file from the lonmark site to lnml. Program IDs matched. Wouldn't commission in AX though, but was able to config online and bring it...
  16. Replies
    26
    Views
    4,356

    Digging up an old thread......but having similar...

    Digging up an old thread......but having similar problems here with the LCI-R card.

    I too noticed nciOAMinPos coming in as SNVT_temp_p, instead of SNVT_lev_percent. I also do not see any change...
  17. Replies
    5
    Views
    651

    The points are selected for view. I have several...

    The points are selected for view. I have several conditions that must be true before I enable a fan, yet I always have one or two of them giving me a -1 value instead of a 0.
  18. Replies
    5
    Views
    651

    I referenced Vern's Level II Webs class booklet. ...

    I referenced Vern's Level II Webs class booklet. He mentioned that in an XL10 controller, you have to write a non-zero value to each of the data fields for the point to actually turn on. Not true...
  19. Replies
    5
    Views
    651

    Sharing binary status on Spyders

    Hoping someone can help me out here...

    I created nvo and nvi by using NV Config view in the Spyder (set to SNVT_switch). I exposed the state on the wiresheet and linked my logic. Generated NVs. ...
  20. OK. Created a nvo (temp p)and linked it directly...

    OK. Created a nvo (temp p)and linked it directly to the physical point. Created a nvi (temp p) and lon linked like mentioned above on the lon network wiresheet. Link worked.

    I do not see...
  21. I did the conversion and it took care of the...

    I did the conversion and it took care of the error. I have a nvoOATemp point in the points list, but it still does not show up when I go to do the lon binding on the lon network wiresheet.
  22. Spyder Programming Help - OAT Sharing

    For the life of me, I can't get the process down on how to do this. Any help would be appreciated.

    I have an OA Temp Sensor on UI1. I generated NVs, then went to Lon Point Manager. Located UI1...
  23. Replies
    5
    Views
    551

    Thanks for clarifying that Sam. I know Echelon...

    Thanks for clarifying that Sam. I know Echelon recommends that on their network, but really didn't occur to me about doing the same for DIs.

    Our vendor recommended Citel DLA.
  24. Replies
    5
    Views
    551

    Thanks for the replies. Will try wiring the...

    Thanks for the replies.

    Will try wiring the closer buildings direct and go with the relay solution on the farthest.

    Osiyo, thanks for the controller operation explanation.
  25. Replies
    5
    Views
    551

    DI line length

    I have a medium sized facilty with three storage buildings. Two of them are roughly 250' away and the other is about 500' away. All I have to do in those three buildings is to monitor the status of...
  26. Replies
    2
    Views
    430

    Lon Gas Detection Devices

    Need for CO and NO2. Was planning on using a Honeywell XIO-8AI with the E3 Point sensors, but realized that definitely was not going to work. Any suggestions for sensors that can reside directly on...
  27. Replies
    2
    Views
    457

    I must be a slow learner.... I see the enum...

    I must be a slow learner....

    I see the enum proxy points but still have no idea how to switch over "the measured variable". I've tried action & set, but still shows resistance when I select...
  28. Replies
    5
    Views
    1,582

    Sounds like it came from the site "e-mails from...

    Sounds like it came from the site "e-mails from an a__hole" or something like that. Funny stuff.
  29. Replies
    0
    Views
    464

    Spyder Graphics

    Relatively new, so be kind.

    I have a simple lead/lag sequence in the programming. Created a PX view. I can simulate the programming by forcing values, but can't seem to get the PX to respond. ...
  30. Replies
    11
    Views
    1,383

    Never had to worry about that around here.... ...

    Never had to worry about that around here....

    What about using OAT & OAH sensors to determine if it is snowing?

    Is this what you currently have? http://www.networketi.com/19036.htm
  31. Replies
    9
    Views
    1,703

    Keep in mind Honeywell is not signing anyone new...

    Keep in mind Honeywell is not signing anyone new up for the R2 level as it will be obsolete in a couple years.
  32. Replies
    1
    Views
    501

    Surge/Lightning Protection

    Was just curious what everyone is doing here.

    I was told that Echelon recommends using gas-type like this. If a segment of the network is outside the building, every controller on the network...
  33. Replies
    36
    Views
    2,648

    I found this thread in a search for a...

    I found this thread in a search for a user-friendly solution. I downloaded EnergyPlus, but have been completely overwhelmed by its capabilities and manuals with thousands of pages.....
  34. Replies
    2
    Views
    365

    OK....newb figured out his problem :) 1. Was...

    OK....newb figured out his problem :)

    1. Was going about it wrong....

    2. Didn't matter anyway, since my workbench will not read 2.0 versions (R2).
  35. Replies
    2
    Views
    365

    Niagara Newb Request Some Help

    It's my first time hooking up to a customer's site and I cannot find the station.

    I'm hooked directly to the JACE-403 with a crossover cable. The IP, subnet mask, and the gateway and written on...
  36. Replies
    4
    Views
    477

    Crankcase heater is not likely to be your...

    Crankcase heater is not likely to be your problem.

    As far as blowing up the transformers, sounds like you have miswired the stat somehow and have created a short.

    Not likely to be getting any...
  37. As previously mentioned, your load has increased....

    As previously mentioned, your load has increased. Of course other conditions may contribute. How many windows? Any shading? Insulated?

    As far as your system goes, do you have a system capable...
  38. Replies
    2
    Views
    366

    The factory charge is likely to be written on the...

    The factory charge is likely to be written on the nameplate data of the outdoor unit. If not, it will definitely be in the tech manual. Usually no additional charge would be required for a 25'...
  39. Replies
    83
    Views
    19,517

    If you could add me to that list, that would be...

    If you could add me to that list, that would be great. Thanks.
  40. Thread: I'm done

    by CerealKiller
    Replies
    21
    Views
    1,472

    I'm with ya. I was raised in the country and I...

    I'm with ya.

    I was raised in the country and I couldn't get out of there fast enough. As I get older though, my tolerance for the flip side of city life is starting to weigh on me. When you have...
  41. Replies
    13
    Views
    1,146

    Thanks for the input. The units are only about...

    Thanks for the input. The units are only about ten years old and I wasn't sure if it would be the right thing to restore the equipment to original. I feel bad for the customer who paid for the...
  42. Replies
    45
    Views
    10,801

    Well, if it is a myth.......why do manufacturers...

    Well, if it is a myth.......why do manufacturers put in in their install manuals then?
  43. Replies
    13
    Views
    1,146

    Gutted Intellipak

    See attachment. Talk about taking the "Intelli" out of Intellipak. I guess the Alerton guys were not on good terms with Trane to pull points. :D

    Besides all the gutted boards, all 6 cans come...
  44. Replies
    45
    Views
    10,801

    Ideally, manufacturers recommend you install the...

    Ideally, manufacturers recommend you install the bulb on a horizontal surface. In this case, the piping should have been plumbed to allow that. Yes, you can install the bulb on a vertical...
  45. Replies
    45
    Views
    10,801

    It will not affect operation now, but the...

    It will not affect operation now, but the electrical tape will likely give way over time and the bulb will come loose. He really should have used the clamps that come with it. Do not use a regular...
  46. Replies
    45
    Views
    10,801

    Most definitely needs to be on a horizontal run. ...

    Most definitely needs to be on a horizontal run.

    As far as the placement, I've always been of the 4 and 8 o'clock school. If the manufacturer recommends 10 and 2 o'clock, well......that is...
  47. Replies
    26
    Views
    2,643

    I've just come across a similar problem with a...

    I've just come across a similar problem with a local church. They have a million+ dollar organ in this sanctuary and have humidity and major noise issues. The acoutics in the space is really good...
  48. Replies
    44
    Views
    2,289

    That just made my day. ROFL! :p

    That just made my day. ROFL! :p
  49. Replies
    44
    Views
    2,289

    Based on what? You had debris moving around...

    Based on what?

    You had debris moving around your system BEFORE he got there.

    You may be right though. A line shouldn't just rupture like that which means he did a less than stellar job with...
  50. One caveat I would like to add to that is....you...

    One caveat I would like to add to that is....you really need to monitor your nitrogen flow through a flow meter rather than a pressure regulator. Not that it can't be done (guilty myself) but it is...
Results 1 to 50 of 85