  1. Replies
    4
    Views
    167

    Have no idea? Are all DDC systems different? The...

    Have no idea? Are all DDC systems different? The one I dabble with now is a Metasys system.
  2. Replies
    4
    Views
    167

    DDC Training

    Hello guys,

    Been doing all this HVAC/R crap since I was old enough to carry my Dad's tools, but now I need to jump on the DDC bus before it passes me by. I have one DDC system I work on, but...
  3. Replies
    15
    Views
    591

    So compressors are up and running. Amped out ok...

    So compressors are up and running. Amped out ok and system pressures are ok. I told customer that compressors reset and operating but don't know what damage may have been caused and will note that on...
  4. Replies
    15
    Views
    591

    Most definitely new driers with a oil sample....

    Most definitely new driers with a oil sample. Gonna head over and check the system in a hour or so. Let everyone know happens
  5. Replies
    15
    Views
    591

    I'm anxious to see if these compressors will...

    I'm anxious to see if these compressors will restart today. Ither way there went warranty and my invoice will say need to replace

    Thanks guys
  6. Replies
    15
    Views
    591

    I watched my wording lol. People write they won't...

    I watched my wording lol. People write they won't run backwards which isn't true they will run backwards just won't work or "pump"
  7. Replies
    15
    Views
    591

    True dat. Ya I've always figured phase monitors...

    True dat. Ya I've always figured phase monitors should be on every system. Sparky should of known and checked or called us before he turned breaker on. Landlord gonna bill tenant and see if tenant...
  8. Replies
    15
    Views
    591

    I haven't seen what happens if running wrong...

    I haven't seen what happens if running wrong direction cus I always check so this will my first.

    That will be my suggestion PecMsg wether they restart or not
  9. Replies
    15
    Views
    591

    I was ****ting tweenkies for a few minutes on the...

    I was ****ting tweenkies for a few minutes on the roof, till I realized all the hot tubs they had in the store. I knew there had to be panel upgrades at that point and I didn't F up lol
  10. Replies
    15
    Views
    591

    Scrolls running wrong direction

    Gentleman,

    I'm wondering what the odds are that my two compressor will be ok after running wrong direction for a few days. I installed a Carrier 10 ton gas pack about a month ago, and then the...
  11. Crmont Do you know the Joghnstone #? I hate...

    Crmont

    Do you know the Joghnstone #? I hate that book, and sure as hell hate calling there even more lol. So manyyyyyyyyyyyyyyyyyyGV's in there. Thanks
  12. Can anyone tell me this valve manufacturer

    Can anyone tell me this valve maker of this silenoid valve, gas valve, safety valve? 120 v off a old wall furnace counterlow recessed furnace. I guess the main valve is a old modulating valve, has a...
  13. Replies
    3
    Views
    290

    Heat exchanger wasn't plugged, but restricted....

    Heat exchanger wasn't plugged, but restricted. Iced up. Was thinking that could of happened, and sure enough, had started to melt this am, and had water spraying out of the outlet before I got there....
  14. Replies
    3
    Views
    290

    dont see any and was worried bout that. Thought...

    dont see any and was worried bout that. Thought Id ask. Thanks bro
  15. Replies
    3
    Views
    290

    Open loop water furnace heat pump help

    Gentleman,

    Stopped by a call today, only had a few minutes to spare, headed back in am. I'm not a pro on water furnaces other than in heats and cools, and heck it's all the same, just takes longer...
  16. Replies
    0
    Views
    118

    18k LG Ductless match up help

    Gentleman,

    Working on a single zone LG Ductless a LMU185HV it's matched up with a single zone LMN185HV. Works great, ecspecially for a POS LG system. So it's a 2 port, and I checked match up chart...
  17. Replies
    11
    Views
    536

    Whats that Tim?

    Whats that Tim?
  18. Replies
    11
    Views
    536

    Ya it had RA and fresh air on display

    Ya it had RA and fresh air on display
  19. Replies
    11
    Views
    536

    Display just reads heat on. Doesn't say if it's...

    Display just reads heat on. Doesn't say if it's auxiliary or heat pump
  20. Replies
    11
    Views
    536

    Yes contractor is closed.

    Yes contractor is closed.
  21. Replies
    11
    Views
    536

    trane tracer system help

    Gentleman,

    On a call today, never worked on this Trane BAS system before. Probably isnt that hard besides Ive never worked on one. So its just a air handler and a heat pump. Heat pump and air...
  22. Called homeowner today haven't had a chance to go...

    Called homeowner today haven't had a chance to go back. Units working great since I stopped the recycling in combustion :) he praised me like I was god lol. I told him it was quick and easy and...
  23. Replies
    1
    Views
    209

    RSD located a damaged evap coil and found a...

    RSD located a damaged evap coil and found a orfice and installing today
  24. Replies
    1
    Views
    209

    Bohnmizer txv help

    Gentleman,

    Work on a Freezer Mac 6 unit at Mickey D's. Evaporator isn't being fed correctly so changed out the valve yesterday, and I noticed a previous contractor had worked on it prior to me. I...
  25. Instructions on this York FG9 says you can tie...

    Instructions on this York FG9 says you can tie coil condensate and furnace condensate together as long as coil drain is trapped upstream