Search:
Type: Posts; User: htrguy
Search: Search took 0.01 seconds.
-
05-17-2013, 08:58 AM
Thread: New Rheem Furnace video
by htrguy- Replies
- 4
- Views
- 253
Baldloonie Where did you get the instructions?
Baldloonie
Where did you get the instructions? -
05-15-2013, 09:42 AM
Thread: New Rheem Furnace video
by htrguy- Replies
- 4
- Views
- 253
Heres more stuff...
Heres more stuff
http://www.apiofnhanddeltat.com/linked/rheem_90_plus_new_furnace.pdf -
05-15-2013, 09:36 AM
Thread: New Rheem Furnace video
by htrguy- Replies
- 4
- Views
- 253
New Rheem Furnace video
http://www.gormanindustries.com/Rheem_High_Impact_360PlusOne_WMV.wmv
-
01-08-2009, 09:59 AM
- Replies
- 20
- Views
- 717
I had one just last week. Fan and condenser...
I had one just last week. Fan and condenser seemed fine. High head only problem. Just for fun I used a strobo tach on the fan and it was running way to slow. Changed the motor/capacitor and bingo all...
-
01-08-2009, 09:51 AM
- Replies
- 20
- Views
- 717
Fan
Keep it simple
Outdoor fan not turning fast enough. Motor shot; dirty condenser -
01-11-2008, 04:00 PM
Thread: Recommendations For Replacement Gas Pack
by htrguy- Replies
- 8
- Views
- 1,529
Dual Fuel
Have you considered a Dual Fuel unit? Rheem makes a RQPW that is 14SEER and 8+ HSPF with a gas backup when the HP cant keep up. Other companies make one but I don't know the model #
-
12-11-2007, 05:27 PM
Thread: Rheem Mod Airflow
by htrguy- Replies
- 6
- Views
- 679
What a bizzare request. The unit is designed to...
What a bizzare request. The unit is designed to operate at a given temperature rise in heat. You want to override that to overcome a bad duct layout. A consideration is that would take a unit out of...
-
12-10-2007, 03:00 PM
Thread: Log Home Manual J
by htrguy- Replies
- 2
- Views
- 470
I have used R-3 per inch of log with success....
I have used R-3 per inch of log with success. There is a delay in the transfer of heat so the peaks change. In my opinion it has more to do with lowering the (or raising) the design temperature. The...
-
11-29-2007, 09:16 AM
Thread: Best Dual Fuel system?
by htrguy- Replies
- 11
- Views
- 2,238
Basically there are two versions of gas heat. An...
Basically there are two versions of gas heat. An 80% furnace and a 90+ furnace. The reason there is not a 85% furnace is the flue gasses start condensing at that range and the heat exchangers have to...
-
11-26-2007, 11:40 AM
Thread: Best Dual Fuel system?
by htrguy- Replies
- 11
- Views
- 2,238
None work with both gas and heat pump operating...
None work with both gas and heat pump operating at the same time. On package units the heat pump coils are before the gas heat exchanger. The hot air off the heat pump will make safety switches trip...
-
11-21-2007, 04:09 PM
Thread: Rheem mod classic questions
by htrguy- Replies
- 20
- Views
- 1,763
I need to re-state that the 22 code is an open...
I need to re-state that the 22 code is an open limit. When the limit opens it will shut off the gas and keep the blower on until it re-sets. I would only expect to see it during a gas heat call and...
-
11-21-2007, 03:03 PM
Thread: Rheem mod classic questions
by htrguy- Replies
- 20
- Views
- 1,763
The yellow wire on the thermostat should be on Y....
The yellow wire on the thermostat should be on Y. The yellow wire on the furnace should be on YH/Y2.
11 is four failed ignitons. Could be someone left the gas valve shut off.
22 is a failed... -
11-14-2007, 12:26 PM
Thread: Rheem mod classic questions
by htrguy- Replies
- 20
- Views
- 1,763
That yellow wire is sticking too far out and...
That yellow wire is sticking too far out and almost or is hitting a resistor. Your installer should be careful to not stick the wires out too far.
-
10-16-2007, 12:16 PM
Thread: RUUD Modulating furnaces
by htrguy- Replies
- 52
- Views
- 5,825
Rez You could just post your own thread with a...
Rez
You could just post your own thread with a title like "How I hook up a Mod stat"
Seem like you want to be sure everyone see's this. -
10-08-2007, 11:36 AM
Thread: Packaged Gas Furnace and A/C Systems?
by htrguy- Replies
- 37
- Views
- 2,352
Rheem has SS standard in their dual fuel unit and...
Rheem has SS standard in their dual fuel unit and it is an option on all others. The dual fuel RQPW would be my choice. 14 SEER 81% furnace 8.2 HSPF. Looks effiicient enough for me, better than alot...
-
08-13-2007, 09:30 AM
Thread: Service Normal?
by htrguy- Replies
- 13
- Views
- 1,281
I guess my point is that I like this field of...
I guess my point is that I like this field of work but I hate to clean up other people's messes. This is the part I hate that this customer paid for the work and tried to keep up on the maintenence...
-
08-10-2007, 12:28 PM
Thread: Service Normal?
by htrguy- Replies
- 13
- Views
- 1,281
To be honest, I rally didn't feel like cleaning...
To be honest, I rally didn't feel like cleaning the evaporator and the suction pressure was still good. It was late and hot and I told him it needs to be done but I just didn't feel like doing it...
-
08-10-2007, 11:55 AM
Thread: Service Normal?
by htrguy- Replies
- 13
- Views
- 1,281
Service Normal?
I, like everyone else, have been on several emergency calls lately that have gotten under my skin.
A classic example
Guy calls hot in his house and says he need more freon (classic). I go over... -
07-24-2007, 09:06 AM
Thread: EER vs. SEER
by htrguy- Replies
- 6
- Views
- 1,655
What I posted is how it is calculated by the ARI...
What I posted is how it is calculated by the ARI standards, by manufacturers.
If a unit is sized for a given load it will run almost continuosly during peak periods of energy usage at the efficency... -
07-23-2007, 11:57 AM
Thread: EER vs. SEER
by htrguy- Replies
- 6
- Views
- 1,655
Is that your rule of thumb. Kinda like 1 ton for...
Is that your rule of thumb. Kinda like 1 ton for every 400 sqft.
-
07-23-2007, 10:23 AM
Thread: EER vs. SEER
by htrguy- Replies
- 6
- Views
- 1,655
The label EER is measured at 80 indoor air 95...
The label EER is measured at 80 indoor air 95 outdoor air running continuosly.
The label SEER is measured by using an EER (not related to the label EER) measured @ 80 indoor and 82 outdoor and... -
07-09-2007, 09:57 AM
- Replies
- 28
- Views
- 20,987
I sold a home last year that was in a flooded...
I sold a home last year that was in a flooded market with alot of similar homes, some that had much better locations. Mine was on a corner with high traffic and a steep hill to mow on one side. I had...
-
06-25-2007, 09:54 AM
Thread: SEER vs. EER calcs
by htrguy- Replies
- 2
- Views
- 3,802
EER is capacitiy divided by watts at the set...
EER is capacitiy divided by watts at the set indoor and outdoor conditions of 80 dry bulb 67 wet bulb indoor and 95 outdoor temperatures. SEER is taking the EER on low speed compressor (if available)...
-
06-19-2007, 09:11 AM
Thread: No show/ no man J
by htrguy- Replies
- 14
- Views
- 1,065
Huh?
Huh?
-
06-05-2007, 09:31 AM
Thread: Upstairs is Warmer than Downstairs
by htrguy- Replies
- 26
- Views
- 5,558
It's been said already but I just have to chime...
It's been said already but I just have to chime in. In a two story or multiple story home the home will stratify by roughly 2° if the floors have any shared or open areas in common like a cathedral...
Results 1 to 25 of 204