    It looks like carrier has gone the way of hyper...

    It looks like carrier has gone the way of hyper complicating troubleshooting to the point that all one can do is guess and Pay big money for parts that don't need to be replaced.

    If they wanted...
  2. Thread: DIY Comedy

    by kjkircher
    Replies
    18
    Views
    5,540

    Sounds like you know how to make a "standin...

    Sounds like you know how to make a "standin landin".
  3. Replies
    25
    Views
    5,370

    You don't understand... This unit, lineset,...

    You don't understand... This unit, lineset, cutoff box and probably even the pad came off of new construction at about 11:pm one night.

    This is what it looks like when you do a smash install at 2...
  4. Thread: DIY Comedy

    by kjkircher
    Replies
    18
    Views
    5,540

    Duct tape on the wingtip reminds me of many of...

    Duct tape on the wingtip reminds me of many of the choppers plastered w "go fast" tape in Nam.

    Don't knock it til you've tried it. . .
  5. Thread: Randoms...

    by kjkircher
    Replies
    8
    Views
    2,374

    Lint Clogged Coil is VERY common. More...

    Lint Clogged Coil is VERY common. More manufacturers should put inspection/access door in the box.

    I have considered putting a plexiglas plate in my properties evap boxes to see the dirty side of...
  6. Replies
    4
    Views
    800

    Mine over six years too and it is very accurate....

    Mine over six years too and it is very accurate. Easy fix on the vac pump is to take case apart, reconnect the tube and/or spray motor w silicone lube. Also, the batteries will develop a memory...
  7. Replies
    3
    Views
    728

    Thanks for the response. I am just trying to...

    Thanks for the response.

    I am just trying to see through all the smoke and mirrors of the refrigerant recovery system manufacturers. They advertise that by using their expensive systems you can...
  8. Replies
    3
    Views
    728

    Refrigerant Recovery

    Assume that the charge in a system is contaminated with Air and water vapor.

    When this is evacuated from the system and compressed into the recovery cylinder, what happens to it?

    The filter...
  9. Replies
    50
    Views
    4,613

    Make Sure the Ridge Vent on roof has been...

    Make Sure the Ridge Vent on roof has been properly installed and make sure thermostat on attic blower is properly set. Ditto on separating the attic load via proper placement of returns(insulate them...