  1. Actually, I retract my statement. I just...

    Actually, I retract my statement. I just remembered something. This sports club has their technicians work on the a/c units. Their techs are there to fix all the work out equipment, not the a/c...
  2. The funny thing is that it came from the factory...

    The funny thing is that it came from the factory like that :beat:
  3. Replies
    17
    Views
    2,527

    Thank you very much! I forgot to upload the after...

    Thank you very much! I forgot to upload the after shots, but next time I'm back at the location I will take some. The bad thing is that this club has their workout equipment technicians work on the...
  4. Must have been a buy one get two free day at the supply house.

    You can never have enough flex line. 465411
  5. It's still on the wooden pallet that it was...

    It's still on the wooden pallet that it was shipped with haha. The holes are there. They were just to lazy to remove it from the wood.
  6. Them there are running boards for the compressor stand

    This was a first for me. Saw this on a new customer's condensing unit.368821
  7. Replies
    6
    Views
    1,029

    Just to clean up the wire, a little less than an...

    Just to clean up the wire, a little less than an hour. The whole job took about a week. That includes the whole re wire and installing controls. New 10 hp motor, shaft, wheels, bearings, and...
  8. Replies
    6
    Views
    1,029

    Overload relay fire continued

    Sorry for starting a new thread. I could not figure out how to post pictures on a reply to my last thread. Here is this job finished up. The first picture is of my work station for a couple days. The...
  9. I felt like retrofitting the unit to a 90's era...

    I felt like retrofitting the unit to a 90's era lennox with all the red wire :whistle: haha. I picked up a roll of red to make up for what I could not get of ready made wiring harnesses from Lennox....
  10. Thanks everyone!

    Thanks everyone!
  11. Looks like your overload relay caused a small fire

    This is a Humiditrol for a Pool area at a sports club. The blower motor shorted, and caused the overload relay to burn up. Which in turn caused a "small" fire in the electrical compartment. This was...
  12. Leave it up to the in house maintenance crew

    I was servicing a unit that's dedicated just for a pool pump and equipment room. I noticed this while working on the air handler. Just to the left of the picture is a 10 hp motor that supplies air to...
  13. Replies
    9
    Views
    1,366

    Maybe the PVC used in the picture is suffering...

    Maybe the PVC used in the picture is suffering from vertigo?:whistle:
  14. Anything stopping or restricting airflow on the...

    Anything stopping or restricting airflow on the flue pipe? I've found huge hornet nests in those things a couple times. Luckily they were all dead when I began to do the heat start up. Have you been...
  15. Replies
    25
    Views
    3,058

    I did a lot of walgreens roof replacements last...

    I did a lot of walgreens roof replacements last year for the company that I work for. We had to install these on all the new units, and if the old units had them we had to reuse them. They're...
  16. Replies
    7
    Views
    2,221

    I bet that's RTU #5! :whistle: Just a guess, but...

    I bet that's RTU #5! :whistle: Just a guess, but Trane? Just becuase the brackets that support the condenser fan motor.
  17. Replies
    85
    Views
    17,527

    I've replaced more headers on Trane voyagers than...

    I've replaced more headers on Trane voyagers than the Carrier 50HJs. 3 to 4 of orifices plug up. Either way it's the same procedure Six posted pictures of. Just take your time and don't let it get...
  18. Replies
    17
    Views
    2,893

    I know some people like to leave a signature or...

    I know some people like to leave a signature or hand prints in wet concrete, maybe the unit wanted to do the same thing then realized it was stuck.
  19. Replies
    24
    Views
    4,105

    I agree 100%

    I agree 100%
  20. Replies
    6
    Views
    1,670

    haha duh that's the filter temperature sensor!

    haha duh that's the filter temperature sensor!
  21. Replies
    1
    Views
    557

    I know this reply is a bit late, but no...

    I know this reply is a bit late, but no conversion board is needed. Each unit should be tied in through your system bus terminals on the top of your A56 board for the NCP. Under the ECTO parameters...
  22. Replies
    15
    Views
    2,773

    That's when you tell the Home owner what CFC...

    That's when you tell the Home owner what CFC stands for... coil free cooling!
  23. Replies
    7
    Views
    1,525

    It seems by the brochure the 900 comes with a gun...

    It seems by the brochure the 900 comes with a gun :grin2:
  24. Replies
    31
    Views
    5,291

    I live in the metroplex too, and will keep a look...

    I live in the metroplex too, and will keep a look out. Did you initial or put your name on your tools? I hope you get them back soon. It's the worst when something in taken from you.
  25. Replies
    8
    Views
    1,867

    This is more than likely your cause. It's a 3...

    This is more than likely your cause. It's a 3 wire bi metal switch. I believe the unit you're working on only has one. You should only have continuity between the two adjacent wires. If you have it...