  1. If you feel the wk badge, you will feel two holes...

    If you feel the wk badge, you will feel two holes behind the label. When they get badged Rheem, they poke those holes out and press in a Rheem plastic Badge that has to snap locks that fit into the...
  2. Any installer who can see a 5% change raise your...

    Any installer who can see a 5% change raise your hand..... I didnt think so.

    So on a 60,000 btuh furnace... 1% is 600 btuhs.... it's nothing more than a slow opening valve. By the way its the same...
  3. Replies
    51
    Views
    7,141

    You cant read the duty cycle with a meter. You...

    You cant read the duty cycle with a meter.

    You will have to read the milli-amp signal to the gas valve or measure the gas pressure. the signal from the thermostat is a PWM signal. The milli-amp...
  4. Replies
    13
    Views
    3,279

    same goes for the Rheem mod furnace and 16 seer...

    same goes for the Rheem mod furnace and 16 seer heat pump. It sets itself up too if you set it up as a communicating system (much like the infinity). Doesnt matter, you still have to compare apples...
  5. Replies
    51
    Views
    7,141

    By setting the thermostat up 1 degree, you will...

    By setting the thermostat up 1 degree, you will not see a 40% firing rate. You will have to wait until it works it's way up or works it's way down to the 40% firing rate. Unless your meter measures...
  6. Replies
    13
    Views
    3,279

    It's still not apples to apples. The Carrier...

    It's still not apples to apples. The Carrier system proposed is a dual fuel system and the Rheem is not, why not ask for a dual fuel Rheem set up so you have the same options?
  7. Crap, I didn't see that... funny. I need to pay...

    Crap, I didn't see that... funny. I need to pay better attention. Although how pleasing is it to hear from a member three years later to hear she is thrilled with her decision after consulting...
  8. Replies
    23
    Views
    2,596

    Sorry, I missed your response there. I have a...

    Sorry, I missed your response there.

    I have a Rheem Modulating gas furnace as the air mover and back up.

    The JEZ is still in some warehouses so it would be unwise to pretend it doesnt exist....
  9. Replies
    8
    Views
    2,507

    Good thing you wouldn't find a burner for it...

    Good thing you wouldn't find a burner for it anyway.
  10. Bald, Since when did you forget you can...

    Bald,

    Since when did you forget you can control humidity with a mod thermostat?
  11. Yeah, dirt in the blower is exclusively a Rheem...

    Yeah, dirt in the blower is exclusively a Rheem thing
  12. Replies
    17
    Views
    2,507

    No "Smart heat" from Carrier is a fancy way of...

    No "Smart heat" from Carrier is a fancy way of saying "watt resistor". The watt resistor limits the amount of electric heat coming on when the return temp is warm. (keeps your watts down, hence the...
  13. Replies
    4
    Views
    5,392

    If you expect anything to be exhausted you need...

    If you expect anything to be exhausted you need to supply some fresh air.

    I made the mistake of putting a spa in a room before... Besides, there's nothing better than sitting in a spa with snow...
  14. Replies
    19
    Views
    1,129

    Haha :payattention:

    Haha :payattention:
  15. Replies
    9
    Views
    607

    last time I shorted a thermocouple, the earth...

    last time I shorted a thermocouple, the earth turned backwards. You may not have noticed it, but you did have a de ja vu as a result.
  16. Replies
    18
    Views
    9,307

    Get another tech or tell your tech to find help...

    Get another tech or tell your tech to find help from his distributor service coordinator.

    The fact is that the mfg specified the strict vent tables for a reason and the reason has nothing to do...
  17. Replies
    4
    Views
    494

    I'm not sure what this is in regard to, my memory...

    I'm not sure what this is in regard to, my memory is short.
  18. Replies
    63
    Views
    3,673

    I dont always agree with Robo. But in this case I...

    I dont always agree with Robo. But in this case I do. These two cats could have been picking up a unit as subs or employees of a licensed contractor. The fed ex-guy just dropped off some stuff in a...
  19. Replies
    10
    Views
    799

    That's the key. In today's furnaces, I would...

    That's the key. In today's furnaces, I would rather the homeowner not be opening the blower/control cabinet for obvious reasons. The installer should definitely make the effort to make the filter...
  20. Replies
    23
    Views
    2,596

    I have the RPRL-036JEC and yes, if you are...

    I have the RPRL-036JEC and yes, if you are willing to kick out the bucks, get the 550 stat. I have that as well on mine. You do need to tell your tech you want the serial communicating system.

    You...
  21. Replies
    15
    Views
    1,351

    so now look closely at your vent system and drain...

    so now look closely at your vent system and drain if it's a condensing furnace (drain may be slow).
  22. Replies
    19
    Views
    2,425

    my guess the capacitor on the board is weak that...

    my guess the capacitor on the board is weak that supports the spark. Have them order yo a new board (dont take from stock).
  23. Replies
    8
    Views
    1,847

    Clopay, you will need the AHRI certification for...

    Clopay, you will need the AHRI certification for your specific system, not just the outdoor unit. Once the system is installed, post the full model numbers of both the indoor unit and outdoor unit...
  24. Replies
    23
    Views
    2,596

    The two options are probably a 21" air handler...

    The two options are probably a 21" air handler and a 17" air handler. Either that or the air handler ends in JA or JC. Since they carry different model numbers on the air handler, they require...
  25. Replies
    51
    Views
    4,381

    The flip flop occurred when HX all became...

    The flip flop occurred when HX all became negative pressure. You could take a modern furnace and drill holes in it and not produce carbon monoxide in the house. For safeties sake, I would trash any...