  1. Replies
    4
    Views
    1,966

    Thanks, actually its very stable. We mounted a 5"...

    Thanks, actually its very stable. We mounted a 5" caster wheel to the bottom of the tank so it has full support.
  2. Replies
    4
    Views
    1,966

    Our Latest Creation...FRANKENFILTER!

    I thought a few people might find this interesting.
    We have a group of customers with several open drive compressor racks between them and oil costs are becoming a concern.
    (between them there is...
  3. Replies
    27
    Views
    6,103

    The best bet is to consult a mechanical engineer....

    The best bet is to consult a mechanical engineer. If you dont know of one, the guys we use are also licensed in Alberta. For the roughly $1000.00 (just a guess based on previous jobs) that they...
  4. Replies
    27
    Views
    6,103

    If its easier for you, my email is in my profile....

    If its easier for you, my email is in my profile. Feel free to communicate by email as well. (I dont think we are allowed to put email addresses in posts)
  5. Replies
    27
    Views
    6,103

    The manufacturer specs 1 unit/3 welding stations...

    The manufacturer specs 1 unit/3 welding stations but in Manitoba we require 1500 cfm/welding station.
    Local code will supersede depending on where your located but if your requirements are similar...
  6. Replies
    27
    Views
    6,103

    What are you doing in the building? Is it a...

    What are you doing in the building? Is it a welding shop, manufacturing, etc. Any plasma cutting or other activities that produce smoke or contaminants?
  7. Replies
    27
    Views
    6,103

    There is no limitation to the shop size at all....

    There is no limitation to the shop size at all. We have had very good success with them with zero complaints or issues to date. The shop in these pictures is aproximately 60x90 if I remember right. ...
  8. Replies
    132
    Views
    4,141

    I have personally serviced houses on a reserve...

    I have personally serviced houses on a reserve west of winnipeg that are 1500 square feet plus on the main floor with fully finished basements and would be $300g homes in any community. I am also not...
  9. Replies
    132
    Views
    4,141

    I have seen lots of good ones too. But in...

    I have seen lots of good ones too. But in Manitoba for every good "native" there are 20 useless "indians". When you work on any of the reserves you see just how much they appreciate what...
  10. Replies
    17
    Views
    3,373

    You bet. We have been using UV dye in those...

    You bet. We have been using UV dye in those systems for a few years. It works great.
  11. Replies
    17
    Views
    3,373

    We added an external oil cooler to this system a...

    We added an external oil cooler to this system a couple weeks ago. Here are some pics.
    http://i117.photobucket.com/albums/o71/jlaffradi/Jamors%20Mycom%20Swap/IMG00368-20101102-1401.jpg...
  12. Replies
    41
    Views
    7,086

    Thanks, These units are all R-404A. I think the...

    Thanks, These units are all R-404A. I think the head cooling fans and oil coolers are standard equipment on the low temp Bohn equipment but im not 100% sure.
    We actually havent put in much for 22...
  13. Replies
    17
    Views
    3,373

    But why would a 45 be any more prone to failure...

    But why would a 45 be any more prone to failure than a 90? Interesting for sure. Just to be safe I will throw a couple extra pipe supports on tomorrow. Doesn't take a whole lot and its cheap...
  14. Replies
    17
    Views
    3,373

    The transducer that you can see is the suction...

    The transducer that you can see is the suction temperature sensor. They mount directly into the compressor on the Sabroes but there isnt any provision for that on the Mycoms. The pressure transducers...
  15. Replies
    17
    Views
    3,373

    I personally have never had a problem with 45's...

    I personally have never had a problem with 45's yet. I had someone bring that up once before and I was not able to find anything showing that 45's are any weaker than a 90 but if you know something...
  16. Replies
    17
    Views
    3,373

    We feel open drive is a better option in these...

    We feel open drive is a better option in these places because the compressors are fully rebuildable and there is also no chance of refrigerant contamination due to burnout. (Some of these systems...
  17. Replies
    41
    Views
    7,086

    Actually we had Rick Vandenberg from DOL do it...

    Actually we had Rick Vandenberg from DOL do it for us. We do a fair bit of control panels and usually get him to do them. Rick lives in Morden so it is pretty handy. Where are you from Frostie?
  18. Replies
    41
    Views
    7,086

    Thanks, the guys did an awesome job on this one...

    Thanks, the guys did an awesome job on this one and the customer was really impressed and happy. Anytime people from another colony come over he makes sure to show them lol
  19. Replies
    17
    Views
    3,373

    Finally Almost done. Just a tiny bit of...

    Finally Almost done. Just a tiny bit of electrical and final alignment to go.
    http://i117.photobucket.com/albums/o71/jlaffradi/Jamors%20Mycom%20Swap/IMG00299-20101005-1700.jpg...
  20. Replies
    17
    Views
    3,373

    That laser alignment tool is freakin awesome....

    That laser alignment tool is freakin awesome. Alignments that used to take me 5-6 hours now take less than an hour with tighter tolerances. We used to shoot for .004" misalignment or better and now...
  21. Replies
    17
    Views
    3,373

    Sabroe To Mycom Open Drive Swap

    This is the same system that we just installed a new 80 ton condenser on. (Another thread in this section)
    We are switching away from Sabroe compressors and moving to Mycom due to Sabroe parts...
  22. Replies
    74
    Views
    7,696

    I really like that trap idea. I will definitely...

    I really like that trap idea. I will definitely be changing the way I pipe oil traps from now on. I have a 60ton condenser going in next week so I will try it on that one.
    Like I said, we have piped...
  23. Replies
    74
    Views
    7,696

    Just like Supertek said, we are cutting the...

    Just like Supertek said, we are cutting the condenser in half in low ambient.
    We have 15 stages of unloading on the rack. Say we are down to temperature and they shut one shed down to wash product...
  24. Replies
    74
    Views
    7,696

    On a semi related note, we are starting to prep...

    On a semi related note, we are starting to prep these systems for changing over to HFC's from R-22.
    We started using POE oil 3 or 4 years ago in place of Alkylbenzene. I was originally going to...
  25. Replies
    74
    Views
    7,696

    Freebird I just reread your post, why would your...

    Freebird I just reread your post, why would your boss not allow 45's?? Also the part that is critical about pressure drop is that flow through each circuit is identical.
    Dowadudda which part dont...