  1. I think putting in an NIE is better than nothing...

    I think putting in an NIE is better than nothing and I'll help with migration to MSEA. If your PMI workstation dies you're not totally blind. You don't NEED your workstation but you'll want to keep...
  2. Replies
    9
    Views
    1,437

    In most cases you will not need to change the...

    In most cases you will not need to change the wall stat. They come with a nice wiring harness. To be honest my opinion is the #1 drawback is your programming and commissioning it with CCT and some...
  3. Replies
    29
    Views
    3,163

    I'll agree with simux some what.. just make sure...

    I'll agree with simux some what.. just make sure your NAE55 you're buying is a NAE55xx-1 (or preferable -2) ... no reason to screw yourself over with a -0
  4. You could still do this yourself. Granted of...

    You could still do this yourself. Granted of course it's recommended to call a controls tech out but you can't screw it up too much more than it is unless you NUT it and loose power or disconnect in...
  5. Unfortunately you're probably going to have to...

    Unfortunately you're probably going to have to get it NUTed. The customer doesn't have a Metasys disk? Look for Network Update Tool... And the appropriate image.
  6. Replies
    2
    Views
    810

    Only if you're running Ready Access Portal...

    Only if you're running Ready Access Portal (ADS-Server-Name/metasysrap instead of /metasys) it's free with the newer versions of Metasys ADS/X .. It's not the same as the full SMP but you can monitor...
  7. Replies
    13
    Views
    1,336

    Sam, Interesting reply; a good read. I don't...

    Sam,

    Interesting reply; a good read. I don't know every aspect of the RS-485 protocol nor do I ever really plan to learn it so I can't argue on what it "is" and I am sure you could offer PDF...
  8. Replies
    13
    Views
    1,336

    RS-485 is a two wire protocol. JCI modified it to...

    RS-485 is a two wire protocol. JCI modified it to a 3 wire system to expand the devices. While its loosely RS-485 it really isn't and that's why they can use 64 (or 100) devices on the bus. I would...
  9. Replies
    11
    Views
    924

    The Control System are in the website directory...

    The Control System are in the website directory under N50... A DOS search of a name of one of the interlocks will assist you in finding them if they aren't rolled into a database.
  10. Replies
    6
    Views
    612

    How do you have access to CCT6 already? Our BPPs...

    How do you have access to CCT6 already? Our BPPs are back ordered.. I imagine we'll get them in a week or two. Beta site?
  11. Replies
    5
    Views
    549

    I have a bunch of these at one of my sites......

    I have a bunch of these at one of my sites... Just integrate it through N2 ... The liebert is RS-232... The integrator has a special table loaded to do translation. You'll have to know what the n2...
  12. Well I am not surprised they don't roll out the...

    Well I am not surprised they don't roll out the red carpet; who is with competition? I'm sure they would be happy to be contracted to do the work. You should be integrating the chiller with e-link...
  13. Replies
    11
    Views
    924

    I misinterpreted your post originally.. Are you...

    I misinterpreted your post originally.. Are you talking about writing a program that you can re-use or a one time (manual) command like all the responses you've gotten so far? There is access to...
  14. I'd say at least a quarter of my ADX installs are...

    I'd say at least a quarter of my ADX installs are on VMs right now for the redundancy. I only ever run into the normal issues (permissions).
  15. Replies
    12
    Views
    848

    Just echoing the last post; I have a site with a...

    Just echoing the last post; I have a site with a few large UPSes. We integrate through sitelink by BACnet/IP... On the older ones we have integrators (MIG). And a few talk BACnet/MSTP... They were...
  16. Replies
    3
    Views
    524

    Besides the other tips you can also use that...

    Besides the other tips you can also use that little box in the N2 troubleshooting guide (can be found on JCI quicklit or just google for it)... It'll work the same on BACnet. It's only. Handful of...
  17. All variable in most cases.. Condenser, chiller...

    All variable in most cases.. Condenser, chiller compressors, primary and secondary chiller water loops... It depends on the equipment you have (and what you're generally replacing) on how much you're...
  18. There is nothing confidential about CPO30. It's a...

    There is nothing confidential about CPO30. It's a product anyone can have engineered into a design for them. I simply made some suggestions about ensuring there was enough "meeting" time in their...
  19. I have helped out on one; contact me off list.

    I have helped out on one; contact me off list.
  20. Replies
    9
    Views
    878

    I work for JCI and have been offered jobs with...

    I work for JCI and have been offered jobs with other controls companies and at a few sites; I wouldn't leave unless is was a ridiculous amount of money. A couple guys in our shop are Siemens and...
  21. Replies
    16
    Views
    2,761

    Uninstall then Re-install Java. Start with the...

    Uninstall then Re-install Java.
    Start with the newest version and work backwards. You should only have the newest compatible Java on the PC that Metasys (at whatever version you're running)...
  22. Replies
    16
    Views
    2,761

    Okay, My next step would be to delete the Java...

    Okay,
    My next step would be to delete the Java temporary files in Control Panel > Java under the temporary Internet files section (settings button) those are XP directions, win7 may be different...
  23. Replies
    16
    Views
    2,761

    It's possible that are a different 'Object...

    It's possible that are a different 'Object Category' (General/HVAC/Power/etc.) an that user doesn't have access to that category as defined in the security administration. Also check to ensure...
  24. Replies
    16
    Views
    2,761

    Berg2666, sounds like they are running Ready...

    Berg2666, sounds like they are running Ready Access Portal. It's the only way to view Metasys on Firefox.
  25. Thread: Metasys bus

    by chas_md
    Replies
    17
    Views
    1,213

    HVACPro is not very Windows 7 friendly; It's not...

    HVACPro is not very Windows 7 friendly; It's not supported. That being said it runs on many Windows 7 machines (including JCI tech laptops) but I've also seen plenty of machines it will not run on....