    Bet what's screwing the system up is either the...

    Bet what's screwing the system up is either the filter drier that's probably located inside the condenser, or the cap tubes running from the txv valve are partially blocked. In the future when you...
  2. Check your coil outside and make sure its clean....

    Check your coil outside and make sure its clean. What I would do is recover the refer't, cause it sounds like you have a leak somewhere anyway. Your system is low on charge to begin with, take apart...
  3. Replies
    5
    Views
    530

    I like my imperial set ( 5 years old and just...

    I like my imperial set ( 5 years old and just recently rebuilt them). Is that the digital set by field piece your talking about ? The more complicated things are made the more aches they are.
  4. Thread: TXV???

    by canusayinsanity
    Replies
    28
    Views
    2,025

    Equalizer tube is to unload pressures in coil...

    Equalizer tube is to unload pressures in coil from high side to low side when a/c operation turns off. This is to prevent overloading compressor on start up when theres a call for cool.
  5. Replies
    17
    Views
    1,221

    And yes start bottom joint on vertical txv first....

    And yes start bottom joint on vertical txv first. A little extra prep time and thought takes less time than to do whole procedure over again.
  6. Replies
    17
    Views
    1,221

    I find that its easier to braze one end at a time...

    I find that its easier to braze one end at a time on a txv. I spray the power head and body with cool gel , careful not to get on the joints, I'll braze one end. Take wet rag and wrap around txv body...
  7. Replies
    50
    Views
    3,107

    Wow that's crazy KB cool, about the 10ton...

    Wow that's crazy KB cool, about the 10ton circuits mixed up lol
  8. Replies
    37
    Views
    3,497

    Recently I've heard many companies trying to...

    Recently I've heard many companies trying to enforce a predetermined amount of time it should take you to replace components not taking into consideration the difficulty level. Every job is different...
  9. Replies
    37
    Views
    3,497

    I've been doing this for only 8 years now and I'm...

    I've been doing this for only 8 years now and I'm tired of getting bent over myself. Companies have no appreciation for your efforts. I used to work crazy hours and kill myself. till my back started...
  10. Replies
    67
    Views
    5,110

    You are correct timebuilder. You will always get...

    You are correct timebuilder. You will always get voltage at the other where your common is supposed to be connected. 230,120,24v and so on. Resistance of coil will not degrade expected supply...
  11. Replies
    35
    Views
    2,440

    Sounds like a restriction. Not too familiar with...

    Sounds like a restriction. Not too familiar with them, worked on em and fixed em but not a fan of em. Someone should chime in soon that has better knowledge of that unit. If I were you I'd get down...
  12. I've been down that road of matching splits, in...

    I've been down that road of matching splits, in my opinion your better off sticking to the same tonnage. Otherwise your gonna open a can of worms that you really don't wanna eat. Also take into...
  13. Replies
    67
    Views
    5,110

    Either you lost the 24v. Common or your getting...

    Either you lost the 24v. Common or your getting 24v. on both low volt wires to the contractor. Disconnect both and test each wire to ground making sure your reading zero on the common side.
  14. Replies
    611
    Views
    102,917

    The company has a client that has several stores,...

    The company has a client that has several stores, complete pain in the arse. It was 85 ot the other day
    And manager said a/c worked perfectly ( nice and cool). Yeah right. Found 2 new furnace and a-...
  15. Replies
    35
    Views
    2,720

    I will say that the ability to inspect and clean...

    I will say that the ability to inspect and clean the inside area of a coil is an issue, makers definitely don't make it easy access. They have a removable plate but how ya supposed to get it past the...
  16. Id check the ifc board for burn marks on the...

    Id check the ifc board for burn marks on the back. Sounds like low volt is dropping out for a split second, to quick to notice with meter. I does sound like board is screwed. P.s. fault code,...
  17. In these cases I usually break out my hook n rope...

    In these cases I usually break out my hook n rope and scale the side of the building. Throw on my harness with my broken lanyard from a similar job that I had fallen off the roof, its still good....
  18. Replies
    8
    Views
    642

    I'd probably cut the hs line - pinch n cap off....

    I'd probably cut the hs line - pinch n cap off. Keep gauges hooked up, service valves open on condenser and cycle. See if hs psi goes up immediately, if it builds slow or nothing at all then its...
  19. Replies
    7
    Views
    787

    Oh yeah, you found your problem. Anything acidic...

    Oh yeah, you found your problem. Anything acidic will destroy any unit you put in, electric or gas. You have to get rid of the sulfuric problem first.
  20. Replies
    7
    Views
    658

    I'd definitely soak up all residual fuel before...

    I'd definitely soak up all residual fuel before attempting to light again.
  21. If he's been adjust the limit switch which I'm...

    If he's been adjust the limit switch which I'm assuming he talking about high limit ( heat mode) then there's more troubles. Sounds like old helix coil fan limit= possible cracked heat exchanger....
  22. Replies
    15
    Views
    1,325

    Pretty much pick up everything these guys have...

    Pretty much pick up everything these guys have mentioned. Harder to get the stock going but easier to maintain in the future.
  23. Replies
    22
    Views
    1,722

    Lmao!! The cheek? Man that sucked.

    Lmao!! The cheek? Man that sucked.
  24. Replies
    42
    Views
    3,275

    I seen that one too but counter Guy was a little...

    I seen that one too but counter Guy was a little skeptical on its performance.
  25. Replies
    10
    Views
    1,037

    I agree with sac, just keep enough stocked on the...

    I agree with sac, just keep enough stocked on the truck.