Search:

Type: Posts; User: JumpSteady

Page 1 of 12 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thanks for all the input. Got it going.

    Thanks for all the input. Got it going.
  2. Never mind. Found 134a sticker on evaporator

    Never mind. Found 134a sticker on evaporator
  3. what gas does this walk in take from pressures

    Found and fixes leak. Can anyone tell me what gas this walk in Cooler takes from these pressures?

    Condenser fan cut in 200 diff. 35

    Compressor cut in 28 diff. 20
    High pressure cut out 350...
  4. Replies
    53
    Views
    7,482

    I like.

    I like.
  5. Replies
    198
    Views
    29,130

    I just wanted to be sure it wasn't some weird...

    I just wanted to be sure it wasn't some weird proprietary size battery, thanks.
  6. Replies
    198
    Views
    29,130

    I am thinking about getting an sman2 or sman3. ...

    I am thinking about getting an sman2 or sman3.

    What kind of battery does it run on?
  7. Replies
    5
    Views
    992

    Just don't reach down and accidentally unscrew...

    Just don't reach down and accidentally unscrew the regular hose from the adapter while connected to a unit. Seen another tech do that, lose 7 lbs of refrigerant and pretty bad frostbite.

    Just...
  8. Thanks. :)

    Thanks. :)
  9. cant see pics and posts are in reverse order

    When I'm not logged in I can see pictures. But when I am logged in it shows a link and you have to click on the link to see pics. Also when I look at a thread it shows the last posted message...
  10. Replies
    50
    Views
    10,156

    Fluke 16 my frontline meter, but I have an...

    Fluke 16 my frontline meter, but I have an Amprobe ACD-10 Plus I use for amps. I like it, mostly. I don't like it takes CR2032 batteries. I'd rather worry about keeping just 9 volts for my fluke,...
  11. Replies
    161
    Views
    52,000

    No. I only have one, don't have anything to...

    No. I only have one, don't have anything to compare it to. It seems to work as it should.
  12. Replies
    161
    Views
    52,000

    I've been using a Yellow Jacket 69080 Digital LCD...

    I've been using a Yellow Jacket 69080 Digital LCD Vacuum Gauge. It has bars that go from 500 to 750 to 1000, etc. I like it. It seems to work well enough.
  13. Replies
    6
    Views
    643

    Yeah robinair has red and blue too. But I don't...

    Yeah robinair has red and blue too. But I don't think the color has any significance.
  14. Replies
    20
    Views
    3,806

    My friend has used the robinair 15500 5 cfm...

    My friend has used the robinair 15500 5 cfm Vacumaster for many years. It still pumps down fine. But the switch did go out on it and he replaced it with a different switch. Personally I would have...
  15. Replies
    50
    Views
    10,156

    Still using my old fluke 16. I tried to use my...

    Still using my old fluke 16. I tried to use my friends fieldpiece one day on an electrical problem. Going down a breaker panel trying to locate a certain circuit, we had the wires twisted together...
  16. Replies
    35
    Views
    4,270

    That sounds good. My CLC is past due for...

    That sounds good. My CLC is past due for replacement.
  17. Replies
    5
    Views
    941

    You have no idea! My before pics were actually...

    You have no idea! My before pics were actually after I precleaned it with the shop vac. That's why you can even see the coil fins in a few spots before I pressure washed it.
  18. Replies
    5
    Views
    941

    Most mobile homes don't have an outdoor spigot. ...

    Most mobile homes don't have an outdoor spigot. So you can't use a hose. I can use this with a 5 gallon bucket and siphon kit if there is no spigot, as was in this case. Actually the only thing...
  19. Replies
    5
    Views
    941

    Maxi Vac Mini Max

    Been using this a couple years now. Works great. Thought I would finally get around to taking some pictures and video.

    Haven't bought any nasty chemicals since I got this. I only use water to...
  20. Yes it had power. It would try to start and the...

    Yes it had power. It would try to start and the overload would click.
  21. I can't say why, but it is my understanding it...

    I can't say why, but it is my understanding it runs off the mainboard. I guess I'll find out when I replace the board.
  22. The start start relay/run cap tested good. The...

    The start start relay/run cap tested good. The condenser fan motor was not running because of defective mainboard. I believe over time this killed the compressor.
  23. Yeah I agree. Thanks.

    Yeah I agree. Thanks.
  24. Yes that I did. It came with the new compressor...

    Yes that I did. It came with the new compressor kit, and I would change the filter dryer on any system with a compressor change out.
  25. I only put a fitting on the low side, in the...

    I only put a fitting on the low side, in the process tube. But I see your point. I'll try that next time, thanks.
Results 1 to 25 of 297