Search:

Type: Posts; User: kermy

Page 1 of 3 1 2 3

Search: Search took 0.00 seconds.

  1. Replies
    10
    Views
    1,247

    kermy, This is the Ask Our Pro's forum. In...

    kermy,

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a...
  2. Thread: Fun AC Story

    by kermy
    Replies
    20
    Views
    1,893

    So true! Next time I have this dilemma, I'm...

    So true! Next time I have this dilemma, I'm going to ask them to fill a large glass with water. Then I'm going to say you have 2 seconds to drink it all... when they can't, I'll ask them if they...
  3. Replies
    7
    Views
    1,654

    What kind of unit is that where they still run...

    What kind of unit is that where they still run the refrigerant lines through the cabinet?? I HATE those!
  4. Replies
    26
    Views
    6,578

    Bet if you tossed a fire cracker in the...

    Bet if you tossed a fire cracker in the exchanger...
  5. Replies
    19
    Views
    4,342

    Geez! Just wrap it with some solid strand 10...

    Geez! Just wrap it with some solid strand 10 gauge copper wire and be done with it LoL!
  6. Replies
    6
    Views
    1,082

    The tech who diagnoses your problem with that...

    The tech who diagnoses your problem with that unit needs to have good knowledge of Lennox equipment. Could be a venting problem, a draft inducer problem, board problem, flame sensor problem, or...
  7. Well they're gonna have to have an onboard...

    Well they're gonna have to have an onboard speaker on those non-clicking thermostats so the technician will be able to hear when it calls... kinda like the click on camera phones... lol
  8. Replies
    11
    Views
    2,683

    Ok, some of those sensors have to have a special...

    Ok, some of those sensors have to have a special shielded wire ran from them to the thermostat... If that's not the problem, your sensor might be bad. Must ohm the wires open and then with sensor...
  9. Thread: blower motor

    by kermy
    Replies
    11
    Views
    683

    The problem is the furnace is wet;) Wait for it...

    The problem is the furnace is wet;) Wait for it to completely dry before trying to use it again.
  10. Replies
    24
    Views
    4,128

    Think wind blowing through trees. That there...

    Think wind blowing through trees. That there filter is too good for your return design. Also, alot of people do not realize how having a 'good' expensive filter can make unfiltered air more...
  11. Replies
    6
    Views
    2,169

    No, they have never gotten stuck to where it...

    No, they have never gotten stuck to where it blows out the charge in the hose for me. But sometimes the pressure pops the o-ring out, and sometimes damages it, and you have to ease it back into it's...
  12. Replies
    21
    Views
    3,222

    I bet if there were a designated oriface for the...

    I bet if there were a designated oriface for the bulb to go into, it would always be installed properly. LMAO
  13. That's a Square Dead box isn't it?

    That's a Square Dead box isn't it?
  14. Replies
    67
    Views
    5,818

    I think your tech knows what's wrong;-)

    I think your tech knows what's wrong;-)
  15. Replies
    19
    Views
    1,297

    So THAT"S why the bottles are pink!! 410A...

    So THAT"S why the bottles are pink!! 410A systems are ultra sensative.
  16. Replies
    19
    Views
    1,297

    I've noticed that it's much more difficult to...

    I've noticed that it's much more difficult to spot a problem on a 410A TXV in the earliest stages of it's failure. Pressures are so close to what they are supposed to be! Most of the time for us,...
  17. Replies
    11
    Views
    1,677

    Awesome! I remember a few Rheem package units...

    Awesome! I remember a few Rheem package units LAYING on top of the unit soldering in a compressor, suction and liquid line driers and such UPSIDE DOWN because there wasn't room to 'get in'. I'd...
  18. Replies
    24
    Views
    4,753

    This has been my experience.

    This has been my experience.
  19. Replies
    6
    Views
    1,087

    Perhaps they changed out the 'guts' and left the...

    Perhaps they changed out the 'guts' and left the old coil box with the original data sticker?
  20. Ask them about the TXV.

    Ask them about the TXV.
  21. Replies
    2
    Views
    380

    Call an electrician!!!

    Call an electrician!!!
  22. If only they could make a condenser look like a...

    If only they could make a condenser look like a tree, maybe people would stop trying to hide them...
  23. Replies
    6
    Views
    1,363

    Dick Cheney must work in that office.

    Dick Cheney must work in that office.
  24. Thread: HRUMPH,....

    by kermy
    Replies
    30
    Views
    4,207

    Ma'am, were gonna have to schedule your tune-up...

    Ma'am, were gonna have to schedule your tune-up for tomorrow! lol
  25. Replies
    25
    Views
    2,430

    The elecricians always put the darn disconnect in...

    The elecricians always put the darn disconnect in a bad place when the high voltage wire comes out of the wall like that. And I can see the unit used to sit alot closer to where the lineset exits...
Results 1 to 25 of 60
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event