  1. Thread: YCAV

    by hvac1966
    Replies
    1
    Views
    646

    YCAV

    working on some york variable speed screw machines anyone with any service related issues on these machines !!!
  2. Replies
    2
    Views
    1,084

    high co readings

    Took a call on a small trane precedent roof top roll out switch was open and would not reset. Changed the roll out switch lit off the unit observe the flame ok , the low stage burned at high 02...
  3. Thread: too hot

    by hvac1966
    Replies
    9
    Views
    699

    too hot

    I have a 208/230 volt rooftop when the mercury was jumping out of the thermometer at 104 deg, the measured voltage was 190 volts at the unit. I'm curios 208 230 +/- 10% acceptable lower than the 208...
  4. Replies
    14
    Views
    1,611

    ????

    I thought that as well your trying to displace oxygen also to reducing the oxidation scaling on the inside of the pipe.????
  5. Thread: Capacitor ?

    by hvac1966
    Replies
    33
    Views
    1,696

    BLA BLA BLA BLA, PAY THE BILL MOVE ON , I CANNOT...

    BLA BLA BLA BLA, PAY THE BILL MOVE ON , I CANNOT BELEIVE PEOPLE WOULD WASTE THERE TIME ANSWERING THIS POST
  6. Replies
    2
    Views
    458

    19xrv oil heater seal ring

    Any one change one of these looking for degree of difficulty, looks like you have to pull oil pump & cooler???????
  7. Replies
    15
    Views
    1,311

    if it's a newer home check out chinese drywall !!!

    if it's a newer home check out chinese drywall !!!
  8. Thread: carrier 19xrv

    by hvac1966
    Replies
    3
    Views
    1,645

    carrier 19xrv

    Carrier centrifugal with pic 2 control, this one sounds relativly simple, doing the winter maint on this machine and noticed a phase reversal fault nothing had changed elecrically, reset and back...
  9. Thread: transformers

    by hvac1966
    Replies
    3
    Views
    695

    transformers

    Why do we groung the secondary of a control transformer( stepdown transformer). Any veiws on this would be appreciated .
  10. Replies
    21
    Views
    1,240

    Thank you moose i hadn't heard of the strap on...

    Thank you moose i hadn't heard of the strap on heaters , had thought of doing that though. I do not now what the first stage reg is orificed for, that is the propane dealers reg . I am learning alot...
  11. Replies
    21
    Views
    1,240

    The totel load is !million 6 hundred thousand ,...

    The totel load is !million 6 hundred thousand , the line size leaving the tank farm is inch and one hallf,Tha line size is oversized for the load.The pressure leaving the first stage reg is 10 psi...
  12. Replies
    21
    Views
    1,240

    Two ,thousand gallon tanks, the tanks are icing...

    Two ,thousand gallon tanks, the tanks are icing up I would think that might be somewhat normal as the propane is vaporizing. All the calculations that where done suggest that the first stage reg is...
  13. Replies
    21
    Views
    1,240

    propane applications

    I have a job using propane to serve 4 rtu's and 4 unit heaters.New installation , the problem is the line pressure drops from 10 psi to 6 inches when i bring some load on. I have a first stage and...
  14. Replies
    18
    Views
    2,283

    oversizing heating systems ???? never heard of...

    oversizing heating systems ???? never heard of that ...
  15. Replies
    18
    Views
    2,283

    I have a two stage furnace in my home just...

    I have a two stage furnace in my home just installed beginning of fall. I have a single stage stat, amd allow the high stage to cycle based on time. I pulled out a lennox atmospheric burner at...
  16. Replies
    23
    Views
    3,162

    Measure the air temp !!! is it too high ???...

    Measure the air temp !!! is it too high ??? Plugged ac coil, problem with zoning system, ductwork, Damper... Can you traverse the ductwork to check your airflow???? Is my gas pressure too high...
  17. Replies
    14
    Views
    1,635

    Have you ever seen the damage that can occur to...

    Have you ever seen the damage that can occur to personal property and body, when boilers are not serviced by qualified proffesionals. Call a pro!!!! This is not blowing smoke, this is people actually...
  18. Replies
    17
    Views
    2,145

    send it out for analysis, it sounds like you were...

    send it out for analysis, it sounds like you were the only person servicing it. Ive seen some synthetic oils used by people, royal purple i think was one.
  19. Replies
    1
    Views
    399

    high efficiency gas furnaces

    I just installed a two stage 95 percent efficiency furnace, in my house ,most of my work is on the commercial and industrial side. I am curious as to problems with acidic condensate disposal, do...
  20. Thread: carrier 19xrv

    by hvac1966
    Replies
    3
    Views
    766

    carrier 19xrv

    Have a 19xrv that has been off most of the summer . Went to start it and getting drive fault overcurrent? motor never attempted to start ? the drive is a reliance ref cooled drive. I cannot even...
  21. Replies
    17
    Views
    1,269

    I would go with the 5 ton, and do your ductwork...

    I would go with the 5 ton, and do your ductwork necessary for the larger system, it sounds like the old system could not keep up, good luck
  22. Replies
    18
    Views
    4,731

    could be, and if it is that simple if you wher to...

    could be, and if it is that simple if you wher to have somebody proffesional look at it , would most likely be a simple fix
  23. Replies
    18
    Views
    4,731

    16 stories i would have to assume you have a...

    16 stories i would have to assume you have a central chilled water plant in the building. So there also may be some type of ventilation air introduced also, wich could affect humidity lvels if not...
  24. Replies
    9
    Views
    1,412

    I would have a pro do the air balancing report...

    I would have a pro do the air balancing report for you, then continue with your troubleshooting. High suction could mean a few things, too much airflow, high return temps !!! , compressor efficiency...
  25. anyone come up up with any interesting ways to...

    anyone come up up with any interesting ways to disable the gps in your service vehicle ????