  1. Replies
    4
    Views
    1,409

    Dash--- Filters are 20 x 20. Total CFMs are 1200...

    Dash--- Filters are 20 x 20. Total CFMs are 1200 for cooling and 1050 for heating (3 ton heatpump). I had a thought that additional 1 inchers would provide a better chance of catching the dirt that...
  2. Replies
    4
    Views
    1,409

    On this Trane Variable Speed Air Handler model...

    On this Trane Variable Speed Air Handler model TWE037E13FB, highboy, upflow, there is a vertically positioned Electro-Air electronic air cleaner. I have recommended removal of the cells due to...
  3. Replies
    0
    Views
    969

    Is brownout protection (ICM 206) recommended for...

    Is brownout protection (ICM 206) recommended for this Trane 3 ton heatpump model TWY036B100A1? Or, is only anti-short-cycling timer (ICM 203) necessary? It has single stage scroll compressor.
  4. Thread: Trane Heatpump

    by marca
    Replies
    17
    Views
    4,414

    Thank you all for your replies! Regarding my...

    Thank you all for your replies! Regarding my Trane 3 ton heatpump model TWY036B100A1, could you please let me know if this unit was manufactured with an anti-short cycling timer installed in the...
  5. Replies
    30
    Views
    8,516

    I have newer Trane heatpump (XL1400) with...

    I have newer Trane heatpump (XL1400) with matching coil and variable speed air handler, and resistance heat strips. I want a thermostat, that in heat mode, will slowly ramp-up (in 2 degree...
  6. Replies
    6
    Views
    4,248

    Heatpumps -- Despite what is commonly...

    Heatpumps --

    Despite what is commonly mentioned in this forum, I agree 100% with your conclusion regarding setting back thermostat for heatpumps. However, as was mentioned in this thread, people...
  7. Thread: Trane Heatpump

    by marca
    Replies
    17
    Views
    4,414

    Filterchanger -- Yes, if both heat sources are...

    Filterchanger -- Yes, if both heat sources are operating simultaneously, plenum temp. will be much higher. However, if second stage kicks in, meaning that there was a 2-3F drop that called first...
  8. Thread: Trane Heatpump

    by marca
    Replies
    17
    Views
    4,414

    mfb-- I wholly agree! Based on my personal...

    mfb-- I wholly agree! Based on my personal experience, there is a point of "diminishing returns" when running the heat pump in very cold weather as contrasted to shutting it down and activating the...
  9. Thread: Trane Heatpump

    by marca
    Replies
    17
    Views
    4,414

    1. I had 2 Trane heat pumps (installed May 2002),...

    1. I had 2 Trane heat pumps (installed May 2002), model TWY036B100A1 (3 ton) and they are coupled with the Trane variable speed air handler and matching coil, model TWE037E13FB. I believe that the...