    wow!! guess jork has really gone downhill, glad i...

    wow!! guess jork has really gone downhill, glad i left 4 years ago. so nice now to take about 5 mins at the end of the day, hit one button and be done. fire up the laptop, check email, and my...
  2. Replies
    16
    Views
    2,663

    don't let the metasys control it.....the only...

    don't let the metasys control it.....the only thing that controls is the price of the BAS contract which has no high limit cutout on it!!! one of the mcquays i have in nashville on metasys has only...
  3. Replies
    4
    Views
    634

    if ever replacing that seal again, would highly...

    if ever replacing that seal again, would highly recommend some dow 111 on them o-rings....keeps the rigor mortis out for a while. and the seal pressure, well, i would recommend at least 4 psig at...
  4. Replies
    37
    Views
    3,845

    just isolate the purge, cut it off and install a...

    just isolate the purge, cut it off and install a trane purifier purge.....simple. i've installed too many purifiers behind the redi's and won't even present that as an option to my customers anymore....
  5. Replies
    13
    Views
    1,127

    they are all great when they're running and you...

    they are all great when they're running and you do an inspection and they are all even better when they crash and the customer says just get it running!! oh, and how good is this, there is a york ot...
  6. Replies
    6
    Views
    770

    ammonia is very efficient but very hard to work...

    ammonia is very efficient but very hard to work with. can't use any copper otherwise it eats it up. it is very good for low temp applications i.e. dry ice manufacturing. if it gets on you, yes it...
  7. Replies
    8
    Views
    555

    on the YT's it doesn't matter how many hertz the...

    on the YT's it doesn't matter how many hertz the machine is running at to set oil pressure on the seal, they gots the oil press reg valve on 'em. i know the factory is going to recommend some high...
  8. Replies
    12
    Views
    1,406

    i would have a weld-o-let put on and run all the...

    i would have a weld-o-let put on and run all the lines in copper. got at least a dozen of these machines and all but 3 are copper. well, they will be eventually. just run the lines slightly larger...
  9. Replies
    45
    Views
    3,602

    i wouldn't want to be the person who gave you the...

    i wouldn't want to be the person who gave you the professional status and read that one.:eek:
  10. Replies
    29
    Views
    1,839

    just a wild guess here, but i would look at the...

    just a wild guess here, but i would look at the actual valve here.....had to have replaced 5 of them over the years on yt's...not yk's. different valves with seals and yes the rubber seal in the...
  11. Replies
    15
    Views
    2,860

    mikey...how did you get to be a professional...

    mikey...how did you get to be a professional member? you're rses do that? scary thought....hehehe!! find a manual yet?
  12. Replies
    15
    Views
    2,860

    yo mikey......the only thing i think that needs...

    yo mikey......the only thing i think that needs attention is the transmission outside the ea/eb teardown goodies. better get some plastigage to reassemble it there bigga boy! hehe! remember the...
  13. Replies
    22
    Views
    2,993

    ahhhh, the glorious Z compressors.....good luck...

    ahhhh, the glorious Z compressors.....good luck with the oil pump. york, when they went from the J to the Z, they used the same oil pump but forgot to re-engineer just what you found...the tang not...
  14. Replies
    21
    Views
    3,807

    3 to peek at...the leaving chilled water sensor...

    3 to peek at...the leaving chilled water sensor usually right at barrel, the saturated evap sensor on bottom of evap barrel and the last is suction temp sensor in the suction line just a foot or two...
  15. Replies
    5
    Views
    865

    personally, i would recalibrate it and check the...

    personally, i would recalibrate it and check the new position against the reference position noted from the factory. if it is really close to the minimum of 35 mils, i would pull the charge and check...
  16. Replies
    208
    Views
    29,375

    it's amazing to see the turnabout with Jork. 18...

    it's amazing to see the turnabout with Jork. 18 years ago when i got in, it was very difficult to do so and took alot of work to stay. it was a privilege to service the York chillers. man have times...
  17. Replies
    10
    Views
    1,064

    trane rtaa which is 22 or the rtac which is 134a....

    trane rtaa which is 22 or the rtac which is 134a. jork air cooled scrolls suck.....and i mean suck. support and service is excellent with trane and good with carrier, but if i had a choice, go with...
  18. Replies
    11
    Views
    2,506

    last TM 1 i saw was 15 years ago in a hospital...

    last TM 1 i saw was 15 years ago in a hospital that replaced all three machines with new one. wish i would've saved parts. anywho.....about the only thing to do is call all the offices and see if...
  19. Replies
    39
    Views
    3,879

    as a former jork guy, and speaking about the...

    as a former jork guy, and speaking about the local branch, i'd rather have......well, i wouldn't recommend them. as a current trane guy, they are very professional and living up to every promise they...
  20. Replies
    16
    Views
    2,833

    not to get picky here, but feel free to call york...

    not to get picky here, but feel free to call york factory and talk to either dave saylor or steve baer (he"s the one who actually designed the board) and see what they say.
  21. Replies
    39
    Views
    3,879

    i think a lot of the older guys, 55 plus, need to...

    i think a lot of the older guys, 55 plus, need to take the younger guys under their wings and train them. at 21, i had two seasoned guys of 60 plus take me and mold me. it was a lot of crap to take,...
  22. Replies
    16
    Views
    2,833

    you can reset the acc count with that procedure...

    you can reset the acc count with that procedure but to clear the map requires an admin code.....trust me, been through that with dave saylor up at york factory many a time. to reset some of the run...
  23. Replies
    16
    Views
    2,833

    would love to give one out, but what is it needed...

    would love to give one out, but what is it needed for? i really don't want to be like the factory, but the only real necessity for it is to clear the acc map, and the problems with that need to de...
  24. Replies
    16
    Views
    2,833

    Yes, it depends on the date and type of panel,...

    Yes, it depends on the date and type of panel, one-line micro or the optiview. Careful with date temporary thingy...it may not work...tried it and sometimes it does and sometimes doesn't, haven't...
  25. Replies
    41
    Views
    3,396

    as a side note, scale for L.U. 43 here about...

    as a side note, scale for L.U. 43 here about $23.50, after I pay my own insurance I am still over $30.