  1. Replies
    9
    Views
    246

    seen 1/4' copper run along the top of a coil like...

    seen 1/4' copper run along the top of a coil like a trane rooftop and let the water trickle down as the fans suck in the air.when I was out in California and the roof temps would hit 120F they...
  2. Replies
    14
    Views
    508

    first off...with the unit off no power the return...

    first off...with the unit off no power the return air should be open with the outdoor air closed in front of the filter rack.loosen the rod knuckles and make sure they swing freely separated from...
  3. Replies
    7
    Views
    427

    want to see a sight....big time cheating going...

    want to see a sight....big time cheating going on! a shop full of OEM techs taking the first EPA tests when they first were issued in 93'...it was open book and some guys still failed..going out the...
  4. Replies
    1
    Views
    159

    James Garner....cool actor

    the Rockford Files was a great series,movies The Great Escape and 36 Hours http://www.youtube.com/watch?v=yg1Cx26-928
  5. Replies
    0
    Views
    167

    Trane LIC looking for JOURNEYMAN 638B

    it is the IR career site not the actual office so don't bother calling....go on the TRANE career site or CL skilled New York City for links
  6. Replies
    25
    Views
    753

    local companies will grab them and cover the...

    local companies will grab them and cover the warranty if the price is right put up the mod/sn and brand or try this site to list it.. http://www.bid-on-equipment.com/Category/HVAC+Equipment.htm
  7. i'm not a Labor Day flag toting walker like the A...

    i'm not a Labor Day flag toting walker like the A fitter guys are told to do,but did anybody ever hear of a union guy *****in' about the pay,beenies,new trucks and the new construction opps doing...
  8. companies that run Midnight to 8am service techs?

    looking to see if this a common thing now with techs working 8 hours other then the normal 8AM to 4:30PM grind.company in my area is looking for a midnight to 8 guy to cover jobs.it's not the...
  9. plus the union contract gets redone every 3 years...

    plus the union contract gets redone every 3 years with bumps in that hourly along with bennies...and that hourly match to every hour you work into that pension
  10. Replies
    4
    Views
    272

    maybe standing around with a lead engineer but...

    maybe standing around with a lead engineer but actually working on them and taking a watch with them on line you need a license..FDNY walks in on your watch with no ticket you will be fined.they flip...
  11. Thread: Move to union?

    by maxster
    Replies
    58
    Views
    1,661

    the way you talk to these guys at the sitdown...

    the way you talk to these guys at the sitdown will determine the journeyman/apprentice question.if they need a lead tech asap you will be scaled or over and out in a truck you go and the hell who...
  12. Thread: TRAIN Chiller

    by maxster
    Replies
    7
    Views
    235

    if it is a semi hermetic check the superheat from...

    if it is a semi hermetic check the superheat from the bottom of the suction valve at the compressor your flooding back verify CCH off in run/on in OFF
  13. Thread: Move to union?

    by maxster
    Replies
    58
    Views
    1,661

    you'll go in as a journeyman with a apprentice to...

    you'll go in as a journeyman with a apprentice to learn from you and no questions asked.your experience will kick in and they will see on your work invoices the proof..they will throw you into jobs...
  14. Replies
    4
    Views
    272

    you have to get a hi pressure license then work...

    you have to get a hi pressure license then work on them to accumulate time.if you worked on large chillers for say TRANE doing service and repairs it means nothing to a refer license.you need to get...
  15. PTACs are the easiest way to cool off condos,and...

    PTACs are the easiest way to cool off condos,and the biggest compaint is the fan noise hi at night with a compressor running anything except an exact slide in there is a waste of time...
  16. 24control wire in a brown wrapped with multicolor...

    24control wire in a brown wrapped with multicolor thin insulated wires within...BELL WIRE for stats to unit runs??
  17. the lead time on those types of repairs will go...

    the lead time on those types of repairs will go into the fall Sears and or KMART don't want to spend money on the rooftop stuff..how about the energy managment cycling the supplky fans off the...
  18. Replies
    10
    Views
    542

    anything below 5K microns is moisture if your...

    anything below 5K microns is moisture if your reading 1000 you can't have a leak it would of never got that low..sucking air in even on connections or hoses not holding the vac
  19. Replies
    19
    Views
    1,382

    if you were uneasy move on don't look back it is...

    if you were uneasy move on don't look back it is your future also.....so go with the gut feeling...next time take it from a Friday thru a weekend and think it over...knee jerking and quitting is a...
  20. throw in the related Sears Auto Centers for...

    throw in the related Sears Auto Centers for dogged out equipment,then save yourself for the KMARTs who owns SEARS what an operation.forget the maint guys they don't know where the roof is and heads...
  21. Replies
    29
    Views
    1,582

    get a pack of Robinair 5 ft'rs and dedicate them...

    get a pack of Robinair 5 ft'rs and dedicate them to vacs only and an inline ball valve shut off...never trusted the ones on the pumps to do a standing test.
  22. Replies
    29
    Views
    1,582

    anything under 1000 microns is moisture...charge...

    anything under 1000 microns is moisture...charge it 134A oil holds moisture on a pipe up.so your looking at moisture with the micron not going below 1000 not a leak .anything below 5K is moisture to...
  23. Replies
    28
    Views
    890

    and how hot is that LL if the heat isn't going...

    and how hot is that LL if the heat isn't going out on the condensers... and you pulled a good micron test ...
  24. there is a S Cali guy willing to train on the...

    there is a S Cali guy willing to train on the jobs here right now..check it out
  25. Replies
    17
    Views
    746

    take note on that return air temp going across...

    take note on that return air temp going across the evap with the panels on high RA should jack that suction a bit might be low on Freon...also the liquid line??? just out of the condenser to "the...