Search:

Type: Posts; User: waterdawg

Page 1 of 7 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    8
    Views
    186

    Should have check valve yes but you could just...

    Should have check valve yes but you could just shut off valve for summer
  2. Well you can get SH at condenser, that would...

    Well you can get SH at condenser, that would narrow it down a bit. Yes you should have ran, now you own it!!! how are filters being replaced? can you get a camera in there, not that will help. If you...
  3. Thread: work fatigue

    by waterdawg
    Replies
    19
    Views
    812

    😳 well Cap you may want to start thinking exit...

    😳 well Cap you may want to start thinking exit plan lol. Try 53!!! Actually I have been lucky enough to be able to spend time in field as well as behind a desk. The desk thing is nice when the ladder...
  4. Replies
    26
    Views
    708

    We go through soffit all the time on existing...

    We go through soffit all the time on existing houses. Slimduct all outside lines. Guys do a great job. We just did an century old heritage home with 4 units and 12 heads that made it into a bunch of...
  5. Thread: work fatigue

    by waterdawg
    Replies
    19
    Views
    812

    I hear ya Cap! I'm falling apart like a WalMart...

    I hear ya Cap! I'm falling apart like a WalMart shirt!!! Every year gets a bit harder, hotter, and longer!!
  6. Thread: TXV Issues!!

    by waterdawg
    Replies
    12
    Views
    640

    Sorry about typing! Small phone, big fingers lol!

    Sorry about typing! Small phone, big fingers lol!
  7. Thread: TXV Issues!!

    by waterdawg
    Replies
    12
    Views
    640

    Ok so update to the txv issue!! Had to more that...

    Ok so update to the txv issue!! Had to more that were overcharged yesterday. The units are again ADP but I think emerson valves this time lol. How long do you have to wait for these micro channel...
  8. Replies
    15
    Views
    541

    In saying that if its exposed we change...

    In saying that if its exposed we change it.....always!
  9. Replies
    15
    Views
    541

    Opps sorry yup smaller lol. So just the last part...

    Opps sorry yup smaller lol. So just the last part of the question? Most of our units are 3/4 and most existing are the same. I did call about a 30' that was 5/8 and unit was 3/4, they said it would...
  10. Replies
    15
    Views
    541

    Are you finding that the lines are smaller than...

    Are you finding that the lines are smaller than is required. Have you consulted with manufacturer as to wether or not the smaller size is ok?
  11. Thread: TXV Issues!!

    by waterdawg
    Replies
    12
    Views
    640

    We have had that as well but this is an actual...

    We have had that as well but this is an actual txv issue. Not to say its not our fault though re: purging, etc. just trying to establish if we are the only ones. That would narrow it down to us lol.
  12. Thread: TXV Issues!!

    by waterdawg
    Replies
    12
    Views
    640

    TXV Issues!!

    Having huge problems this year with ADP coils with parker valves. I've had 6-7 fail after a week and 1-2 fail on startup. They will either stick closed intermittently or never open. I have tried to...
  13. Replies
    29
    Views
    1,243

    Actually it leads to costly follow ups for us...

    Actually it leads to costly follow ups for us lol. Every job we do is inspected by me and if not right Its fixed. Its been a great program in that quality has improved 10 fold. It cost lots to do but...
  14. Replies
    24
    Views
    540

    Ok last time, sorry OP! Why yes I have! :) Again...

    Ok last time, sorry OP! Why yes I have! :) Again never saw an R410 system get close with proper airflow. All I said was they are not required. If you are arguing that they are necessary then you are...
  15. Replies
    24
    Views
    540

    Also I will not debate this on someone else's...

    Also I will not debate this on someone else's thread any longer. If you still want to discuss it PM me. If you do find documents that actually say it is required post them and yes i will admit I am...
  16. Replies
    24
    Views
    540

    When the system is in defrost the pressures will...

    When the system is in defrost the pressures will never reach 600!! Its in cooling and the evaporator is cold, put your gauges on and you will see this! You are lucky to get 150 on suction and maybe...
  17. Replies
    24
    Views
    540

    So lets clarify lol. You cycle the burner when in...

    So lets clarify lol. You cycle the burner when in defrost? Defrost terminates and now you keep heat pump off till plenum temp drops? Not sure how you do this. Got a wiring diagram? And yes typically...
  18. Replies
    24
    Views
    540

    Yup pretty much what I said lol. Do you have...

    Yup pretty much what I said lol. Do you have documents that say sensor is reqhuired? I use to put them on but all manufactures I talked say no. Is it a good ideal, i guess but as stated there is a...
  19. Replies
    24
    Views
    540

    Ummm sorry but you are wrong. There is a terminal...

    Ummm sorry but you are wrong. There is a terminal on outdoor unit that is typically marked w/66 (york) this terminal sends 24 to w or w1 at furnace when heatpump is in defrost so yes I guess its not...
  20. Replies
    24
    Views
    540

    They work great but you still need to add a relay...

    They work great but you still need to add a relay and if mounting a fan center it is very easy to override limit through feed back on fan line. Again unless you know what your doing dont do it. I've...
  21. Replies
    24
    Views
    540

    Well actually they can and do run at the same...

    Well actually they can and do run at the same time! When there is a defrost call the oil will be allowed to operate. But to OP you need someone that knows what their doing!
  22. Thread: Bryant txv

    by waterdawg
    Replies
    99
    Views
    3,993

    Sorry meant to quote superpro ^^^^

    Sorry meant to quote superpro ^^^^
  23. Thread: Bryant txv

    by waterdawg
    Replies
    99
    Views
    3,993

    Wow!!! Heat getting to you man!!! Oh and we don't...

    Wow!!! Heat getting to you man!!! Oh and we don't say retarded anymore we say special lol. Perhaps you need to read the post a bit more closely. I thought that was kind of humorous actually.
  24. Replies
    29
    Views
    1,243

    Also with the scroll being used more and more its...

    Also with the scroll being used more and more its really not a great ideal to pump them down. If it happens to go into a vacume you could destroy the compressor. With these newer systems it takes a...
  25. Replies
    29
    Views
    1,243

    Actually they do not hold the system charge and...

    Actually they do not hold the system charge and also depending on the matched coil you may be adding significant amounts of gas. If the tx is restricted the condensor loads up with liquid and will...
Results 1 to 25 of 170
Page 1 of 7 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event