Search:

Type: Posts; User: oldhweller

Page 1 of 9 1 2 3 4

Search: Search took 0.01 seconds.

  1. BS!!!! Freedom and democracy are the most...

    BS!!!! Freedom and democracy are the most important.
  2. AMEN

    AMEN
  3. AMEN

    AMEN
  4. Replies
    1
    Views
    332

    I have a spare XL15b, if you need it. Thanks. ...

    I have a spare XL15b, if you need it. Thanks. Mike
  5. Replies
    5
    Views
    546

    Correctamundo

    Correctamundo
  6. Replies
    424
    Views
    13,527

    Seems like Kefah has disappeared from the thread,...

    Seems like Kefah has disappeared from the thread, leaving us to argue among ourselves.
  7. Replies
    65
    Views
    8,781

    Use your database backups and install on another...

    Use your database backups and install on another computer
  8. Thread: LON

    by oldhweller
    Replies
    12
    Views
    1,105

    Do either of these devices have active biasing...

    Do either of these devices have active biasing resistors? That is, pull-up and pull-down resistors to the the rail voltages? Add a small 12v DC power supply with 10k ohm resistors to the + and -...
  9. Replies
    7
    Views
    1,589

    Because we have a service contract with HW for...

    Because we have a service contract with HW for just this thing, HW installs the service packs. We both work together to make sure no problems arise. We have XL50s,Xl500s,XL800s,XL10(of various...
  10. Replies
    7
    Views
    1,589

    We have access to our HW techs and they have...

    We have access to our HW techs and they have TAC(Techanical Assistant Center support). Very seldom do we have to go past them. I used to work in TAC on this product, and the HW techs have known me...
  11. Replies
    7
    Views
    1,589

    EBi support

    We are an EBi customer and support ourselves. Yes there are questions we have, but our service contract covers this. No equipment covered. Where are you located? Thanks. Mike
  12. Replies
    7
    Views
    1,141

    Honeywell

    Huge amounts of documents available. We just need to know what controller. If it is XL500-5000 series, do you have CARE? If not you're SOOL!!!:gah:
  13. Replies
    5
    Views
    1,041

    cascade

    Are you using the Modbus interface or is the system standalone? There are 2 options for cascade. Each has a different sequence. Check the literature. I have several of these setups and they work...
  14. Replies
    20
    Views
    4,771

    EBi/Symmetre

    You obviously don't have any idea what you're talking about. If you've never done any EBi systems, you should not say anything.

    :censored:
  15. Replies
    3
    Views
    593

    AMEN

    Having worked for them I agree.
  16. Replies
    1
    Views
    407

    Fujitsu mini-split

    I have a Fujitsu ductless mini-split with the wired controller. It comes shipped with the configuration to use the indoor unit sensor not the t-stat sensor. See EN-5 page of the compact cassette...
  17. Replies
    33
    Views
    4,950

    condensor motors

    Has any one experienced condensor fan motor failures on these 30rba units? We have a 250 and a 125 and have lost about 12 motors. Failure mode is always bearing failure which then causes rotor to...
  18. Replies
    14
    Views
    1,733

    ISE

    Are these equations really accurate in the real world?:putergreet:
  19. Replies
    3
    Views
    1,078

    Floating is best

    I have always floated ALL inputs. NEVER take to chassis or electrical ground.
    Thanks. Mike
  20. Replies
    1
    Views
    293

    LNS plugin for Veris 8920-3

    :putergreet:Does anyone have a LNS plug-in for the Veris 8920-3 Modbus to Lon integrator. I know Veris doesn't support it any more and I can't get it from their website. TIA Mike
  21. Replies
    11
    Views
    2,162

    Either will work well. Floating control takes 2...

    Either will work well. Floating control takes 2 DO's where modulating takes 1 AO. Float control motors only use energy when moving. Modulating uses energy all the time. Your choice, but remember...
  22. Replies
    3
    Views
    620

    Communicating???

    I don't believe that these are communicating t'stats.
  23. Replies
    31
    Views
    1,477

    Math

    2 gigabit = 256m bytes(128M+128M)::putergreet:
  24. Replies
    9
    Views
    2,359

    EBi

    As said before, use the help files. I put in my first EBi in 2000 without any schooling, but with 30 years experience of HW systems. EBi, as said, is so powerful that its mind-boggling. However,...
  25. Replies
    1
    Views
    1,104

    HMMMMMM

    And then the fight started.:censored:
Results 1 to 25 of 215
Page 1 of 9 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event