Search:

Type: Posts; User: mh heating

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    35
    Views
    6,231

    Its a Hyla vacuum. Water filtered. I had one

    Its a Hyla vacuum. Water filtered. I had one
  2. Replies
    10
    Views
    1,598

    I think All HVAC equipment should be banned from...

    I think All HVAC equipment should be banned from Internet Sales
  3. Replies
    14
    Views
    1,561

    Late reply. Why did you add another dryer when...

    Late reply.

    Why did you add another dryer when they already have one installed? Also about txv. It may be superior but Goodman and AHRI show no improvement over fixed.

    Just curious
  4. Replies
    9
    Views
    1,047

    Oregon isn't much better. Those same Cali...

    Oregon isn't much better. Those same Cali dictators are moving here and implementing those same rules for us( not yet, but wont be long)
  5. Replies
    11
    Views
    882

    Smaller systems do OK with newer MH homes. Once...

    Smaller systems do OK with newer MH homes. Once you hit 3.5, air comes out is like a tornado. There's a local company (been here for over 100 yrs) sells little old ladies in pre '80 mobile homes, 15...
  6. Replies
    11
    Views
    882

    Duct work is the biggest problem, next is the...

    Duct work is the biggest problem, next is the return air. Most newer MH homes, the AH is in the laundry room and most of the time they have 20x20 grills in the Laundry doors. New AH...
  7. Replies
    87
    Views
    7,616

    Caps are code for new installs here in Oregon...

    Caps are code for new installs here in Oregon since 2012. Inspectors are finally starting to enforce them.
  8. Replies
    37
    Views
    9,047

    mitsubishi Mr slim all the way

    mitsubishi Mr slim all the way
  9. Replies
    5
    Views
    655

    I have a nit. regulator that only goes to 30 lbs....

    I have a nit. regulator that only goes to 30 lbs. just dial it in for 2 lbs. works for me
  10. Replies
    2
    Views
    487

    Coleman Guys..Need help with coil

    Have a customer that had his OD unit stolen so I need to find out what size (rating) this Indoor coil is. Model number is

    3340A830

    mh
  11. Removing- 2x4 5 ft long Loading- Make the...

    Removing- 2x4 5 ft long

    Loading- Make the supplier store do it on new equip
    improper lifting with the assist of the dolley - change outs
  12. Replies
    1
    Views
    537

    Appoin owners, question for you

    Looking at the operating procedures, it doesn't say anything about purging the lines, of air, before recovering freon. Is there something im missing or just crack a connection?
  13. How much air do you for a 150,000 NG Furnace....Not

    Went to do a bid the other day. This is what I found on a 37 year furnace. Tri level home with main return in bottom bedroom behind the tv, behind tight louvered door, under stair well, through 1/3...
  14. Replies
    102
    Views
    19,497

    Had this one the other day. Worst one I've come...

    Had this one the other day. Worst one I've come across. Goodman Unit

    http://www.use.com/media/2012/0825/2739744/p_001.jpg?1
  15. Replies
    102
    Views
    19,497

    This happened in 2008 in my area. Couldnt find a...

    This happened in 2008 in my area. Couldnt find a cap anywhere.
  16. Replies
    19
    Views
    3,114

    Thats will they're high static systems. Can we...

    Thats will they're high static systems. Can we say Tornado type air flow, LOL Our average temp here in summer is about 98* and 1 to 3 weeks of 110+
  17. Replies
    15
    Views
    1,972

    Nordyne has 14.5

    Nordyne has 14.5
  18. Replies
    19
    Views
    3,114

    The home must be an older model due to only...

    The home must be an older model due to only having a 1 speed fan and the Insulation factor is small. 3 tons (a/c only) seems about right for the area you live in (Michigan) should only struggle on...
  19. Replies
    38
    Views
    8,114

    I just watch some Yellow Jacket videos and they...

    I just watch some Yellow Jacket videos and they use their crt when using their vacuum setup
  20. Replies
    7
    Views
    1,451

    Love It

    Love It
  21. Replies
    74
    Views
    11,324

    Then it has to be with the suppliers we are...

    Then it has to be with the suppliers we are using. Different models I guess. More than likely we'll be doing the mc coils soon enough

    mh
  22. Replies
    74
    Views
    11,324

    Thats weird. All my nordyne Ah has the txv...

    Thats weird. All my nordyne Ah has the txv already installed on the indoor coils. Even the old R-22 ones. THese are all Kelvinator units

    mh
  23. Replies
    74
    Views
    11,324

    The picture I posted is a variable speed AH and...

    The picture I posted is a variable speed AH and rated for a 16 seer system and its a standard tube/fin design with their special coating. It might be different from supplier to supplier.

    MH
  24. Replies
    15
    Views
    2,027

    I just almost had the same problem on a nordyne...

    I just almost had the same problem on a nordyne hp in cooling mode. But.mine would go into suction at compressor. HPS did not trip. indoor Txv went bad.

    mh
  25. Replies
    74
    Views
    11,324

    This is from the new b6 series from nordyne. Its...

    This is from the new b6 series from nordyne. Its not a mc but what the call there ant eater coil. Has special coating to block the corrosive.

    ...
  26. Replies
    54
    Views
    6,008

    AHRI shows the same seer rating for goodman thats...

    AHRI shows the same seer rating for goodman thats using a orfice or txv.
  27. Replies
    74
    Views
    11,324

    I just checked out the microchannel coils for...

    I just checked out the microchannel coils for Nordyne. What a nightmare. Im doing a new construction job right now and am planning on installing a nordyne system. Looking at they're "quick data...
  28. Replies
    5
    Views
    896

    They use different size of venting and the new...

    They use different size of venting and the new ones are located a little farther back
  29. Replies
    6
    Views
    1,875

    Filter return grills in ceiling. mh

    Filter return grills in ceiling.
    mh
  30. Replies
    6
    Views
    1,875

    If you look closer, the zip tie is just holding...

    If you look closer, the zip tie is just holding the black insulation over the sealed end of the line set. Havnt sweated the connection yet. Waiting for the follow up appointment to finish it out.
    ...
  31. Replies
    6
    Views
    1,875

    Kelvinator 92+

    Kelvinator (nordyne) 92+ 3 ton a/c. Be going back soon to connect lines and matching outdoor a/c, install grills and thermo. Electrical and gas not done yet as of these pics. I know some of you dont...
  32. Replies
    11
    Views
    1,920

    lol. ya, its called scrape metal mh

    lol. ya, its called scrape metal


    mh
  33. Replies
    11
    Views
    1,920

    That gave me a chuckle MH

    That gave me a chuckle

    MH
  34. Replies
    11
    Views
    1,920

    Didnt get it started. coil burst in a couple of...

    Didnt get it started. coil burst in a couple of area over the winter. I ended up giving a bid for repairs (very High infact, didnt want to do it) . Never Heard back from them until a month later...
  35. Replies
    11
    Views
    1,920

    Water Source for Heat

    Went to do a bid for local realistate company on foreclosed home. They wanted a estimate to fix it. Home owner loved to do DIY's projects.
    Walked around the house and found this. I actually started...
  36. Replies
    5
    Views
    1,657

    Still got to go back to the job. The final stage...

    Still got to go back to the job. The final stage will take care of all the little stuff. Electrical was done by an electrician. Air handlers are Variable speed. Frigidaire equipment not to bad. ...
  37. Replies
    5
    Views
    1,657

    Old farm House Turned Museum

    First install on Wall of Pride thread. Hope all goes well.

    Frigidaire Heat Pump systems:
    Upper floor Three Zones using Ultrazone equipment
    Main floor One: Two Zoned system
    Second:...
  38. Replies
    13
    Views
    4,109

    Its for air storage for his rear shocks. Guess...

    Its for air storage for his rear shocks. Guess he wanted to be different.
    MH
Results 1 to 38 of 247
Page 1 of 5 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards