  1. Replies
    28
    Views
    2,818

    Sorry but we can not advise you other than you...

    Sorry but we can not advise you other than you need a pro at this point. Many apologies. I am sorry it is going to get hot ,I also wish there was more we can do but rules is rules.
  2. Replies
    18
    Views
    1,670

    define universal is it like the turbo 200 caps a...

    define universal is it like the turbo 200 caps a multi mfd? the right cap is the right cap as long as he got the mfd and the voltage right you cant do a 370 whert a 440 went if it is universal that...
  3. Replies
    28
    Views
    2,818

    Really? This smells like DIY to me. A normal...

    Really?
    This smells like DIY to me. A normal homeowner does not need to worry how the pressures look. The only thing they need to worry with is if it blows cool and is my light bill OK? Just sayin....
  4. Replies
    44
    Views
    5,002

    The new guy sounds like he has his ducks in a...

    The new guy sounds like he has his ducks in a row. The loss probably did occur when the other guy changed the valve cores. Even with the tool ,it can get ugly for the untrained. I agree that 24 hours...
  5. Replies
    15
    Views
    3,100

    I am actually changing my mind. I am not having...

    I am actually changing my mind. I am not having this argument. I have got almost three grand in this piece of junk single wide I live in just for the guy that gave me the place and that also rents me...
  6. Replies
    15
    Views
    3,100

    You say WOW like I said something wrong .I can...

    You say WOW like I said something wrong .I can see the vinyl flooring in the second picture. It does not look like it is in the duct mainly because ducts don't have vinyl floor on top of them. It...
  7. Replies
    15
    Views
    3,100

    are you sure that is the duct I have installed in...

    are you sure that is the duct I have installed in a bunch of trailers and have never seen that . It looks like the duct work behind the line set to me. Actually to put the line through the duct is...
  8. Replies
    30
    Views
    3,305

    I have seen compressors die after cleaning coils...

    I have seen compressors die after cleaning coils like that.
  9. Replies
    16
    Views
    1,752

    That was my point , I love learning. That is why...

    That was my point , I love learning. That is why I asked all the questions.
  10. I think it is a good refrigerant. I think that...

    I think it is a good refrigerant. I think that Copeland will get on board with it. As far as the ten degree guide I did not read that in the retro fit guidelines issued by DuPont. It has all the...
  11. Replies
    16
    Views
    1,752

    I am not real sure what having my own business...

    I am not real sure what having my own business has to do with it. I would go with a higher suction pressure as a symptom. Or maybe even a rising suction pressure. I just wanted to know because I have...
  12. Replies
    16
    Views
    1,752

    Hey this has me really curious because I love to...

    Hey this has me really curious because I love to learn different trouble shooting methods. Where are these temps being taken at ? Also if this guy at GooooodMAN says 4 degrees , then what is the...
  13. yes sir you are correct. If they are only six...

    yes sir you are correct. If they are only six years old then they are more than likely OK . Good luck. New coil and condenser with a lineset purge and you will be living in the great world of r410a...
  14. Replies
    16
    Views
    5,402

    Does it come in blue ?

    Does it come in blue ?
  15. The gas furnaces are the Air handlers as they do...

    The gas furnaces are the Air handlers as they do have the blower fan inside them. You have two case coils to replace. As long as the heat exchangers are not cracked you can just replace the indoor...
  16. Replies
    44
    Views
    5,002

    Is there any option of getting a different...

    Is there any option of getting a different contractor ta all? If so a second opinion would be grand.
  17. Replies
    44
    Views
    5,002

    yes the gas just dissipated When I put my...

    yes the gas just dissipated
    When I put my detector in a cabinet and it goes off I go ahead and call for indoor coil replacement. If it went off in the cabinet you have a leaky indoor coil , bottom...
  18. Replies
    44
    Views
    5,002

    ALL evaporator (indoor) a-coils ,evaps period are...

    ALL evaporator (indoor) a-coils ,evaps period are more prone to leaks than the outdoor section. The copper is thinner for one to allow for better heat exchange. If it is a heat pump,then this also...
  19. Replies
    44
    Views
    5,002

    No,the valves generally don't fail just after a...

    No,the valves generally don't fail just after a few times of hooking gauges up a few times. The valve probably got burnt just like you said when they repaired the 90 degree bend. It happens all the...
  20. Replies
    44
    Views
    5,002

    Hope that helps. On a side note the prticular...

    Hope that helps. On a side note the prticular technician working on the unit may not be able to spell Air conditioner but the guy that started the company the bone head is representing may actually...
  21. Replies
    44
    Views
    5,002

    Actually this is not a problem only specific to...

    Actually this is not a problem only specific to Trane or American Standard. The service valve is the part of the outdoor unit where we hook our gauges to the unit,all units have them. The service...
  22. Replies
    44
    Views
    5,002

    There are not any o ring seals in the system...

    There are not any o ring seals in the system normally. I see now about the labor part. The dye would still be a good idea since this thing has been such a problem. I had one recently that gave me a...
  23. Replies
    44
    Views
    5,002

    He didn't even use his leak detector around the...

    He didn't even use his leak detector around the air handler, only outside, and only after I insisted. Then he acted like he was just humoring me. I'm thinking that we need the dye to catch an...
  24. Replies
    44
    Views
    5,002

    They can be changed quickley with the tool for...

    They can be changed quickley with the tool for removing valve cores. There should not be all this talk of tearing into the system,you find the leak,you fix it. If that entails removing one of coils...
  25. Replies
    44
    Views
    5,002

    If the valve was definitely the leak then it for...

    If the valve was definitely the leak then it for sure was over heated on installation. I noticed you said he did not change the schrader cores when he did the service. The refrigerant has been...