  1. give me a call. I sent you a private msg.

    give me a call. I sent you a private msg.
  2. The furnace won't have anything to do with the...

    The furnace won't have anything to do with the fault.Reset the system and watch it. If the fault comes up again call a tech.
  3. Replies
    75
    Views
    10,623

    I agree. Get a new tech!

    I agree. Get a new tech!
  4. look at a P/T chart

    look at a P/T chart
  5. Replies
    12
    Views
    1,426

    Carrier for the most part is the industry leader...

    Carrier for the most part is the industry leader in controls and new technology. For instance 410-A systems.The other brands are working on controls like the infinity but are still aways away. I...
  6. CARRIER,the infinity zone system will make...

    CARRIER,the infinity zone system will make everything work great.I have not seen another brand work as well as the Carrier control system.(infinity)The Bryant equipment is the same if you don't like...
  7. Replies
    8
    Views
    641

    Yes we can service that area. Did he replace the...

    Yes we can service that area. Did he replace the coil and outdoor temp sensors as well, or just the board.If you would like me to come out for a service send me a private msg with your name and phone...
  8. Replies
    18
    Views
    1,201

    My bad I didn't see that part of his post. I...

    My bad I didn't see that part of his post. I agree more R/A is needed
  9. Replies
    18
    Views
    1,201

    It is a harmonic noise from the grill itself. All...

    It is a harmonic noise from the grill itself. All you have to do is turn the return grill or tweak the veins in the grill.
  10. Replies
    20
    Views
    2,541

    They may have put the 005 unit in to match...

    They may have put the 005 unit in to match ductwork, but the max size heat pump or A/C unit can ONLY be 48,000 btu or 4 ton for that size I/D unit!!!
  11. Replies
    8
    Views
    641

    The O/D temp must be below 50. The evolution...

    The O/D temp must be below 50. The evolution control just tells the O/D unit how often to look at the sensors. The O/D unit does everything else.
  12. Replies
    6
    Views
    926

    I have the infinity in my home and it works great...

    I have the infinity in my home and it works great the only problem will be the cost once per year to replace the filter. But like I ask my customers, how important is the air you and your children...
  13. Replies
    20
    Views
    2,541

    Jerry, I agree with Ryan a Carrier FV4BNF005 is...

    Jerry, I agree with Ryan a Carrier FV4BNF005 is the wrong air handler.That unit is only big enough for a 4 ton unit max.You need an FV4BNB006 unit. But I would rather see the Infinity I/D unit as...
  14. sounds like you should call a contractor to see...

    sounds like you should call a contractor to see if the unit is operating ok and set the defrost to a different time maybe?
  15. You must use a bypass damper if not using an...

    You must use a bypass damper if not using an infinity zone system. The honeywell system does not modulate dampers they are either full open or closed.
  16. Replies
    2
    Views
    299

    Did the contractor put the new inducer parts in...

    Did the contractor put the new inducer parts in yet?
  17. Replies
    161
    Views
    59,748

    Just try to make sure the contractor knows what...

    Just try to make sure the contractor knows what they are doing. That can make or break a system. I do know from exp Goodman stands behind there products.
  18. Replies
    161
    Views
    59,748

    What kind of training do you have in mind? I...

    What kind of training do you have in mind?
    I don't see anywhere that I'm bashing anything,just stating the facts.
  19. Replies
    161
    Views
    59,748

    I wish you good luck with the Goodman. I just...

    I wish you good luck with the Goodman. I just hope it does ok in the extreme heat or cool.We are installing the last goodman product that we bid out this weekend and I hope it starts up ok.I have my...
  20. Replies
    161
    Views
    59,748

    My company tried to sell goodman for awhile.(are...

    My company tried to sell goodman for awhile.(are main line is Carrier)We put in 6 or so complete heat pump systems and every one of them had a problem of some sort, one even had a hole in the I/D...
  21. I am from WA so we are in the heating season. If...

    I am from WA so we are in the heating season. If you are in the heating mode the O/D fan being slow would NOT have anything to do with the problem.
  22. Replies
    20
    Views
    2,541

    Sounds like the contractor sort of screwed you.I...

    Sounds like the contractor sort of screwed you.I would demand the infinity I/D unit as well as the infinity zone control.(you may have to pay extra for that)The salesman should have known that you...
  23. Sounds like there is a problem with txv(if there...

    Sounds like there is a problem with txv(if there is one in the system)or the I/D piston. But it could be overcharged or there is a problem with air flow since you say the low side is ok.We need to...
  24. The lockout temp set at 35 and below is o.k. But...

    The lockout temp set at 35 and below is o.k. But you should set the airflow to maximum. We want all the air flow we can give for the infinity H/P to work properly.Remember more humidity in the house ...
  25. Where is around here. I would like to open a...

    Where is around here. I would like to open a company there. Like I said I hate that the builders use the equip for temp heat.