    not a split

    I have done one package replacement, and one package new install
    Have not done a split system with a vertical air handler
  2. Replies
    12
    Views
    1,217

    Purchased Haier R410A Heat Pump

    HR48D1VAE Heat Pump &
    Air Handler HB4800VD1M22
    Purchased them at a surplus auction
    They are new and under warranty
    Before I go an install them, first
    1. are they matched
    2. Is there prefabbed...
  3. Replies
    15
    Views
    1,608

    Another exciting find

    It would seem that any time an external device sets a value
    to a Network Analog Parameter, or any tag (example M045)
    there is a part of the tag M045 in run time thats called
    Priority Array. The...
  4. Replies
    15
    Views
    1,608

    interesting

    I will need to look into that tomorrow
    Will post my finding here
    Thanks
  5. Replies
    15
    Views
    1,608

    Problem using the opc server write

    Have not rulled out using the hardware, but here is something we have discovered

    1. We are able to access the software related EIKON tags
    2. We are able to read from them

    3. Now for the bad...
  6. Replies
    15
    Views
    1,608

    L-INX Automation Server Model 200 or 201.

    I looked at that. It is another piece of hardware.
    We have kepware opc driver working but all it is seeing is
    the native firmware tags, we can not seem to connect to the
    logic tags, nor discover...
  7. Replies
    15
    Views
    1,608

    what device

    How does that work
  8. Replies
    15
    Views
    1,608

    Wonderware OPC to ALC

    Have a customer who wants Wonderware as a operator station setting on top of ALC. Anyone recommend an OPC driver for that.
    Using a LGR250 and the router.
  9. Replies
    10
    Views
    739

    email bounced

    So we could meet up somewhere as the forum in concerned about
    emails on the posting.
    I live in SoCal, if I remember correctly you are somewhere
    close to that.
    Also maybe I should take this to the...
  10. Replies
    10
    Views
    739

    rules

    No one put an email in the message
    No one is going to spam anyone
    It is about a Real Job offer in Southern California
  11. Replies
    10
    Views
    739

    email bounced

    Please do not post email or IP addresses!
  12. Replies
    1
    Views
    668

    Wonderware > ME812U-LGR Topic

    Anyone have a sample of setting up the Kepware Bacnet OPC
    driver in Wonderware to pull data from a ME812U-LGR module
    over the Bacnet/IP network.
    Maybe even a project or screen shot of the topic...
  13. Replies
    10
    Views
    739

    ALC to Delta Cross Reference

    ALC to Delta cross reference

    --------------------------------------------------------------------------------

    ALC ME812u-LGR Delta > ?
    ALC MEX816U Delta > ?
    ALC ZN341V+ Delta > ?

    so...
  14. Replies
    0
    Views
    294

    ALC to Delta cross reference

    wrong place
    sorry
  15. Replies
    0
    Views
    388

    ACH550 with FENA-01 Ethernet

    Modbus TCP/IP over Ethernet using the FANA-01 interface for ACH550
    drive. Anyone ever use ALC to talk to the ACH550 this way.

    Thanks
  16. Thread: ALC sal file

    by asterof
    Replies
    0
    Views
    291

    ALC sal file

    as usual, ALC sent me a Standard Application Library in the form of
    a sal file, and of course no instructions on how to import it
    Anyone ever had to do that.
  17. Replies
    0
    Views
    258

    Old or maybe not so old TAC

    anyone recognize these numbers

    7716 PCU
    7760 UCI
    7792 MRI
    7798 MCI
    7780 LCU

    if you do could you post what they are
    I know the PCU is a Processor Control Unit
  18. Replies
    1
    Views
    1,340

    CCOntrols BASRT-B Router

    Any one ever used sitebuilder to set up a Bacnet/IP
    from the comp to a BASRT-B Bacnet/IP to MSTP router
    BQT can see the mstp device fine, but modtest inside sitebuilder
    does not see even the...
  19. Replies
    32
    Views
    2,755

    you miss understood

    I bought those to self train
    not install for the customer
    The customer purchased all the ALC that was needed
    If it upsets you, maybe offer more help and knowledge next time
    I will be posting all...
  20. Replies
    32
    Views
    2,755

    How it is going

    System is up and running
    I purchased modules off ebay, set up the MSTP port and built a small
    system consisting of two ZN341V+, one ME812u-LGR and one MEX816u
    all on a rs232-485 converter.
    I used...
  21. Replies
    32
    Views
    2,755

    It is a shame

    Seems everyone here is still beating around the bush, maybe because of the
    protection of vendor issues that ALC seems to like to control.
    Only a few have really offered to help me with some of the...
  22. Thread: CO2

    by asterof
    Replies
    11
    Views
    1,356

    CO2

    To monitor CO2 levels in an office building, where would one place the sensor
    In the Office space or in the Supply Air.
    Thanks
  23. module

    I know u were asking 500, it is for personal test rig, what would
    u let it go for.
  24. You still have the M8102

    You still have the M8102
  25. Replies
    32
    Views
    2,755

    Appreciate the offer

    but it is more for cad layout than actual wiring
    needed to do a cad drawing for electrical contractor