10-14-2009, 03:40 PM
Thread: Duct Camera
by ferd42- Replies
- 7
- Views
- 937
Good for Prince William County; that complies...
Good for Prince William County; that complies with the ADC Standards. And what's with the screws? Do you think that stuff's going to fly away?
I've been reworking my flex in Sussex County, DE; no... -
10-13-2009, 08:12 AM
Thread: Duct Camera
by ferd42- Replies
- 7
- Views
- 937
Another Question
I'll be looking for restrictions in flex ducts. I'm planning on going through branch ducts from the air outlets, and it'd be nice to continue into the main ducts for a look around. Will it fit around...
-
10-13-2009, 08:07 AM
Thread: Duct Camera
by ferd42- Replies
- 7
- Views
- 937
Thanks! Looks like the camera base is on wheels....
Thanks! Looks like the camera base is on wheels. How does it do going through 5" to 8" flex duct? Do you have any problems getting around the screws securing round ducts? Again, thanks.
-
10-11-2009, 03:34 PM
Thread: New system installed today
by ferd42- Replies
- 28
- Views
- 1,489
Good for (Contractor's) Business
Why in the world would you increase the capacity when the old, smaller system performed so well? I'd have gone over the duct system, improved sealing and insulation, and put in a smaller system than...
-
10-11-2009, 03:19 PM
Thread: R-410A / Heat Load calc.
by ferd42- Replies
- 14
- Views
- 1,043
Good Answer
REALLY!
-
10-11-2009, 03:16 PM
Thread: Calculation
by ferd42- Replies
- 12
- Views
- 367
KDC: I may be able to help. Please send a...
KDC:
I may be able to help. Please send a follow-up:
1. Is this a summer- winter hookup, wherein the boiler provides domestic hot water?
2. If so, do you have (or can you obtain) 12 months' gas... -
10-11-2009, 03:07 PM
Thread: Duct Camera
by ferd42- Replies
- 7
- Views
- 937
Duct Camera
I've decided that it would be good to have a duct camera (AKA "Push Camera"); would appreciate any comments on recommended features, preferred brands, etc. Many thanks!
-
07-06-2009, 04:37 PM
Thread: Poor cooling on 2nd floor
by ferd42- Replies
- 27
- Views
- 2,384
Duct Analysis
Did you look at the "Contact Us" page?
-
07-06-2009, 04:31 PM
Thread: Poor cooling on 2nd floor
by ferd42- Replies
- 27
- Views
- 2,384
Flexible Duct Bends
Centerline radius must be equal to (or preferably greater than) duct diameter. If the bend is down, the horizontal flex must be supported adjacent to the bend to prevent sagging over time.
If... -
07-06-2009, 01:50 AM
Thread: Poor cooling on 2nd floor
by ferd42- Replies
- 27
- Views
- 2,384
Well, if you're looking for an engineer, you...
Well, if you're looking for an engineer, you might surf askweldin.
-
07-03-2009, 05:37 PM
Thread: GE THQC Circuit Breaker Failures
by ferd42- Replies
- 3
- Views
- 466
That would be two, but only had trouble with the...
That would be two, but only had trouble with the first stage (also powers 2.6A blower).
-
07-03-2009, 11:00 AM
Thread: GE THQC Circuit Breaker Failures
by ferd42- Replies
- 3
- Views
- 466
GE THQC Circuit Breaker Failures
Has anyone had trouble with breakers overheating and becoming open internally? The particular breakers we've seen were 60/2 240V in a 20KW strip heater. Breakers were manufactured during the fifth...
-
08-22-2008, 03:50 PM
Thread: Quotes without any measuring
by ferd42- Replies
- 17
- Views
- 1,475
Overkill
WOW!! What a structure, you could probably heat it with a few candles. Seriously though, 40MBH is way more than you'll need for a quick warmup; there's nothing to be gained with a two stage.
... -
08-21-2008, 06:11 PM
Thread: Quotes without any measuring
by ferd42- Replies
- 17
- Views
- 1,475
What's With Two Stage/Modulating?
Why go to the expense?
Here are three options to consider (cheapest to most expensive):
1. Heat pump with resistance backup, wear sweaters and live with the wildly fluctuating temperatures and... -
08-20-2008, 06:30 PM
Thread: heat pump for drafty house
by ferd42- Replies
- 33
- Views
- 1,425
Atlanta Design
Manual J: 23 winter, 91 summer. This is a very good heat pump application: Very few hours below balance point; size it for the Manual J cooling load. Needless to say, you need to do something to...
-
08-20-2008, 06:21 PM
Thread: using square foot per ton basis
by ferd42- Replies
- 51
- Views
- 16,437
1993 Model Energy Code
I live in a "Retard Jurisdiction" (no names, to protect me from whatever), still under 93 MEC. It's been illegal to use "Rules of Thumb" (SF?Ton) for at least 15 years, yet there are "Dinosaurs"...
-
08-20-2008, 06:59 AM
Thread: Foundation Plenum
by ferd42- Replies
- 7
- Views
- 723
Crawl Space
The object is to construct an airtight above ground crawl space and operate it at +0.15" or +0.20" WC in the real world, and to do it in such a way that it won't hasten the occupants' demise in a...
-
08-19-2008, 08:42 AM
Thread: Quotes without any measuring
by ferd42- Replies
- 17
- Views
- 1,475
Heat Loss Calc
Just learned something: Manual J Table 1B supercedes Table 1A; that means your design is 8 degrees (Table 1B), not 13 degrees (Table 1A, identical to the ASHRAE 99% value I quoted). I did a quick...
-
08-18-2008, 03:31 PM
Thread: Moving Air.
by ferd42- Replies
- 4
- Views
- 399
Transfer Fan
You might try a transfer fan in the wall; Broan #511 is one type. I would think this is a Code violation: There's no H/C in the bedroom; I know it's a small place, but still...
-
08-18-2008, 09:48 AM
Thread: Foundation Plenum
by ferd42- Replies
- 7
- Views
- 723
ACCA Manual D
Some good "How To" stuff on pages 1-14 & 15, para: 1-10. Gives you the plenum pressure needed, etc.
-
08-18-2008, 09:43 AM
Thread: Quotes without any measuring
by ferd42- Replies
- 17
- Views
- 1,475
Heat Pump
You have very little heating required, even at 13 degrees; the smallest gas furnace (37MBH out) would be overkill. Don't use oil. Be prepared for widely fluctuating discharge temperatures when it's...
-
08-18-2008, 09:39 AM
Thread: Foundation Plenum
by ferd42- Replies
- 7
- Views
- 723
NEC
300.22(B) applies: All wiring methods are to be plenum rated; that means MC cable, not Romex - you may not be able to use regular thermostat cable, phone cable, etc. Check with your AHJ.
-
08-18-2008, 09:35 AM
Thread: Foundation Plenum
by ferd42- Replies
- 7
- Views
- 723
Nfpa 90b
There are a LOT of restrictions on how this may be done. Basically, they're concerned with the spread of fire and products of combustion (OK, say "DUH" - that's what duct Codes are all about). The...
-
08-18-2008, 08:23 AM
Thread: Quotes without any measuring
by ferd42- Replies
- 17
- Views
- 1,475
No Need For Two Stage
13 degree design, with heated space above and below (seem to remember something about heat rising). If the first stage is more than you need (as it is here), why go to the expense of a two stage?
-
08-17-2008, 08:50 PM
Thread: New system too small?
by ferd42- Replies
- 15
- Views
- 1,181
$150
Been There:
Thanks for clarifying my statement, you're right on.
Results 1 to 25 of 27