Search:

Type: Posts; User: dapper

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    5
    Views
    965

    Considering that most members on this thread are...

    Considering that most members on this thread are 'Professional' this topic should be dealt with in the Pro Forum.
    I know the factory defaults but will not spill them out here in the public forum.
  2. Replies
    1
    Views
    77

    iLONVision and Contribute CS3

    I have an older laptop with iLONVision ver. 4.02.029 and iLONSMartServer ver. 4.02.055 installed.

    When I open Contribute CS3 the iLON button does not show in the toolbar. I searched some old...
  3. Replies
    2
    Views
    887

    I am having this problem now. Anyone else have...

    I am having this problem now. Anyone else have this issue and find a different solution?
    I haven't tried an alternate FTP yet but will try it tomorrow
  4. Replies
    4
    Views
    270

    The only exception that I have seen is if there...

    The only exception that I have seen is if there is no power to the unit or comm is lost. The message will say Normal {down}, or whatever state it was in before the comm was lost, but it will be...
  5. Replies
    4
    Views
    270

    I use a lot of Trane stuff and never saw this...

    I use a lot of Trane stuff and never saw this problem before. If the nvoStatus_inAlarm is active the current nvoAlarmMessage should display. Do you get 'Normal' in the alarm message? I have had...
  6. Replies
    8
    Views
    696

    381, I've seen some of Lonboys pages. Maybe only...

    381, I've seen some of Lonboys pages. Maybe only a notch or two below this. :yes:

    He is a hell of an instructor though.
  7. Replies
    22
    Views
    1,371

    Work like this makes us all look bad. I always...

    Work like this makes us all look bad. I always tried to impress on my guys that most customers have no clue how a control system works but if the work is done neat and clean they will be very...
  8. Replies
    8
    Views
    696

    Ditto on LonMaker, but the guy has to learn how...

    Ditto on LonMaker, but the guy has to learn how to add pages. I've never seen anything like that all on one page.
  9. Replies
    3
    Views
    199

    Thanks Nick!!

    Thanks Nick!!
  10. Replies
    3
    Views
    199

    JCI Site Builders User's Guide

    Anyone have a copy of this that they can share?
  11. Replies
    6
    Views
    458

    Thanks guys. I have looked at the Siemens...

    Thanks guys. I have looked at the Siemens RAA10CW but it seems that the concealed setpoint is only in celsius. Im not sure that will fly on this job.
    The Accustat is a good suggestion but I think...
  12. Replies
    6
    Views
    458

    Concealed setpoint thermostat

    I have a spec for hot water radiation thermostats to be low voltage, "bi-metal mercury type", with a concealed setpoint. It must also be mounted on a wall box (2 x 4).

    I realize that the mercury...
  13. Replies
    2
    Views
    197

    Mitsubishi M-NET

    Mitsubishi' spec calls for the M-NET cable to be 'Shielded Cable Type CVVS or CPEVS'. These seem to be Asian standards.
    Is this just standard 16 ga. shielded wire or is there something special...
  14. Thread: KEP MINItrol

    by dapper
    Replies
    4
    Views
    171

    joey, thanks for the link. That is one of the...

    joey, thanks for the link. That is one of the documents that I have already but I think it may be only for RS232 interface and not the MODBUS interface. In each case they use a DB9 connector with a...
  15. Thread: KEP MINItrol

    by dapper
    Replies
    4
    Views
    171

    joey, I have tried HyperTerminal and Putty. No, I...

    joey, I have tried HyperTerminal and Putty. No, I have not used 2 stop bits. The documentation that I have says 1 stop bit.
    Do you have the manual in pdf? Can you send it to me?
  16. Thread: KEP MINItrol

    by dapper
    Replies
    4
    Views
    171

    KEP MINItrol

    Anyone have any experience with a KEP MINItrol Ratemeter & Totalizer? I have one with a MODBUS RTU interface that I am unable to communicate with. I sent it back to the factory
    once and they said...
  17. Replies
    17
    Views
    1,119

    Ditto the KMC FlexStat

    Ditto the KMC FlexStat
  18. Replies
    0
    Views
    141

    Istec water meter and display

    Anyone have experience with an Istec series 1800 water meter with a Model 9305 display with Modbus interface?
    I'm having some issues configuring the interface as it defaults to 300 baud. There...
  19. Thread: 3D Floorplans

    by dapper
    Replies
    13
    Views
    1,083

    Nice work mechdorn!

    Nice work mechdorn!
  20. Thread: best lap top

    by dapper
    Replies
    30
    Views
    1,224

    In my opinion memory and speed are not that...

    In my opinion memory and speed are not that important with most control systems. Most controls system interfaces are very slow to start with. if you plan on creating your own 3d floor plans etc. on...
  21. Replies
    32
    Views
    1,487

    controldude might be on to something with the...

    controldude might be on to something with the theory of the wall mass. Try to get your hands on an infrared thermometer and check the wall temperature when your cooling system is running wild like...
  22. Thread: BabelBuster...

    by dapper
    Replies
    1
    Views
    287

    BabelBuster...

    Any experiences, good or bad, installing a BabelBuster 485 Lonworks to Modbus RTU on a Tridium Lon network?
  23. Replies
    21
    Views
    563

    I hope I didn't miss something here but there are...

    I hope I didn't miss something here but there are 2 different free programmable plugins. There is the old version and the GFX version. I don't believe the GFX version will work with the EC8A even...
  24. Thread: WSHP DP switch

    by dapper
    Replies
    14
    Views
    564

    Matt, I've installed thousands of water source...

    Matt, I've installed thousands of water source heat pumps over the years and never saw a spec. or a manufacturers recommendation to install diff. pressure switches across the condenser coils. The...
  25. Thread: WSHP DP switch

    by dapper
    Replies
    14
    Views
    564

    Another engineer that has no clue what they their...

    Another engineer that has no clue what they their spec says
  26. Thread: BBMD vs VPN

    by dapper
    Replies
    25
    Views
    2,287

    Landmine, not for nothing but your username and...

    Landmine, not for nothing but your username and avatar make me a little 'queasy'. I mean no disrespect if this is something that you have gone through but if this is meant to be funny, I'm having a...
  27. Replies
    3
    Views
    369

    Ok, just searched my old posts. It was Digo that...

    Ok, just searched my old posts. It was Digo that straightened me out. If you are doing this remotely you have to open the Fox port on your network. The two ports that need to be open on your...
  28. Replies
    3
    Views
    369

    If it kicks you right back to the login screen...

    If it kicks you right back to the login screen then I think you are missing a module on the Jace, or you have a license issue. Is the webui licensed? I've had this problem before but don't remember...
  29. Replies
    0
    Views
    134

    Trane WSHP with wireless t'stats

    Have a job with Trane WSHPs with Trane wireless t'stats. I've noticed lately that you cannot turn off the fan or turn the unit off through the t'stat. Set the mode to OFF and the unit continues to...
  30. Replies
    26
    Views
    2,188

    Thanks guys, I'll look into the Max Line driver. ...

    Thanks guys, I'll look into the Max Line driver. I can work with the N2 devices. I don't get a lot of exposure but I took the DX class many years and still remember the basics. I've already...
  31. Replies
    26
    Views
    2,188

    Dredging up this old thread with some notable old...

    Dredging up this old thread with some notable old friends.
    I recently got involved with a building that has 3 N30s, 5 dx-9100s and 20 or so VMAs. The previous contractor 'took' the M-3 front-end...
  32. Thread: N30 User Manual

    by dapper
    Replies
    6
    Views
    248

    Got Project Builder, thanks.

    Got Project Builder, thanks.
  33. Thread: N30 User Manual

    by dapper
    Replies
    6
    Views
    248

    Have that one already, thanks.

    Have that one already, thanks.
  34. Thread: N30 User Manual

    by dapper
    Replies
    6
    Views
    248

    N30 User Manual

    Anyone have a current copy of the N30 User Manual. I have a 2001 version but would like something more current. There seems to be a problem with the online source.

    Thanks in advance
  35. Replies
    25
    Views
    2,238

    ruchc30, I went ahead and reloaded the 3 patch...

    ruchc30, I went ahead and reloaded the 3 patch files just to be sure there wasn't an issue there. I overwrote the wbapplet.jar. The baja.jar and fox.jar were the same. I cleared all of the caches...
  36. Replies
    25
    Views
    2,238

    mechmike, I tried that after posting the last...

    mechmike, I tried that after posting the last post. I logged on just fine with IE and Firefox after that the first time, but subsequent times there was no data. 'Config > Drivers' tree will not open....
  37. Replies
    25
    Views
    2,238

    Ok, I've spent some time and logged in using the...

    Ok, I've spent some time and logged in using the restricted User credentials with Workbench and have no issue. I can simultaneously log in with another PC with either Firefox or IE and I get no...
  38. Replies
    2
    Views
    396

    Training.... joey, klrogers

    Thought I would take the training discussion here instead of hijacking that post.
    Yea.. the training in Richmond really whizzed by me because that was my first exposure to Tridium but it was a...
  39. Replies
    16
    Views
    1,124

    incontrol, sorry to hear that you had some bad...

    incontrol, sorry to hear that you had some bad experiences. Most of mine have been pretty positive. I took the Tridium training in Richmond and thought it was very worth while. The LON training I...
  40. Replies
    25
    Views
    2,238

    Just another note. We deleted the user and added...

    Just another note. We deleted the user and added new users with permission, always the same result. Hit or miss when data is loaded in px pages.
  41. Replies
    25
    Views
    2,238

    After a lot more investigation this is what I've...

    After a lot more investigation this is what I've found. The problem seems to be in the 'Category Service' or the permissions software. If I change the problem user to 'super user' there is no...
  42. Replies
    0
    Views
    213

    Jace web page data problem

    Deleted
  43. Tridium was the original brand / company. They...

    Tridium was the original brand / company. They branded Vykons, the open channel and Honeywell Webs, the branch channel for Honeywell. Honeywell bought the Tridium company but still keeps thier two...
  44. Replies
    2
    Views
    294

    Thanks Kevin. As it turned out, thier e-mail...

    Thanks Kevin. As it turned out, thier e-mail server was not accepting e-mails for the Jace's IP address. I was told otherwise earlier in the week but the IT guy took care of it for me today.
  45. Replies
    2
    Views
    294

    AX E-mail problem

    New e-mail setup on Jace 2. Outgoing e-mail enters the queue but is then discarded. The message in 'Last Discard Cause' is
    "...530 5.7.1 Client was not authenticated"
    It seems to poll ok until...
  46. Replies
    2
    Views
    327

    Trane ZN510 "resetting" on Ax system

    I've recently seen a post referring to something similar but I am unable to find it now. I ignored it at the time because I never saw that problem before. I should have paid more attention.
    The...
  47. Thread: Lon program id

    by dapper
    Replies
    2
    Views
    386

    The program Id in a controller can be changed by...

    The program Id in a controller can be changed by upgrading the .APB (or Application) software in the controller if it's a LonMark device. In the fx20 you can change the program Id by changing the...
  48. Returns closed

    Returns closed
  49. Replies
    9
    Views
    866

    Can't speak for the BACnet line but the LONworks...

    Can't speak for the BACnet line but the LONworks stuff works just fine.
  50. No... as outdoor air temps dropped below 20f they...

    No... as outdoor air temps dropped below 20f they were driving outdoor air dampers to 100% open. Reheats were unable to keep up, space temps not maintaining temps. Boilers not keeping up, coils...