Search Results - HVAC-Talk: Heating, Air & Refrigeration Discussion

Search:

Type: Posts; User: leakcheck

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    8
    Views
    490

    I would also be interested in your guide. My...

    I would also be interested in your guide. My email is in my about me page if you click on my name to view my profile.
  2. Replies
    4
    Views
    183

    That's what I did for the first to AHUs they are...

    That's what I did for the first to AHUs they are back to back to an OA plenum 2 climate changers from the late 90s. But its tough to figure out what sensors are for what AHU being they only use 1...
  3. Replies
    18
    Views
    631

    I will send you an Email titled UPCM GET. I know...

    I will send you an Email titled UPCM GET. I know they dont like it much if you post emails in the forums. Thanks again Calder!
  4. Replies
    18
    Views
    631

    Actually ended up getting it and a programming...

    Actually ended up getting it and a programming guide from a guy at work thanks for the offer!
  5. Replies
    18
    Views
    631

    Thank you soooo much. I havnt received it if you...

    Thank you soooo much. I havnt received it if you sent it. If you havnt gotten time no rush just letting you know it didnt go through if you did.
  6. Replies
    18
    Views
    631

    Is there a possibility I could get a copy of this...

    Is there a possibility I could get a copy of this program also please. Need a way to get a points list.
  7. Replies
    4
    Views
    183

    It has tracer summit. not sure on the version...

    It has tracer summit. not sure on the version though its from the late 90s.
  8. Replies
    4
    Views
    183

    Trane UPCM to PCG

    Hi,
    I am trying to change out several AHUs using UPCMs to run AHUS they have 2 AHUS per UPCM and have probably a dozen inputs and 8 or 10 outputs total between the 2 AHUS.
    If I can look on Summit ...
  9. Replies
    3
    Views
    348

    You will need to put the prn files on the jace...

    You will need to put the prn files on the jace and then use the discovery and find the prn file or dmo if its a dx9100.
    If you do not have the prn file then you will need to get them from the...
  10. Replies
    3
    Views
    288

    Yea priority slot 8 is reserved for the override...

    Yea priority slot 8 is reserved for the override function and Is not writable at least on a vykon asside from the override.
  11. Replies
    3
    Views
    348

    vykon Jace 700 N2 issue

    I have a Vykon Jace 700 with a N2 trunk (Ibms-N2 driver) and some of the VMA' s on the trunk share a Zone sensor. When I link mark the ZN-T they work fine but the randomly get a exceptionCode#0 in...
  12. Replies
    13
    Views
    388

    I ended up using a oneshot tied to release all to...

    I ended up using a oneshot tied to release all to the false command of a numeric switch.
  13. Replies
    13
    Views
    388

    Thanks guys this worked perfect writing to a...

    Thanks guys this worked perfect writing to a higher Priority with it as a numeric writable.

    The only other issue I was having is that I am trying to send a command to the Heat Valve on a Warm_up...
  14. Replies
    13
    Views
    388

    Thanks for the help guys

    Thanks for the help guys
  15. Replies
    13
    Views
    388

    Ok cool tonight ill have to give that a try. I...

    Ok cool tonight ill have to give that a try. I might not have been using a high enough write priority when I did it originally. I was attempting to write at 16. And it would go orange with a write...
  16. Replies
    10
    Views
    422

    Good for you man keep it up! All I can say is...

    Good for you man keep it up! All I can say is just dont get discouraged even when things add several more greys to the beard and less hairs to the head!

    I am also new to the controls trade and was...
  17. Replies
    13
    Views
    388

    When you say to add the point as an iutput do you...

    When you say to add the point as an iutput do you mean to just add it as a numeric writable? I dont think I can change the AI to an AO persay since the address is AI. I understand what you mean with...
  18. Replies
    13
    Views
    388

    Dang got a read fault on those points. Thanks for...

    Dang got a read fault on those points. Thanks for the try.
  19. Replies
    13
    Views
    388

    Awesome thank you I, will try this. I tried the...

    Awesome thank you I, will try this. I tried the sp high and low at adf 127 and adf 128 but this sounds more promising. Thanks a million
  20. Replies
    41
    Views
    4,262

    If at all possible could I get a copy also. It...

    If at all possible could I get a copy also. It would be greatly appreciated!
  21. Replies
    13
    Views
    388

    VMA1420 Wc-adjust

    I have a couple hundred VMA1420/1430s that have the warm cool adjust sliders on the zone sensors that I am integrating into a few Vykon Jace 700s.

    Is there a point or set of points I can write to...
  22. Replies
    1
    Views
    121

    Ok turns out even though the point has two states...

    Ok turns out even though the point has two states it is enumerated blah. Hope this helps the next guy.
  23. Replies
    1
    Views
    121

    Mapping SW-MODE UNT BI4 to Jace

    Im having an issue trying to map a point to switch between summer and winter on a bunch of UNT controllers. They look fine with boolean point selected but as soon as I try to make them writeable they...
  24. Replies
    9
    Views
    456

    I like to follow things up with solutions to the...

    I like to follow things up with solutions to the questions I ask to help others.

    This is what I found: because I was using an XT module and it had no PMs or DCOs connected to it, and you cannot...
  25. Thread: Dx9100 PLC

    by leakcheck
    Replies
    10
    Views
    507

    Well let me explain why I am trying to figure...

    Well let me explain why I am trying to figure this out. We removed 2 boilers out of 6. I just wanna make sure after I change the logic by removing the 2 boilers it will still work. I figured trying...