    No the ADX software won't talk to BACnet. It uses...

    No the ADX software won't talk to BACnet. It uses SOAP connections to talk to the NAEs. The NAE-8500 series, which is an NAE engine working on a server machine, can do BACnet but not do everything...
  2. Replies
    11
    Views
    311

    The ADX does not support BACnet natively nor does...

    The ADX does not support BACnet natively nor does it support OPC that I have ever seen. JCI just came out with a product called ODS which is a BACnet operator workstation. Otherwise you would need to...
  3. Bigguy158 you are correct. Looked back at my...

    Bigguy158 you are correct. Looked back at my files. 1.6.0_21 is for 5.1. But IE 10 will not work at all. I am pretty sure that is your main issue.
  4. Thread: METASYS ADS

    by NickDeal
    Replies
    31
    Views
    881

    If you log into the NAEs under the NAE focus tab...

    If you log into the NAEs under the NAE focus tab in Advanced View it will show if the ADS is online to the NAE. To check whether you are using DHCP you need to log into the NAE and under the network...
  5. Metasys at the version you are at, guessing from...

    Metasys at the version you are at, guessing from the Java version 4.1, was never designed to run on IE 10. They are very specific about browser version with Metasys. I am assuming it is a 32 bit...
  6. Thread: METASYS ADS

    by NickDeal
    Replies
    31
    Views
    881

    Is the ADS online to the NAEs? Has something...

    Is the ADS online to the NAEs? Has something recently changed like an upgrade, IP address, NAE Name? Have any firewall ports been recently changed on the network?
  7. Replies
    3
    Views
    261

    Depending on the version of the NAE it required a...

    Depending on the version of the NAE it required a certain IE version to work. Before they switched to the Launcher I think the highest it would go is IE8.
  8. Replies
    30
    Views
    5,666

    There is not a way to get a value from Insight or...

    There is not a way to get a value from Insight or a panel unless you are storing the value locally. The panels don't store any last values but will poll the TEC for values. From what I have seen and...
  9. Replies
    4
    Views
    229

    Yes, you can link the fan status or commands to a...

    Yes, you can link the fan status or commands to a fan animation. There is a large library very similar to the one in Insight for animations. The only catch is they can take a bit longer to start if...
  10. Replies
    4
    Views
    229

    I have seen and built very nice graphics with...

    I have seen and built very nice graphics with FINlite. They are not as functional as full blown Insight or other large scale BAS graphics are, but they report data and allow you to change the values....
  11. Replies
    1
    Views
    169

    You should be able to swap the ALN settings, but...

    You should be able to swap the ALN settings, but the panel will coldstart. If it was on the FLN it was acting as a UC most likely. If you have Insight the panel would appear as a TEC with an app...
  12. Replies
    3
    Views
    257

    I have not used Datamate, and at least in our...

    I have not used Datamate, and at least in our branch no one is familiar with it. If there is an Insight machine you can upload the MBC and then do a backup that way. A Siemens person would use Comm...
  13. Siemens has P1 which is their proprietary EIA-485...

    Siemens has P1 which is their proprietary EIA-485 protocol. Most companies use Master devices on the MSTP level, but Siemens TEC controllers can be set up to do Slave as well. A Siemens PXC device...
  14. N2 is not BACnet. I am assuming you are talking...

    N2 is not BACnet. I am assuming you are talking about MSTP. Siemens has controllers that operate on the MSTP level. They can exist on the same wire as other MSTP devices as long as the communication...
  15. Not Dingman, but RENO has to be licensed on the...

    Not Dingman, but RENO has to be licensed on the Insight Server you are using. If it is there is a button on the Main Menu for Remote Notification.
  16. Replies
    11
    Views
    505

    PTECs can be loaded and edited using Insight 3.13...

    PTECs can be loaded and edited using Insight 3.13 before that it took a combination of files and a command line tool. They integrated the PPCL stuff into 3.13. I don't think Desigo CC has the...
  17. Replies
    11
    Views
    505

    You can use Terminal Emulation to do it. It is...

    You can use Terminal Emulation to do it. It is pain. You can also have Siemens install the webserver in the PXCs. This is free and is what installs the Apogee Editors. You can do everything but...
  18. Replies
    11
    Views
    505

    No idea. I do know that whenever I load it up on...

    No idea. I do know that whenever I load it up on my laptop it my RAM usage immediately goes from 2-3 GB to about 12 GB. And it runs like piss on the Core i5 that I have.
  19. Replies
    11
    Views
    505

    If it is South America you should have the choice...

    If it is South America you should have the choice of either. Desigo Insight is mostly a European product but can be used in different areas of the world. If it is a new installation you will probably...
  20. Replies
    11
    Views
    505

    I am assuming you are US based and you mean...

    I am assuming you are US based and you mean Desigo CC otherwise in the rest of the world they call Insight Desigo. If you are using Desigo CC graphics are created using the Desigo CC program, but you...
  21. BACnet is becoming the industry standard for the...

    BACnet is becoming the industry standard for the most part. Siemens is pushing you that way because they never did LON very well and haven't pursued the protocol since the last iteration of their...
  22. Replies
    6
    Views
    249

    Yes with that option you will always output 20%...

    Yes with that option you will always output 20% even though on CCT and in Metasys it will show 0%. The hardware value below the output value show the actual value of the output.
  23. Replies
    3
    Views
    241

    From the Manual: This module is designed for the...

    From the Manual:
    This module is designed for the sequencing the dehumidification process. While dehumidifying, the dehumidification
    devices are controlled based on the return or zone air relative...
  24. Replies
    6
    Views
    249

    There are 2 ways to do this using CCT. The...

    There are 2 ways to do this using CCT. The easiest way is to go to the output and under details change the Hardware minimum out value to 20% instead of 0. This will force the controller to output 20%...
  25. Replies
    5
    Views
    288

    The interstage delay on and off timers prevent...

    The interstage delay on and off timers prevent the next stage from energizing or de-energizing until the interstage timer has expired. The interstage on timer for Stage 1 controls the elapsed time...
  26. Replies
    5
    Views
    288

    The interstage delays dictate how long the BO...

    The interstage delays dictate how long the BO will go before activating or deactivating after sequencing. An example if you have an interstage on delay of 10 minutes and there is one chiller running...
  27. You can assign relays to the groups. When you map...

    You can assign relays to the groups. When you map out the points all you get is the groups. So I could have Relay 5, 7, and 8 all mapped to group 1. BO 1 on the N2 side would turn on group 1 turning...
  28. There will probably not be a default point map...

    There will probably not be a default point map for the Triatek panel. Those panels are set up using LPPK software and can be done in a multitude of ways. The only points you can get out of it are BOs...
  29. Replies
    2
    Views
    347

    Yes, the space temp sharing is done in the NAE....

    Yes, the space temp sharing is done in the NAE. On the NAE you will either have a global share for each of the space temps or one or more LCT processes to do the sharing. When you release the...
  30. I assume that you have tried to force stroke the...

    I assume that you have tried to force stroke the valve from Insight/DesigoCC or WCIS if you have it. You can try cycling power to see if the valve will stroke. Other than that maybe clearing the...
  31. Replies
    6
    Views
    384

    The program files? They are just text based i use...

    The program files? They are just text based i use notepad.
  32. Replies
    33
    Views
    2,425

    For the BACnet side of the Talon line it is just...

    For the BACnet side of the Talon line it is just the same as what Siemens itself sells. PXC16,24,36s and PXCMs with TX/IO modules. From talking to a trainer earlier this week Talon View is basically...
  33. Replies
    2
    Views
    230

    Which documentation are you looking at? Total is...

    Which documentation are you looking at? Total is supported on BACnet points as of the Rev 6 manual that I have.
  34. Replies
    8
    Views
    547

    But it has to be mentioned that BACnet/IP was not...

    But it has to be mentioned that BACnet/IP was not fully functional at the revision that the NAEs are at. They didn't become fully BACnet compliant until 3.0 and I believe fully BTL Certified until...
  35. Replies
    5
    Views
    302

    I usually set it for 127. It should default to...

    I usually set it for 127. It should default to 127 but if its been changed it should be changed back.
  36. Replies
    5
    Views
    302

    Other than checking all of the BACnet settings in...

    Other than checking all of the BACnet settings in BACstac and the BLN not much there. Do you have autodiscover turned on for the BACnet BLN? If so if the PTEC is setup properly and you do send a...
  37. Replies
    3
    Views
    251

    You must log into the panel with a high level...

    You must log into the panel with a high level user. If it is an older panel high, high usually works. Just HMI without login gives you the display only option.
  38. Replies
    3
    Views
    251

    You can HMI into the panel and the first options...

    You can HMI into the panel and the first options is Time from there you can change the date and time.

    If you have access to the Insight Server in System Profile you can go into the panel and...
  39. Replies
    5
    Views
    302

    Is the PTEC setup to be a master? If the TECs...

    Is the PTEC setup to be a master? If the TECs aren't setup as master the PXCM won't act as a BACnet router and route the PTEC out to the IP network side of the controller. A lot of jobs have the TECs...
  40. Replies
    6
    Views
    416

    http://www.tsi.com/Airborne-Particle-Counters/ ...

    http://www.tsi.com/Airborne-Particle-Counters/

    Give them a call didn't look too much into options but I'm sure they have something.
  41. Replies
    3
    Views
    253

    http://cgproducts.johnsoncontrols.com/MET_PDF/6932...

    http://cgproducts.johnsoncontrols.com/MET_PDF/693205.pdf?x=85#xml=http://cgproducts.johnsoncontrols.com/search_lit.aspx?cmd=pdfhits&DocId=7484&Index=C%3a%5cinetpub%5cwwwroot%5c72%2e3%2e145%2e66%5cquic...
  42. Replies
    3
    Views
    253

    http://cgproducts.johnsoncontrols.com/MET_PDF/6893...

    http://cgproducts.johnsoncontrols.com/MET_PDF/6893100.PDF?x=85#xml=http://cgproducts.johnsoncontrols.com/search_lit.aspx?cmd=pdfhits&DocId=7477&Index=C%3a%5cinetpub%5cwwwroot%5c72%2e3%2e145%2e66%5cqui...
  43. Replies
    8
    Views
    547

    I would say that you probably can't use the FX...

    I would say that you probably can't use the FX Server and NAEs. From what I know of the way NAEs talk JCI would have had to modify the FX Server code to allow for the communication. Not saying that...
  44. Replies
    22
    Views
    3,320

    You have mail.

    You have mail.
  45. Replies
    22
    Views
    3,320

    You must have email in your profile for any help...

    You must have email in your profile for any help to be given.
  46. Replies
    1
    Views
    250

    You have mail.

    You have mail.
  47. The webstart switch usually doesn't work with 64...

    The webstart switch usually doesn't work with 64 bit. The problem is where Windows stores the java and where the webstart tries to launch it from. This will work with 32 bit and different versions of...
  48. Thread: HVAC Pro

    by NickDeal
    Replies
    44
    Views
    3,035

    VMs are basically another machine running along...

    VMs are basically another machine running along side the host machine. It uses the same resources as the host and forces the host to share. This is not so bad if you have a decent machine with a...
  49. Thread: HVAC Pro

    by NickDeal
    Replies
    44
    Views
    3,035

    I've used the Microsoft XP mode. If you have a...

    I've used the Microsoft XP mode. If you have a Pro version of Windows 7 you get it included. I run all the old JCI stuff and most of the new stuff in it.
  50. Replies
    21
    Views
    1,575

    That is a new level of awesome. Haven't seen one...

    That is a new level of awesome. Haven't seen one like that yet.