  1. Replies
    2
    Views
    357

    Need help with Liebert humidifier

    Does anyone have a wiring connection drawing for the infrared humidifier for an old Liebert FH199-A01. I have one with a dead short in the lamp circuit and the wiring has been changed from the...
  2. Replies
    0
    Views
    203

    YPAL problem

    I have a YPAL050CVC46BBCX. It has a tranducer package on 1 circuit only. The problem I'm seeing is the alarm led is lit and the pressures on the display are ???. Checked the transducers and got 3.5...
  3. Check the contactor, if the contacts are bad you...

    Check the contactor, if the contacts are bad you can get a current imbalance between phases in the compressor motor-causing overheating.
    Coolairman
  4. Replies
    6
    Views
    975

    Sounds like a classic restriction to me. You are...

    Sounds like a classic restriction to me. You are no doubt aware the metering device is in the ODU. When you pull the refrigerant out, you can put your pressure taps any where you want them.
    Good...
  5. Replies
    76
    Views
    4,750

    Sounds to me like the bearings are worn, main and...

    Sounds to me like the bearings are worn, main and or rod bearings. The excess clearance between the crankshaft and bearings wont allow oil pressure to stay up.

    Coolairman
  6. Replies
    17
    Views
    2,083

    Stupid costs extra

    Stupid costs extra
  7. Replies
    9
    Views
    516

    I assume you are changing the outdoor unit to a 2...

    I assume you are changing the outdoor unit to a 2 compressor setup where you will be running at approx. 50% capacity most of the time. I would get the information off the valve and check it out with...
  8. Replies
    9
    Views
    2,077

    They are just trying to discourage the copper...

    They are just trying to discourage the copper thieves.
  9. Replies
    34
    Views
    4,141

    Where is the cleanout?

    Where is the cleanout?
  10. Thread: High head

    by coolairman
    Replies
    7
    Views
    1,659

    Rheem units typically have a manual reset high...

    Rheem units typically have a manual reset high pressure safety-must have been bypassed.?
  11. Thread: Easy access

    by coolairman
    Replies
    14
    Views
    2,173

    Just because you can doesn't mean you should.

    Just because you can doesn't mean you should.
  12. Replies
    28
    Views
    1,481

    Coolairman

    Contactor coils typically burn up from a chattering condition, caused by lower than normal control voltage from having the wrong primary tap or a high resisistance short in the control wiring-not bad...
  13. Replies
    6
    Views
    900

    Coolairman

    You didn't mention if anyone worked on it before you got there.
    It sounds like you have a restriction in the filter drier or metering device.
    Sometimes inexperienced "techs" will add refrigerant...
  14. Replies
    19
    Views
    1,413

    Dont forget to check the hot gas bypass valve. If...

    Dont forget to check the hot gas bypass valve. If it is adjusted wrong your superheat will be high and your capacity will be reduced.

    Coolairman
  15. Thread: gasleak

    by coolairman
    Replies
    10
    Views
    3,150

    Dutch you work on some really cool hardware. I...

    Dutch you work on some really cool hardware.

    I have worked on a couple of Kraus chillers, very high quality.

    Regards

    Coolairman
  16. Replies
    13
    Views
    1,591

    Doug is right. I did the same thing in one of...

    Doug is right.

    I did the same thing in one of my buildings.

    I'm hoping the new tax incentive will push the building owner to purchas a new control system.

    Coolairman
  17. Replies
    12
    Views
    1,164

    Nisong: Sometimes if you are running an air...

    Nisong:

    Sometimes if you are running an air cooled package chiller, or any refrigeration system really, in ambient conditions below 20 F and the capillary tube on the low pressure safety switch is...
  18. Replies
    10
    Views
    1,381

    I didn't see any mention of worn or pitted...

    I didn't see any mention of worn or pitted contacts on contactor or starter.

    my 2cents.

    Coolairman
  19. Replies
    18
    Views
    1,585

    What I do when I suspect a scroll is running...

    What I do when I suspect a scroll is running backwards is check the current. It will be about 1/3 of rated load current while running backward.

    Coolairman
  20. Replies
    4
    Views
    724

    The r terminals on your sub base are for the line...

    The r terminals on your sub base are for the line side of your transformer's secondary. The rc terminal is for your cooling transformer and the rh term is for heat. These are seperated electrically...
  21. Thread: DASHPOT

    by coolairman
    Replies
    6
    Views
    1,061

    Many years ago, when I was an apprentice, some of...

    Many years ago, when I was an apprentice, some of the compressors 30 to 80 ton recips that I ran into had autotransformer or part winding start, starter gear on them.
    The dashpot acted as a time...
  22. Replies
    6
    Views
    553

    Put in a tee at the bottom of the riser with a...

    Put in a tee at the bottom of the riser with a threaded plug so debris can be cleaned out of the trap assy.

    Coolairman
  23. Replies
    9
    Views
    739

    There are a lot of good suggestions above....

    There are a lot of good suggestions above.
    Please allow me to add my 2 cents woth.

    As a long time hvac service guy I believe in the kiss principle-keep it simple ...

    Have a professional...
  24. Replies
    18
    Views
    1,228

    It's pretty typical for the company to purchase...

    It's pretty typical for the company to purchase the big ticket items and techs to purchase hand tools. Our company replaces worn or broken tools at the discretion of the first line supervisor.
    I add...
  25. Replies
    3
    Views
    725

    Dowadudda: Tell your customer that the direct...

    Dowadudda:
    Tell your customer that the direct fired heater is 100% efficient that is, there are no stack losses, every single btu goes into the make-up air stream.
    The only way he can save money...