02-20-2013, 09:56 PM
Thread: Need help with Liebert humidifier
by coolairman- Replies
- 2
- Views
- 357
Need help with Liebert humidifier
Does anyone have a wiring connection drawing for the infrared humidifier for an old Liebert FH199-A01. I have one with a dead short in the lamp circuit and the wiring has been changed from the...
-
01-02-2013, 07:59 AM
Thread: YPAL problem
by coolairman- Replies
- 0
- Views
- 203
YPAL problem
I have a YPAL050CVC46BBCX. It has a tranducer package on 1 circuit only. The problem I'm seeing is the alarm led is lit and the pressures on the display are ???. Checked the transducers and got 3.5...
-
11-30-2012, 09:18 AM
- Replies
- 10
- Views
- 814
Check the contactor, if the contacts are bad you...
Check the contactor, if the contacts are bad you can get a current imbalance between phases in the compressor motor-causing overheating.
Coolairman -
11-30-2012, 09:03 AM
Thread: samsung ac split in vacum
by coolairman- Replies
- 6
- Views
- 975
Sounds like a classic restriction to me. You are...
Sounds like a classic restriction to me. You are no doubt aware the metering device is in the ODU. When you pull the refrigerant out, you can put your pressure taps any where you want them.
Good... -
11-29-2012, 01:55 PM
Thread: oil pressure problem
by coolairman- Replies
- 76
- Views
- 4,750
Sounds to me like the bearings are worn, main and...
Sounds to me like the bearings are worn, main and or rod bearings. The excess clearance between the crankshaft and bearings wont allow oil pressure to stay up.
Coolairman -
08-04-2012, 09:52 PM
Thread: Can't breathe!
by coolairman- Replies
- 17
- Views
- 2,083
Stupid costs extra
Stupid costs extra
-
08-04-2012, 07:03 PM
Thread: single to a dual circuit
by coolairman- Replies
- 9
- Views
- 516
I assume you are changing the outdoor unit to a 2...
I assume you are changing the outdoor unit to a 2 compressor setup where you will be running at approx. 50% capacity most of the time. I would get the information off the valve and check it out with...
-
09-16-2011, 10:46 PM
Thread: Looks good, but how do I work on it?
by coolairman- Replies
- 9
- Views
- 2,077
They are just trying to discourage the copper...
They are just trying to discourage the copper thieves.
-
09-16-2011, 10:42 PM
Thread: Plumber hooks up drain
by coolairman- Replies
- 34
- Views
- 4,141
Where is the cleanout?
Where is the cleanout?
-
09-16-2011, 10:39 PM
Thread: High head
by coolairman- Replies
- 7
- Views
- 1,659
Rheem units typically have a manual reset high...
Rheem units typically have a manual reset high pressure safety-must have been bypassed.?
-
09-16-2011, 10:18 PM
Thread: Easy access
by coolairman- Replies
- 14
- Views
- 2,173
Just because you can doesn't mean you should.
Just because you can doesn't mean you should.
-
09-04-2010, 04:06 PM
Thread: 25 Ton Voyager
by coolairman- Replies
- 28
- Views
- 1,481
Coolairman
Contactor coils typically burn up from a chattering condition, caused by lower than normal control voltage from having the wrong primary tap or a high resisistance short in the control wiring-not bad...
-
09-04-2010, 03:07 PM
Thread: High pressure problem
by coolairman- Replies
- 6
- Views
- 900
Coolairman
You didn't mention if anyone worked on it before you got there.
It sounds like you have a restriction in the filter drier or metering device.
Sometimes inexperienced "techs" will add refrigerant... -
08-29-2010, 10:44 PM
Thread: Subcooling on Liebert Unit
by coolairman- Replies
- 19
- Views
- 1,413
Dont forget to check the hot gas bypass valve. If...
Dont forget to check the hot gas bypass valve. If it is adjusted wrong your superheat will be high and your capacity will be reduced.
Coolairman -
03-14-2006, 09:01 PM
Thread: gasleak
by coolairman- Replies
- 10
- Views
- 3,150
Dutch you work on some really cool hardware. I...
Dutch you work on some really cool hardware.
I have worked on a couple of Kraus chillers, very high quality.
Regards
Coolairman -
01-18-2006, 11:29 AM
Thread: Carrier-Parker VVT System Issues
by coolairman- Replies
- 13
- Views
- 1,591
Doug is right. I did the same thing in one of...
Doug is right.
I did the same thing in one of my buildings.
I'm hoping the new tax incentive will push the building owner to purchas a new control system.
Coolairman -
01-18-2006, 11:14 AM
Thread: CARRIER 30GTN025 PROBLEM
by coolairman- Replies
- 12
- Views
- 1,164
Nisong: Sometimes if you are running an air...
Nisong:
Sometimes if you are running an air cooled package chiller, or any refrigeration system really, in ambient conditions below 20 F and the capillary tube on the low pressure safety switch is... -
11-17-2005, 04:43 PM
Thread: 10 REASONS WHY MOTORS FAIL
by coolairman- Replies
- 10
- Views
- 1,381
I didn't see any mention of worn or pitted...
I didn't see any mention of worn or pitted contacts on contactor or starter.
my 2cents.
Coolairman -
11-17-2005, 04:25 PM
Thread: Three phase scroll
by coolairman- Replies
- 18
- Views
- 1,585
What I do when I suspect a scroll is running...
What I do when I suspect a scroll is running backwards is check the current. It will be about 1/3 of rated load current while running backward.
Coolairman -
11-01-2005, 10:41 PM
Thread: t-stat Question
by coolairman- Replies
- 4
- Views
- 724
The r terminals on your sub base are for the line...
The r terminals on your sub base are for the line side of your transformer's secondary. The rc terminal is for your cooling transformer and the rh term is for heat. These are seperated electrically...
-
11-01-2005, 10:22 PM
Thread: DASHPOT
by coolairman- Replies
- 6
- Views
- 1,061
Many years ago, when I was an apprentice, some of...
Many years ago, when I was an apprentice, some of the compressors 30 to 80 ton recips that I ran into had autotransformer or part winding start, starter gear on them.
The dashpot acted as a time... -
11-01-2005, 10:12 PM
Thread: quick trap question...Confused.
by coolairman- Replies
- 6
- Views
- 553
Put in a tee at the bottom of the riser with a...
Put in a tee at the bottom of the riser with a threaded plug so debris can be cleaned out of the trap assy.
Coolairman -
10-20-2005, 10:00 PM
Thread: upgrading hvac system questions
by coolairman- Replies
- 9
- Views
- 739
There are a lot of good suggestions above....
There are a lot of good suggestions above.
Please allow me to add my 2 cents woth.
As a long time hvac service guy I believe in the kiss principle-keep it simple ...
Have a professional... -
10-16-2005, 01:10 AM
Thread: What is your shops tool policy?
by coolairman- Replies
- 18
- Views
- 1,228
It's pretty typical for the company to purchase...
It's pretty typical for the company to purchase the big ticket items and techs to purchase hand tools. Our company replaces worn or broken tools at the discretion of the first line supervisor.
I add... -
10-16-2005, 12:55 AM
Thread: Pasint booth
by coolairman- Replies
- 3
- Views
- 725
Dowadudda: Tell your customer that the direct...
Dowadudda:
Tell your customer that the direct fired heater is 100% efficient that is, there are no stack losses, every single btu goes into the make-up air stream.
The only way he can save money...
Results 1 to 25 of 105