  1. Replies
    20
    Views
    1,134

    it's vented with 2 inch 35 feet total with...

    it's vented with 2 inch 35 feet total with fittings I went there today made sure there was enough pitchback on the vent pipe also thinking if there was built up water when the inducer shut off any...
  2. Replies
    20
    Views
    1,134

    i am going there in the morning to see what i find

    i am going there in the morning to see what i find
  3. Replies
    20
    Views
    1,134

    No water in collector box.I pull inducer and...

    No water in collector box.I pull inducer and drain it it did this a week ago and I checked it 3 days ago and everything seemed to be draining fine I could not hear any water in inducer
  4. Replies
    20
    Views
    1,134

    Flu is pitched with no standing water in...

    Flu is pitched with no standing water in pipe,might locate trap at collector box it runs for a week that has me stumped
  5. Replies
    20
    Views
    1,134

    Lennox el296v drainage issue

    I have a el296070 furnace that runs fine for 2 weeks and then the inducer fills with water and shuts the unit down.The trap is not installed at the collector its at the rear of the furnace about 30"...
  6. Replies
    1
    Views
    148

    Coleman roof jack question

    I am changing a coleman model number 4084a656 to an updated model number dgaa075bdtb and need to know if the roof jack jacks are compatible?The one thats there is in great shape and changing it is...
  7. Replies
    2
    Views
    215

    Lennox vent termination kits

    Anyone using the diversitech hvent2 or hvent3 for vent terminations?There half the cost of the lennox ones.
  8. Replies
    5
    Views
    405

    ICP pressure switch issue

    Icp mod n8npm050b from 2006,the burner lights for 20 seconds and goes out.Flame sensor was good check pressure switch operation which closes at -.58 and goes to .-64 but when the burner lights it...
  9. Replies
    7
    Views
    419

    I will do that Jeep Sent from my Torque using...

    I will do that Jeep

    Sent from my Torque using Tapatalk
  10. Replies
    7
    Views
    419

    Thanks dawg i updated my profile and sent you a...

    Thanks dawg i updated my profile and sent you a message also
  11. Replies
    7
    Views
    419

    LG LS090CE MINI SPLIT

    Does anyone have a troubleshooting guide or parts manual for this mini-split,the comp starts but the condensing unit fan motor never starts and the system shuts down in a few min.
  12. Replies
    3
    Views
    314

    Subcool reading was taken at the condenser ...

    Subcool reading was taken at the condenser

    Sent from my Torque using Tapatalk
  13. Replies
    3
    Views
    314

    76 degrees Sent from my Torque using Tapatalk

    76 degrees

    Sent from my Torque using Tapatalk
  14. Replies
    3
    Views
    314

    H/V CHARGING ISSUE

    New system startup 2.5 ton r-410 h/v system readings are,s/h=12,s/c=3 12 deg d/t, low side 118psi,high side 195 psi.The first floor is a walkout basement temp was 70 deg second floor 75 deg both have...
  15. Baldies got it right there I've had four leakers...

    Baldies got it right there I've had four leakers all c6 miles to the three years old

    Sent from my Torque using Tapatalk
  16. Thread: run cap question

    by splus
    Replies
    51
    Views
    3,259

    I would change it to the right one for sure what...

    I would change it to the right one for sure what will it harm the motor having the bigger one on there

    Sent from my Torque using Tapatalk
  17. Thread: run cap question

    by splus
    Replies
    51
    Views
    3,259

    run cap question

    Was on a call where there was a 7.5 cap on a motor that called for a 5mfd cap,was installed 2 years ago and running fine.Will this be okay if left like this?
  18. My company WAS installing nordyne equipment for...

    My company WAS installing nordyne equipment for 15 yearswith no issues until the microchannel systems came out.Most leakers dont show up until the second year and trying to find them have been not...
  19. Replies
    2
    Views
    200

    Thanks dawg Sent from my Torque using Tapatalk

    Thanks dawg

    Sent from my Torque using Tapatalk
  20. Replies
    2
    Views
    200

    Lennox c33 liquid line stub

    Is the 3/8od liquid line stub available as a part if so i need a part number,also the one that comes with the coil has a teflon o-ring on it do i need to install the o-ring that comes inside the coil...
  21. Replies
    2
    Views
    266

    So a standard 2.5 ring will work if OEM is larger...

    So a standard 2.5 ring will work if OEM is larger

    Sent from my Torque using Tapatalk
  22. Replies
    2
    Views
    266

    Trane blower motor question

    Trane part number moto4717 3/4 hp motor,need to know if a standard motor with 2.5 inch resilient rings will work I seem to remember some of these have 2/5/8 rings
  23. Replies
    12
    Views
    657

    The chimney has a tile liner in it now its been...

    The chimney has a tile liner in it now its been running fine for 2 days now told the customer we need to evaluate the chimney and possibly put a alum liner in it

    Sent from my Torque using Tapatalk
  24. Replies
    12
    Views
    657

    The chimney is on the outside of the house and we...

    The chimney is on the outside of the house and we have had a week off record cold here below zero wind chill

    Sent from my Torque using Tapatalk
  25. Replies
    12
    Views
    657

    Yes it will vent fine no spillage at the water...

    Yes it will vent fine no spillage at the water heater I haven't taken any draft reading yet its been venting and the boiler and then cycling for 24 hours

    Sent from my Torque using Tapatalk
  26. Replies
    12
    Views
    657

    After pulling the vent pipe off of the vent...

    After pulling the vent pipe off of the vent damper of the boiler letting it bent into the basement for a minute putting the vent pipe back on the damper in its been venting fine

    Sent from my...
  27. Replies
    12
    Views
    657

    The boiler is 125000 BTU with a 40,000 BTU...

    The boiler is 125000 BTU with a 40,000 BTU standing pilot water heater jimmy is on the outside of the house 8 inch tile lined

    Sent from my Torque using Tapatalk
  28. Replies
    12
    Views
    657

    It extends one inch into the flu I checked it a...

    It extends one inch into the flu I checked it a fee hours later and it was venting fine

    Sent from my Torque using Tapatalk
  29. Replies
    6
    Views
    597

    Triangle tube boiler with the trimax control is a...

    Triangle tube boiler with the trimax control is a nice boiler.W/M makes a fire tube boiler also which is pretty much the same heat exchanger.
  30. Replies
    12
    Views
    657

    Boiler draft issue

    Get to a no heat call on a natural draft spark ignition boiler and find the roll out under the draft hood tripped.Boiler fires and I notice its not venting at all as in the vent pipe after the vent...
  31. Thread: Wet Switches

    by splus
    Replies
    9
    Views
    778

    I have used a hair dryer but have found to just...

    I have used a hair dryer but have found to just replace it as most will trip if there is high humidity in the attic area there very sensitive after you dry them
  32. Replies
    2
    Views
    542

    LINE SET SIZE QUESTION

    Got a trane 4ttb3018 with a 4txc18 coil i serviced it a few years back and it has a 5/8suction with a 1/4 liquid line.another company looked at it as i was 5 days out and said the liqiud line size...
  33. Replies
    2
    Views
    480

    ADP TXV PART NUMBER

    adp #te36430c245b 5-ton made in 2007 its a r-22 coil with txv i need a r-410 valve i did have one from a trane 4txc coil but the threads dont match up anyone know the adp or trane part number for the...
  34. Replies
    4
    Views
    847

    Are the condensing units microchannel?I am going...

    Are the condensing units microchannel?I am going to install a few furnaces and see i do like the condensate trap setup on them compared to the nordyne ones getting plugged all the time.
  35. Replies
    4
    Views
    847

    LENNOX MERIT SERIES

    Any feedback on the lennox merit series? i have been looking into a lower end line which still has a branded name on it i know its an air-flo unit,i really cant go with payne,goodman ect as most of...
  36. Thread: FIRST HEAT PUMP

    by splus
    Replies
    1
    Views
    512

    FIRST HEAT PUMP

    Go to help a good friend do a startup on a heatup system today and when i was configuring the stat there was no outdoor sensor which i know is an issue.There is a honeywell th8320u1008 there,after...
  37. Replies
    9
    Views
    1,434

    80% sidewall venting

    Was on a call yesterday for a water heater changeout and the homeowner asks me to change the filter a quick look in the attic and there is a 2 year old 80% forced air funace sidewall vented with...
  38. Replies
    6
    Views
    2,401

    I did take all the hoses off and made sure...

    I did take all the hoses off and made sure nothing was inside them,the furnace did cycle two times and then three days later i have the same pressure switch error.
  39. Replies
    6
    Views
    2,401

    Nordyne pressure switch ordeal

    I started a a/c install 3 days ago furnace is a nordyne kg7tc 2-stage that was installed 3 years ago with no issues.While do the low voltage wiring with new stat i deside to start furnace and check...
  40. Replies
    24
    Views
    2,524

    its a microchannel coil in the air handler?there...

    its a microchannel coil in the air handler?there is a charging chart on the cover of the outdoor unit use that.i have had some issues with charging these but when you get it right you will fine and...
  41. Replies
    3
    Views
    603

    i figured as much and its 7/8 after that to the...

    i figured as much and its 7/8 after that to the coil
  42. Replies
    3
    Views
    603

    Multiple size line set on unit

    Did a pm on a trane system older 4 ton txc coil no txv and a 3.5 ton r-410 4ttb outdoor.the line set was just under 50 feet at the coil its 7/8 suction but the last 8 feet to the condensing unit was...
  43. Replies
    14
    Views
    1,604

    Thanks for all the good info,i am running into...

    Thanks for all the good info,i am running into alot of systems that the airflow is either way to high or set on low speed and with days of 90 degrees an above a system not set up right on...
  44. Replies
    14
    Views
    1,604

    Airflow and system capacity

    So if i have a 2 ton split system r410 with 700 cfm across the coil system charged correct with a 18 degree temp drop across the coil and i adjust airflow to 900 cfm adjust charge and have a 16...
  45. Replies
    18
    Views
    1,915

    This is a straight cool system,the customer...

    This is a straight cool system,the customer called after having a few days to think about it and said they understand this is a roll of the dice.another point i need to bring up is the outdoor unit...
  46. Replies
    18
    Views
    1,915

    according to the paperwork that came with the...

    according to the paperwork that came with the coil it uses the same txv for 2 thru 3 ton coils,its a aspen slab coil and the customer called and is willing to try and i mean try what ever i think i...
  47. Replies
    31
    Views
    3,409

    Is the coil a new c7 microchannel cased coil and...

    Is the coil a new c7 microchannel cased coil and if so did you add a txv or use the piston that came with the coil?if its a piston is it the correct size as i have a few of these out there and in the...
  48. Replies
    18
    Views
    1,915

    pressure dropped 4psi air temp only dropped 1...

    pressure dropped 4psi air temp only dropped 1 degree though
  49. Replies
    18
    Views
    1,915

    They totaly understand i am only going to offer...

    They totaly understand i am only going to offer maybe something that might work and it will be in writing/also i do see alot of systems around here with a 1/2 ton larger coil.
  50. Replies
    18
    Views
    1,915

    i put airflow on low and adjusted the charge that...

    i put airflow on low and adjusted the charge that was my first move
Results 1 to 50 of 490