Search:

Type: Posts; User: nasaguyjoe

Page 1 of 3 1 2 3

Search: Search took 0.02 seconds.

  1. Here's my set up: NAE is at 7.0 Integration...

    Here's my set up:
    NAE is at 7.0
    Integration trunk is set to #3 and network address is unique and set at 2483
    LIP-ME201 has a static IP and network address is set at 2483

    I can see the LIP...
  2. Yes lol bacnet devices Sent from my iPhone...

    Yes lol bacnet devices


    Sent from my iPhone using Tapatalk
  3. Loytec LIP-ME201 for Metasys Remote Field bus?

    Has anyone one set one of these up? I haven't found much information in the LIT file. Really confused how to set up the integration trunk.
  4. Replies
    6
    Views
    292

    Think I find something.. ...

    Think I find something..

    http://www.onsetcomp.com/products/kits/kit-ux90-kwh?multi=1&id=ux90-kit&&kits=1
  5. Replies
    6
    Views
    292

    Just a basic kWhr totalizator would suffice. They...

    Just a basic kWhr totalizator would suffice. They will be logging the data manually on rounds.
  6. Replies
    6
    Views
    292

    Ideally less the $500

    Ideally less the $500
  7. Replies
    6
    Views
    292

    Energy audit equipment on a budget?

    Doing an energy audit on some HVAC equipment and I'm on a really tight budget. I'm using cheap inductive hour meters on most of the fan and pump motors. Looking for an inexpensive way to monitor the...
  8. Yeah I'm going to work on that or try to start...

    Yeah I'm going to work on that or try to start filling in the gaps, I'm sort of self taught/trained so always something new. We have a lot of N2 hardware and the people who set that up ages ago...
  9. Solved: Sent all the captures to onicon and they...

    Solved: Sent all the captures to onicon and they worked on a firmware update and it seems to be working so far.
  10. Replies
    5
    Views
    639

    Damnit.. Relays it is.. Thanks for the input.

    Damnit.. Relays it is.. Thanks for the input.
  11. Replies
    5
    Views
    639

    Switching 24VDC LEDs with FEC outputs?

    Is there a trick to switching 24VDC on the binary & configurable outputs of an FEC? I have an led stack light that I'm trying to switch on and off and they switch on but not off I'm assuming this is...
  12. Wiring has been rung out and all settings triple...

    Wiring has been rung out and all settings triple checked.

    Lost tokens was mentioned and I'm looking at other places I have these meters. Heres the totals for the troubled trunks:

    #25- 10037...
  13. Okay pulled new captures using the JCI capture...

    Okay pulled new captures using the JCI capture tool. Each capture is about 8-10 minutes.

    Here's a quick synopsis of each trunk and problem.

    #25
    - NAE5510-1 with about a 1500ft bus, EOL...
  14. Good morning gents. I did some more reading and I...

    Good morning gents. I did some more reading and I wasn't using the mstpcap right I had the baud rate set incorrectly and wasn't letting it run long enough. Going to go recapture everything and I...
  15. Replies
    7
    Views
    1,760

    Did you ever come to a solution on this? I'm...

    Did you ever come to a solution on this? I'm running into a similar problem. Have a trunk with just 5 meters and after a while (days) they will all go offline. Then I have a trunk that has various...
  16. I went ahead and gave the device I had a shot...

    I went ahead and gave the device I had a shot seemed to work. After a bit of googling I found that wireshark doesnt support com port discover but found a little program mstpcap that creates a...
  17. Just getting back from being out of town and the...

    Just getting back from being out of town and the trunk went down again while I was away as well as two others... All of them have newly installed onicon steam meters in common. I'm going to work on...
  18. JCI Field Bus Diagnostic tab question & Non-JCI BACNet on Field Bus issue

    First Part:
    I have a fairly newly installed Field Bus installed and having some issues with it. The other day the Bus Health index went to 120 and all of the devices went offline. I restarted the...
  19. Yeah when I do a local NUT - I use the Netgear...

    Yeah when I do a local NUT
    - I use the Netgear FS105 Switch
    - Put in MAC address
    - I do PXE only
    - Select the disk image
    - Hit okay then power up the NAE

    My machine's network card is set to:...
  20. Also if you want to see what defaults are for...

    Also if you want to see what defaults are for other points view the point and go to the options tab.
  21. Bentail - Tried the wipe took a while to dig up a...

    Bentail - Tried the wipe took a while to dig up a CF card reader ha! No luck.. I was able to use the trunk parts on one that had a bad trunk so not a total loss.

    JCIman - got a 5510-0 to play...
  22. Little update.. the CF card on the memory problem...

    Little update.. the CF card on the memory problem one was not fully inserted. Inserted and took the update with no issues other than for some reason with the 7.0 update the metasyssysagent password...
  23. Can you shoot me a PM JCIman

    Can you shoot me a PM JCIman
  24. The oldest image I have is 4.1

    The oldest image I have is 4.1
  25. NUT tool is V. 6.5

    NUT tool is V. 6.5
  26. Also for the storage error I tried to nut it at...

    Also for the storage error I tried to nut it at 4.1 in the super off chance the NAEs case was changed and it was actually a 5510-0 and it gave me the same error.

    And the NIC Tool doesnt seem to...
  27. One stuck NAE & one flash storage error during NUT both 5510-1

    Hello folks having an issue nutting two NAE5510-1's. Just finished with another NAE5510-1 and a NAE35 earlier so I know its nothing to do with my computer settings. I've done this a dozen times...
  28. Replies
    2
    Views
    613

    Okay I have the all items expert tab on my ADX...

    Okay I have the all items expert tab on my ADX UI. How do I go about pulling the error from an NAE?605641
  29. Replies
    2
    Views
    613

    NAE Expert Mode? Getting in to it?

    I have an NAE55 thats randomly poping a General Fault. I've read on here that I need to get in to expert mode to view the fault. I've search on how to do this but I'm coming up empty. Found an old...
  30. Replies
    2
    Views
    304

    ZFR1811 Repeater radio update?

    I'm having a few random signal issues with some of my zigbee stuff. I've read everything should be at the same radio revision as the ZFR1800 or better. The LIT discusses how to update the ZFR1800...
  31. Slowly deleting N2 devices Clean way to save historical data? (Metasys)

    I have a bagillion N2 devices that I am slowly upgrading to FECs. Right now I just disable the old device when it's taken out of service but I'm a bit OCD and all of the red Xs on the trunk drive me...
  32. Good to hear I'm not special :cheers:

    Good to hear I'm not special :cheers:
  33. No and AIC seems to be apart of wattstopper now...

    No and AIC seems to be apart of wattstopper now and basically their support staff stopped responding to my calls/emails....
  34. Replies
    2
    Views
    427

    Thanks! awesome info.

    Thanks! awesome info.
  35. Replies
    2
    Views
    427

    Html to bacnet?

    We use Maximo on our site for asset management among other things. I've been asked to look at having our assets in maximo up/down status be relayed to our Metasys system. I was wondering is there...
  36. JCIman disregard I've managed to source the 6.5.5...

    JCIman disregard I've managed to source the 6.5.5 patch.
  37. It wont let me pm you.. Can you send the 6.5.5...

    It wont let me pm you.. Can you send the 6.5.5 patch via https://www.wetransfer.com/ ? if so my email is
    northjoe (at) gmail (dot) com
  38. JCIman I'm going to PM you.

    JCIman I'm going to PM you.
  39. Yeah the integrator is on the ADX. But I was...

    Yeah the integrator is on the ADX. But I was trying to see if I could do it standalone connected to my laptop but I only have 6.5.0 not 6.5.4. So I guess no dice.

    The trouble is I have to schedule...
  40. Does the latest Sullair Supervisor II support modbus natively?

    My subject line is wrong I thought I had the Supervisor II actually we have the Sullair WS controllers. But the same question stands. Will they support modbus? My rep is useless I've been waiting a...
  41. NAE at 6.5.4 - ADX at 6.0 - Laptop SCT at 6.5.0 - Need to work on the NAE

    So I just got a custom built integrator NAE/NIE from Johnson for my power meters. It has pre built device templates in the file tree that I need to copy and paste to add my meters. My problem is my...
  42. Thanks guys the archive from SCT saved his bacon.

    Thanks guys the archive from SCT saved his bacon.
  43. Restoring deleted graphic folder on ADX?

    One of my technicians called me in a panic today. He was working on some graphics and some how managed to delete one of our buildings graphics folder on the ADX. Is there any easy way of getting...
  44. Replies
    5
    Views
    1,325

    Thanks for the info Sent from my iPhone...

    Thanks for the info


    Sent from my iPhone using Tapatalk
  45. Replies
    5
    Views
    1,325

    Metasys 7 release date? Thoughts?

    I got a preview of 7 before the holidays. The new UI Looked pretty slick, very clean. Seems to be very very nice tailored summaries. I'm sure there will be a lot of work to get things standardized on...
  46. Replies
    6
    Views
    657

    If I do the first option will the output always...

    If I do the first option will the output always be set to 20%? So like if I'm not in cooling mode will I still be calling for 20% on the cooling valve?
  47. Replies
    6
    Views
    657

    Long story... short version is we have 70 year...

    Long story... short version is we have 70 year old large fan houses that use water spray(sort of like a swap cooler) system with a booster pump and we need to keep a minimum amount of water in the...
  48. Replies
    3
    Views
    591

    Dehumidification Sequencer CCT WTF?

    Can someone explain to me how the Dehumidification Sequencer works? Is it only designed to work in the North? I'm in South Louisiana where we have a good bit of humidity year round and it seems to...
  49. Replies
    6
    Views
    657

    Setting a Minium output in CCT?

    I have a chilled water valve that I need to go to 20% at the minimum when in T control. Is there a simple way to do this?
  50. JCI FC Bus Health Index correlating to device offline/online events WBT900 wireless

    I have some sewer lift stations I'm monitoring via metasys. I'm using a WBT900 MSTP server at the NAE and two WBT900 MSTP clients at the stations. Each client has a single FEC hanging off it to...
Results 1 to 50 of 137