  1. Replies
    5
    Views
    484

    I remember the average age in my journeyman class...

    I remember the average age in my journeyman class was late 30s. We just hired a tech in their 30's and she goes to school in a couple of months for level 1
  2. Replies
    7
    Views
    418

    Thanks, I have always replaced the guts of the...

    Thanks, I have always replaced the guts of the valve which is removing the top portion of the valve with the spring. I have never removed the bottom bellows where the refrigeration connection is....
  3. Replies
    7
    Views
    418

    This valve is on an ice machine and is not cost...

    This valve is on an ice machine and is not cost effective to pump out the machine and remove the valve. If I can just use a rebuild kit.
  4. Replies
    7
    Views
    418

    johnson controls penn water valve

    Question: I have recently repaired a V46AA valve. Guts were replaced.
    The bottom is leaking water. Under the brass water valve portion and above the refrigeration bellows.
    There are 4 torex screws...
  5. Sounds like this tech isn't very good at...

    Sounds like this tech isn't very good at refrigeration equipment. Anyone would never leave a unit like this till it was fixed.
  6. Replies
    45
    Views
    2,089

    lol

    lol
  7. yes this would normally be done asap. Unless you...

    yes this would normally be done asap. Unless you are located in an area that is remote with no part access.

    Wonder what type of refrigerant is in this unit.
    Wonder if the compressor was tested....
  8. Thread: heat load

    by ryan79
    Replies
    3
    Views
    435

    heat load

    Question on how much of a heat load does a VLT product in a gaming lounge ?
  9. Replies
    18
    Views
    967

    Try to pump down the compressor. Turn it off once...

    Try to pump down the compressor. Turn it off once it is in a vacuum. Pressure should hold and not rise.
  10. Replies
    13
    Views
    681

    it is good practice to change the capacitor when...

    it is good practice to change the capacitor when changing a motor.
  11. Replies
    18
    Views
    967

    condenser clean ? what kind of condenser is this...

    condenser clean ? what kind of condenser is this ? water or air cooled ?
    sounds like the compressor is going off on overload.
    Don't run a compressor with no refrigerant in the system. It requires...
  12. Thread: Old trane

    by ryan79
    Replies
    8
    Views
    469

    yes still see these around from time to time. ...

    yes still see these around from time to time.
    What is on the duct where the disconnect is mounted ?
  13. Replies
    10
    Views
    554

    Yikes, all this reading and it is just try to...

    Yikes, all this reading and it is just try to tighten the top water fitting. If that does not work then the fitting will have to be replaced. This includes reclaiming the refrigerant cutting the...
  14. Replies
    12
    Views
    630

    the most cost effective solutions is to purchase...

    the most cost effective solutions is to purchase a room dehumidifier. Anything beyond that is going to cost some big dollars.
    Setting this up so it automatically drains is key. This is so that you...
  15. Replies
    12
    Views
    630

    It depends on where you are located. This will...

    It depends on where you are located. This will help decide on what options to go with.
    outdoor climate is important
  16. Thread: HTP boilers

    by ryan79
    Replies
    1
    Views
    305

    HTP boilers

    I have had recently been called to a high rise apartment building. No hot water. They have 2 new HTP boilers. Found that the heat exchanger is ruptured in one of them.
    The building owners are...
  17. Replies
    11
    Views
    857

    In the newer homes here codes have changed. All...

    In the newer homes here codes have changed. All homes require HRV's due to the moisture from the building materials. Extreme weather in our area to. Summer can be 95+F and 100%RH Winter is -40F and...
  18. Replies
    11
    Views
    857

    What type of hardwood floors do you have. There...

    What type of hardwood floors do you have. There are only a couple that actually require higher humidity. Usually installed in the more tropical areas.
    The type of windows and outdoor temperature...
  19. Thread: Dectron help

    by ryan79
    Replies
    10
    Views
    850

    to get any service manuals contact your dectron...

    to get any service manuals contact your dectron rep or James Hogan at Dectron in Atlanta
  20. Replies
    4
    Views
    524

    Is the curb open down into the pool space ? are...

    Is the curb open down into the pool space ?
    are the ducts insulated and sealed ?
    Was there a start up report filled out and sent into the factory? If there was did the approve it?
    Every unit that...
  21. Replies
    1
    Views
    618

    HVAC/Refrigeration tech required

    Royal Mechanical Solutions requires a service tech.
    Any level apprentice will be considered. Service experience required.
    Great hourly rates and benefit plan.
  22. Replies
    2
    Views
    337

    Do you have anther sensor in the room to compare...

    Do you have anther sensor in the room to compare it to ?
    0% RH, I think my nose would bleed instantly.
  23. Replies
    2
    Views
    451

    carrier zone thermostats

    I have a building with an older Carrier zone system. Thermostats cat no.690040. These are the stats that have the rotary dial numbers 1-9 and letters A-F

    Problem that I am having is. I can not...
  24. Replies
    4
    Views
    350

    NuCal i have used it before. Pink in colour and...

    NuCal i have used it before. Pink in colour and works well. Have to dilute though
  25. Replies
    4
    Views
    350

    have used muriatic acid to clean in the past....

    have used muriatic acid to clean in the past. Works well but have to know how to dilute and monitor.
    There are other chemicals on the market that will work. Check with your local supplier
  26. Replies
    3
    Views
    370

    contact a water filtration place. They will get...

    contact a water filtration place. They will get you something designed for your water.
  27. Replies
    3
    Views
    509

    30F differential across the coil is a good start....

    30F differential across the coil is a good start. This is a dehumidifying number target.
    Air flow is another good thing to check. Too slow and it will freeze up.
    Air flow. Does it have turning...
  28. Replies
    1
    Views
    373

    http://www.aerco.com/Products/Water-Heaters

    http://www.aerco.com/Products/Water-Heaters
  29. Replies
    7
    Views
    827

    You should be able to get good service from EA as...

    You should be able to get good service from EA as they are in Calgary.
    You should have a gas ticket in order to put your hands on this. Insurance reasons
  30. Replies
    5
    Views
    735

    If you shut off all the vents that supply into...

    If you shut off all the vents that supply into the warehouse (not knowing how many or sizes of entire system) you could restrict the air flow and cause the unit to trip out on high limit during...
  31. Replies
    4
    Views
    652

    Location of the hair salon and its city by-laws...

    Location of the hair salon and its city by-laws could help you in what you may need.
  32. Replies
    7
    Views
    603

    The headmaster should be only installed on stage...

    The headmaster should be only installed on stage 1. (mechanical cooling)
    When it is cold enough outside stage 1 should be a set of outside air dampers (economizer that gives free cooling) The...
  33. Replies
    14
    Views
    1,647

    it all depends on the duct sizing. A 7.5 ton unit...

    it all depends on the duct sizing. A 7.5 ton unit can be up to 3800CFM.
    Be careful.
    get someone in to help you out and tell you what you have and what you need.
  34. Replies
    7
    Views
    603

    Usually only the stage 1 will have the headmaster...

    Usually only the stage 1 will have the headmaster control on it. As most of the time the second stage is not required at that operating temp.
    Stage 1 should cool the space during low ambient temps....
  35. Replies
    7
    Views
    603

    you will have to explain a bit more. What is...

    you will have to explain a bit more.
    What is the entire unit doing ?
    why do you say you think you need a hot gas bypass ?
  36. Replies
    7
    Views
    603

    It all depends on what temperatures you are...

    It all depends on what temperatures you are operating. How is it defrosting now ?
    Not enough information to help you yet.
    What is your problem or concern ?
  37. Replies
    12
    Views
    1,395

    Mechanics in our area are paid ranging low end of...

    Mechanics in our area are paid ranging low end of 32 (government jobs) to 45. plus benefits on top of that.
    that is commercial/industrial hvac and refrigeration.
    amazing how the numbers differ...
  38. Replies
    11
    Views
    1,671

    is it a mua cell heater ? Cracked heat...

    is it a mua cell heater ?
    Cracked heat exchanger. Have seen the panels blow off units before.
  39. Replies
    5
    Views
    775

    it is making ice. The freeze cycle sounds normal....

    it is making ice. The freeze cycle sounds normal.
    the first 5 min? When is this after the ice drops from a harvest ? Is this the water dump cycle ?
    What is the customer complaint ?
  40. The government is not in the business of training...

    The government is not in the business of training people.
    They usually pluck guys that are min 5 year journeyman from companies
  41. Replies
    12
    Views
    1,395

    I have found in the past that customers will...

    I have found in the past that customers will follow the tech if they move to another company. No matter what the company tries to do. The customer still feels that the tech is the one who they want...
  42. Replies
    4
    Views
    507

    Trane has 1.5 ton RTU 1 ton not available....

    Trane has 1.5 ton RTU
    1 ton not available. Unless you go split or possible to have them make some for you at a manufacture.
  43. Replies
    5
    Views
    756

    How is the parkade vented ? does it have exhaust...

    How is the parkade vented ? does it have exhaust and make up air ?
    How is that controlled ?
    If possible I would exhaust directly outside. Someone is bound to complain that their eyes hurt or...
  44. Thread: Dry O Tron

    by ryan79
    Replies
    6
    Views
    650

    I service over 250 dry o trons. What kind of...

    I service over 250 dry o trons.
    What kind of question do yo have ?
  45. Replies
    7
    Views
    727

    this sounds funny. Agree that they may have...

    this sounds funny.
    Agree that they may have missed something.
    Wonder what they meant by bad wire.
  46. Replies
    4
    Views
    646

    What is the location ? 7.5 tons seems like a...

    What is the location ? 7.5 tons seems like a small unit for all that.
    Sounds like you need someone to come in and spec you a new system. Or design build it.
    Either way it would be cheeper to...
  47. Replies
    1
    Views
    437

    what kind of sweating problem ? I have had lots...

    what kind of sweating problem ?
    I have had lots of problems with the first co coils. That exact one.
    Found that the evap coil clogs up due to placement. Behind the blower and does not allow it to...
  48. Replies
    1
    Views
    503

    can not read the model numbers. can you provide...

    can not read the model numbers. can you provide them by typing the in.
    What kind of information are you looking for ?
  49. Replies
    6
    Views
    529

    What kind of equipment is it on. What kind of...

    What kind of equipment is it on.
    What kind of compressor ? if it is a scroll it could be wrong rotation.
  50. Replies
    7
    Views
    573

    What kind of system do you have? Exhaust with MUA...

    What kind of system do you have? Exhaust with MUA ?
    RTU's ?
    Fan Coils ?
    Where is your smell located ? Hallways, bathrooms, suites.
    Are there any exhaust hoods in the building ?
    Not enough...