Search:
Type: Posts; User: jafridgedoctor
Search: Search took 0.01 seconds.
-
03-29-2012, 05:40 PM
Thread: Supermarket system changeout
by jafridgedoctor- Replies
- 6
- Views
- 492
Yes Ice, they plan on changing the cases as well....
Yes Ice, they plan on changing the cases as well.
Yeah I think they would want minimal disruption to their operations considering its one of their larger stores.
I was looking at the Hill-Pheonix... -
03-29-2012, 03:33 PM
Thread: Supermarket system changeout
by jafridgedoctor- Replies
- 6
- Views
- 492
Supermarket system changeout
Hi Everyone,
I have a potential customer that wants us to do a refrigeration system changeout.
Currently they have 3 Hussmann Protocol units.
Model # PH05PK-MFMFMFMFMF
another Model #... -
03-28-2012, 10:26 PM
- Replies
- 56
- Views
- 2,874
Otto8, Glad to see that you solved the problem...
Otto8,
Glad to see that you solved the problem in the end.
However,I don't think that this compressor is a 3 phase unit with the amps that you are pulling.
That 5amp reading is probably the... -
12-15-2011, 09:48 PM
Thread: Delfield Freezer
by jafridgedoctor- Replies
- 1
- Views
- 2,000
Delfield Freezer
Hey guys,
I have a Delfield freezer model #6525 that a customer has asked me to look on. I realized that it has been worked on a couple of times.
The nameplate says it uses R404a and is a 220v 50... -
03-18-2010, 06:58 PM
Thread: Smardt chiller & Turbocor training
by jafridgedoctor- Replies
- 3
- Views
- 680
Thanks Flange,I'll give them a call tomorrow.
Thanks Flange,I'll give them a call tomorrow.
-
03-17-2010, 08:36 PM
Thread: Smardt chiller & Turbocor training
by jafridgedoctor- Replies
- 3
- Views
- 680
Smardt chiller & Turbocor training
Hi Everybody,
Does anybody here know if Smardt will train you as an individual ? Meaning you are not with a company that is a distributor for them ?
I will be in Canada around the time they have... -
03-01-2010, 08:02 PM
Thread: New install of Condensing units.
by jafridgedoctor- Replies
- 100
- Views
- 10,993
Can't even begin to comment. YOU really did...
Can't even begin to comment.
YOU really did such an install despite knowing better ? -
12-30-2009, 10:38 PM
Thread: Stange Voltage readings
by jafridgedoctor- Replies
- 2
- Views
- 356
Transformer setup
Judging from the pics it looks like they did an "open delta" setup.That's where they use two transformers and two primary phases to give you three phase secondary,perfectly acceptable as long as the...
-
12-09-2009, 06:53 PM
Thread: Bottle cooler doors
by jafridgedoctor- Replies
- 6
- Views
- 559
Oh no,when I said fog I don't mean like wet...
Oh no,when I said fog I don't mean like wet condensation, I mean that between the panes of glass there is a solid white substance sticking to the glass. If you tap the glass you might see some flakes...
-
12-08-2009, 11:20 PM
Thread: semi-recips obsolete ?
by jafridgedoctor- Replies
- 8
- Views
- 548
By virtue of fewer moving parts,scrolls should...
By virtue of fewer moving parts,scrolls should have the better reliability factor.It's just that once there dead there finished,absolutely no fixing of them
-
12-08-2009, 11:05 PM
Thread: Bottle cooler doors
by jafridgedoctor- Replies
- 6
- Views
- 559
Thanks guys.
Thanks guys.
-
12-07-2009, 06:51 AM
Thread: semi-recips obsolete ?
by jafridgedoctor- Replies
- 8
- Views
- 548
semi-recips obsolete ?
Do you all think that recip semi-hermetics are now obsolete especially in a/c apps.Most new stuff that I see below a certain tonnage now all have scrolls.And anything above are screws. I only see new...
-
12-07-2009, 06:43 AM
Thread: Bottle cooler doors
by jafridgedoctor- Replies
- 6
- Views
- 559
Bottle cooler doors
Does anybody know why a glass door of a reach in would fog up.I have some units in storage that have gotten totally fogged up and some partially.They are not in operation and are stored outside.I...
-
11-27-2009, 06:28 PM
- Replies
- 16
- Views
- 2,376
Makeshift condenser
No they are not cooling the outdoors.What they have done is to use the air handler coil as additional condensing surface.Dont know why,maybe the original coil is partially damaged,or maybe they put...
-
11-20-2009, 09:40 PM
- Replies
- 16
- Views
- 2,376
Well in all fairness to them ,the unit is located...
Well in all fairness to them ,the unit is located in a restricted area.I was just able to stick my hand around the fence to get a picture.But you're right it should have some kind of protective...
-
11-19-2009, 09:32 PM
- Replies
- 16
- Views
- 2,376
Ultra-ultra-high efficiency condensing unit
Followed friend to supermarket the other day.While waiting in the parking lot this was what I saw at the back of the building.Their using an air handler as part of the condenser.This unit is being...
-
11-01-2009, 12:51 PM
Thread: Leaders are born and not made
by jafridgedoctor- Replies
- 25
- Views
- 936
This is exactly my belief too. Her husband,who...
This is exactly my belief too.
Her husband,who is my brother by adoption (mine by his father) has always been saying that I'm the one who is going to take over the business when they retire.They... -
11-01-2009, 12:17 PM
Thread: Leaders are born and not made
by jafridgedoctor- Replies
- 25
- Views
- 936
Quite so!! She likes to say that she thinks I'm...
Quite so!!
She likes to say that she thinks I'm just a follower.
I think I was taught in school that great leaders were once great followers,just can't remember if that was a quote from some great... -
11-01-2009, 11:42 AM
Thread: Leaders are born and not made
by jafridgedoctor- Replies
- 25
- Views
- 936
Leaders are born and not made
Was having a discussion with in law who also happens to be one of the directors for the company that I work. She basically is of this opinion and does not believe otherwise.
I would like to hear... -
05-05-2009, 09:50 AM
Thread: Adjustable Potential Relays
by jafridgedoctor- Replies
- 10
- Views
- 1,253
Universal Potential Relay
I ve been using the Supco PR-90 universal potential relay.That's what all the supply houses out here have anyways.They work on anything from 1/4hp-5hp, 110-240volts.Just plug and play,nothing to...
-
03-30-2009, 06:57 PM
Thread: Mini Split Question
by jafridgedoctor- Replies
- 3
- Views
- 544
All the mini-splits I know of...
All the mini-splits I know of (Mitsubishi,Fujitsu,Carrier etc)operate this way.You can set the fan speed to "auto" and it will vary the fan speed automatically as the unit approaches setpoint...
-
01-29-2009, 09:12 PM
Thread: Bacon grease gravy
by jafridgedoctor- Replies
- 13
- Views
- 1,086
Man I love fried rice the best kind IS made from...
Man I love fried rice the best kind IS made from leftovers.
That bacon thing does sound like a dead man walking though.
Personally I like to microwave bacon in a paper towel to collect the oil. -
11-14-2008, 10:20 PM
- Replies
- 18
- Views
- 890
I charged it by weight initially (16oz 404a) and...
I charged it by weight initially (16oz 404a) and let it run for about two hours, then I added more (not sure exactly how much) to provide cooling for comp as it seemed hot on the dome.Now the unit...
-
11-14-2008, 09:00 PM
- Replies
- 34
- Views
- 1,505
Quite TRUE on that one :D
Quite TRUE on that one :D
-
11-14-2008, 08:57 PM
Thread: Cap tube splicing
by jafridgedoctor- Replies
- 16
- Views
- 1,110
Whenever I had to splice captubes,I usually use...
Whenever I had to splice captubes,I usually use 3/16" copper about 1" long with the two captubes meeting in the middle. Make sure to blow Nitrogen through to make sure that tubes don't get plugged...
Results 1 to 25 of 47