    I also post this post in the Residential. I kinda...

    I also post this post in the Residential. I kinda think it is interesting to get feed back from you guys.

    Filtering the dirt in the air using water. If we use our chilled water spraying and have...
  2. Replies
    55
    Views
    6,627

    How about this dirt trapping system. We treat...

    How about this dirt trapping system.

    We treat the water say like the chiller does. Spray the water and let our return air pass through it. Pretent the air is like a car passing through the car...
  3. Replies
    6
    Views
    2,114

    Please find out, then let us help you.

    Please find out, then let us help you.
  4. Thread: totaline cg1000

    by stef
    Replies
    1
    Views
    863

    EAC the best if properly install, maintain, and...

    EAC the best if properly install, maintain, and usage.
  5. Replies
    6
    Views
    2,114

    You should not have any problem with burning...

    You should not have any problem with burning candles for your enjoyment. It is not like you just started it.

    I recommend you to use 4 inches pleated filter to catch the soot a litle better. This...
  6. Thread: york

    by stef
    Replies
    24
    Views
    1,997

    Miller2000, Let's go over all info you gave...

    Miller2000,

    Let's go over all info you gave us.

    You have a heat pump?

    What size (ton) unit is it?

    The piston you pull is from the indoor or ourdoor unit?
  7. Replies
    5
    Views
    2,380

    Dear cbkiteflyer, Keep your old unit, replace...

    Dear cbkiteflyer,

    Keep your old unit, replace the discharge temp sensor. If I am not correct, HS22 is the 12 SSER system.

    Don't let the unknowledgeable tech, who came to your house, scare you....
  8. Baldloonie, You are right on some HW...

    Baldloonie,

    You are right on some HW thermostat. But here he has a Chronotherm IV, which does not apply with your reasoning.
  9. Replies
    17
    Views
    2,549

    Tom1843, It is best of course to install TXV in...

    Tom1843,
    It is best of course to install TXV in any system. Especially your mismatch sytem.

    Migration of freon during the off cycle. Especially the fix flow rater type metering device. Freon will...
  10. Hey Beltbuckle, The answere is NO and Yes. ...

    Hey Beltbuckle,

    The answere is NO and Yes.

    NO - because the Y (compressor) terminal will be energized on BOTH heat call and Cool call.

    Yes - Unless you do ONE of the following:

    Option 1:...
  11. Thread: york

    by stef
    Replies
    24
    Views
    1,997

    Miller2000, I don't mean to be rude. If you...

    Miller2000,

    I don't mean to be rude. If you don't mind, tell us where exactly you put your gauge to read these number?

    Have fun
  12. Replies
    17
    Views
    2,549

    If you do this yourself for your own house, then...

    If you do this yourself for your own house, then I say go for it. 4 tons outdoor with 3.5 tons indoor - NO Problem if you at least put in an expansion valve. As for 78 feet of freon line, my...
  13. Thread: freon converting

    by stef
    Replies
    16
    Views
    1,978

    Dear hnil, I hope that you have worked on this...

    Dear hnil,

    I hope that you have worked on this compressor before and familiar with the components of this compressor.

    As told by westcoast, It will not be an easy task. And no R22 will not...
  14. Replies
    60
    Views
    4,528

    Don't let the SEER fool you. don't forget to...

    Don't let the SEER fool you. don't forget to consider your region of living.


    Example: If you are living in Minisota, It is not wise to choose a very high SEER comparing to a guy like me living...
  15. Thread: SEER

    by stef
    Replies
    4
    Views
    1,231

    SEER

    SEER is of course stands for SEASONAL ENERGY EFFICIENCY RATING.

    The simplest (but not an only formula ARI used) formula for SEER is:

    Winter days usage
    SEER = 1.2 x...
  16. contact your lennox dealer and ask for the...

    contact your lennox dealer and ask for the conversion kit, which includes orifices, and springs.

    Springs are to bereplaced for your gas valve since propane has higher pressure

    Orifices, which...
  17. Thread: Lennox 80 UHG

    by stef
    Replies
    23
    Views
    4,342

    PARTS CHANGER. Since you are good at replacing...

    PARTS CHANGER. Since you are good at replacing part after part. Might as well keep going to other part. Give us a step by step of problem you encounter so we can help man
  18. Replies
    7
    Views
    9,964

    C and R - Lowest C and S - Low S and R -...

    C and R - Lowest
    C and S - Low
    S and R - Highest and MUST be equal to the sum of the resistenace of C & R plus C & S
  19. If you want to call them burner, then I use that...

    If you want to call them burner, then I use that same term.

    Look at how they are close to each other. The burner is designed round and flat on each end. If you look at each one of them closely.
    ...
  20. Replies
    9
    Views
    2,397

    Steph, Too much information, no DIY, see forum...

    Steph,

    Too much information, no DIY, see forum rules.

    Bob



    ALL of this mus be done by a qualify technician. Please don't fix the heater by your self.
  21. Replies
    56
    Views
    6,703

    quote:...

    quote:
    --------------------------------------------------------------------------------
    Originally posted by stef
    High humidity out side has nothing to do with the service. ...
  22. Thread: MP39 or 409a??

    by stef
    Replies
    25
    Views
    11,455

    Dear Icehouse, Indeed R22 is used in low temp...

    Dear Icehouse,

    Indeed R22 is used in low temp application and I and no one else deny that. All I said is that R22 is not a friendly type of freon to use on low temp comparable to othe brand such...
  23. Replies
    7
    Views
    952

    The house has a lennox for 40 years, that serves...

    The house has a lennox for 40 years, that serves him and previous owner well. Do you think he goes with other brand????

    My question to Doc and IRA:

    Wehave a complete match system. But whitout...
  24. It is best to have a qualified service technician...

    It is best to have a qualified service technician out to check your heating system.

    I always train my technician that "when you make a mistake with an air condition repair, you can go back and fix...
  25. Replies
    56
    Views
    6,703

    Dear sir, I hope you get this message before...

    Dear sir,

    I hope you get this message before the repair. Once again, remove all old charge. PULL DEEP VACUUM AT LEAST 500 MICRONS. and weight in the BRAND NEW freon. You are good to go on the...