Search:

Type: Posts; User: cjpwalker

Page 1 of 20 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    7
    Views
    126

    Sounds like you're starting out as an installer. ...

    Sounds like you're starting out as an installer. Bring what's on the list - the company may provide some of the other tools that you need. You will end up buying more as you see what the senior...
  2. http://www.caseparts.com/Catalog/Shelving-Miscella...

    http://www.caseparts.com/Catalog/Shelving-Miscellaneous/Shelf-Clips
  3. 1. If you are a tech, get a manometer. If you...

    1. If you are a tech, get a manometer. If you are not, call one.
    2. Bend down and check your gas-hole, :) (orifice)
  4. There is an internal pressure relief valve inside...

    There is an internal pressure relief valve inside the compressor of your heat pump. When the pressure gets dangerously high it will open up preventing damage to the compressor and other components. ...
  5. Replies
    23
    Views
    533

    Not so much my method, just "the way" where I...

    Not so much my method, just "the way" where I work. As far as empties all over the place - you must go through a lot of refrigerant in a week... It seems like lately I've had mostly hotside,...
  6. Replies
    23
    Views
    533

    Hey, do what you want - I'm glad that your method...

    Hey, do what you want - I'm glad that your method works for you. It wouldn't for me... I don't really have room to pack around empties, nor do i want to pack empties up to the roof, into a kitchen,...
  7. Replies
    23
    Views
    533

    You know, that's a good question. He's not...

    You know, that's a good question. He's not purchasing refrigerant... I don't know the rule chapter and verse to tell you, though.

    The last couple of guys we have had have been students from our...
  8. Replies
    23
    Views
    533

    Your employer must have a different philosophy...

    Your employer must have a different philosophy than mine. He'd rather have a dock guy making 1/3 of my wage recover refrigerant while I'm out running service calls... Besides that I only carry one...
  9. Replies
    23
    Views
    533

    I would think that you're fine, but wow - I've...

    I would think that you're fine, but wow - I've never considered putting that much effort into it. I just leave my empties on the roof...:whistle:

    No, seriously, though, we have a guy in the...
  10. Replies
    26
    Views
    557

    As mentioned in your other thread you will need...

    As mentioned in your other thread you will need to test for the EPA Section 608 certification. Most trade schools offer this, otherwise you might check with a local parts wholesaler - I think...
  11. Replies
    6
    Views
    249

    I am not familiar with the Azure motor. I have...

    I am not familiar with the Azure motor. I have installed a few of the Evergreen motors and have found it to be a fine product. The motor is a universal application of Regal's "X-13" ECM motor that...
  12. Replies
    11
    Views
    798

    The days of no computers and flat-head screws......

    The days of no computers and flat-head screws... those old-timers paved the way and got it done!
  13. Replies
    16
    Views
    366

    The last recovery tank I got has a leak in the...

    The last recovery tank I got has a leak in the threads for the valve. If I ever get it filled I'll be sure to turn it in...:whistle:
  14. Replies
    17
    Views
    395

    The adapter I have came with my automotive quick...

    The adapter I have came with my automotive quick connect adapters. I got the whole set on amazon or ebay a few years ago for under 50 bucks. I've never had to use the cylinder adapter, though - I...
  15. Replies
    16
    Views
    366

    It's a good solid pump - I've got two. The only...

    It's a good solid pump - I've got two. The only difference from it and the Platinum is no blank off or gas ballast valve. I've seen both of them hit below 100 micron (according to a JB supernova...
  16. You can have em... Zero just about pisses me...

    You can have em... Zero just about pisses me off, especially if I'm trying to troubleshoot a live electrical circuit when I can't feel my fingers. Heaven forbid I have to gauge up to something and...
  17. Replies
    2
    Views
    144

    The only reference I can find at Lennox to that...

    The only reference I can find at Lennox to that specific model is from a spec sheet from 1985 (only specs and dimensions, no schematics or service info), and only as a Canadian installation (your...
  18. I know... just messin' with yuh. See post 5. ...

    I know... just messin' with yuh. See post 5. Can't straight up tell it in open forums, you know. Sign up for pro status, already!
  19. No kidding... :putergreet:

    No kidding... :putergreet:
  20. So to recap your diagnostic, the low voltage...

    So to recap your diagnostic, the low voltage breaker tripped when the blower started (or made to start). Then again when the blower started, then again immediately (was the fan/limit control already...
  21. Replies
    13
    Views
    294

    Always set to "D" - it's a callback preventer. ...

    Always set to "D" - it's a callback preventer. That and making sure you actually have a two-stage thermostat so that it can override to mechanical cooling if free cool doesn't keep up.

    That...
  22. The part where the sensor is will definitely be...

    The part where the sensor is will definitely be melted off by 60 degrees. However, the coil does not always defrost evenly - sometimes there are stubborn spots, and if they are left frosted over...
  23. Replies
    8
    Views
    489

    You most likely have issues with your duct...

    You most likely have issues with your duct system.

    What the tech did was the equivalent of flooring the accelerator because the parking brake is on - yes the car will go, but...
  24. How about R12? Grab a couple of automotive...

    How about R12? Grab a couple of automotive pounders for $50 on ebay - just make sure it's actual R12.
    Also, Coke might want their machine back...
  25. I have a prestige at home. Every time the power...

    I have a prestige at home. Every time the power was shut off at the AHU the thermostat would dump everything. Button cell battery was good...

    but

    the CONTACT for the button cell had broken...
  26. Replies
    21
    Views
    931

    I have used them for a couple of years and think...

    I have used them for a couple of years and think they're great! I set them against a magnahelic. I take specific steps to ensure they operate the same as OEM, and to make them tamper proof after...
  27. Replies
    41
    Views
    2,082

    I've got a few craftsman tools. One is a decent...

    I've got a few craftsman tools. One is a decent ball-end allen wrench set. I have replaced it for free at least twice after breaking or stripping one or more of them on a stubborn set screw.

    The...
  28. Replies
    9
    Views
    502

    I love new tools as much as the next guy, but...

    I love new tools as much as the next guy, but really, it's a bubble... I've been pretty happy with the Made in China with a Scotsman logo screened on it - free swag from a factory training (sales...
  29. Search youtube and you can see the manufacturing...

    Search youtube and you can see the manufacturing process for a conventional tube-fin coil - the fin sheets are pressed onto a bundle of "U" shaped tubes, the tubes are swaged to form a tight contact...
  30. Replies
    5
    Views
    366

    Variable speed blowers are ECM (electronically...

    Variable speed blowers are ECM (electronically commutated motor). The motor has 3 windings, and a rotor with permanent magnets glued to it. Speed is determined by the rate that the electronics...
  31. Replies
    9
    Views
    471

    There are only 4 parts there: the valve, the...

    There are only 4 parts there: the valve, the thermopile, the high limit, and the ECO lead wire (the leads and the fitting that slips between the thermopile and the magnet on the valve -- I think...
  32. Replies
    14
    Views
    657

    I don't do that many flares... but when I do,...

    I don't do that many flares... but when I do, they haven't leaked years later.

    I have only ever used the standard flaring tool (the YJ swage/flare kit that you are born with if you go into this...
  33. Replies
    5
    Views
    368

    Yup - I see a couple a year. I carry a universal...

    Yup - I see a couple a year. I carry a universal pressure switch so I can replace it on the spot and get the heat back on. I've seen old stuck switches, poor/hi resistance contacts, cracked...
  34. Replies
    17
    Views
    695

    This applies to a lot of commercial, too. For...

    This applies to a lot of commercial, too. For the managers, it's not their money, but it is often their year end bonus at stake. For owners it is their money. You've got to be the professional and...
  35. Replies
    64
    Views
    2,556

    Most common would have to be my Crescent Hammer,...

    Most common would have to be my Crescent Hammer, Screw-Pry, and Georgia Boot Panel Alignment tool. The 16-3 Extension Rope comes in handy sometimes, too.
  36. Replies
    20
    Views
    837

    "Well, nobody's called me to fix the heat yet...

    "Well, nobody's called me to fix the heat yet because you're too stupid to stop coming here..."
  37. If I had to guess, the JB has the same size...

    If I had to guess, the JB has the same size reservoir with a bigger pump "cartridge" in the 7cfm, displacing more oil, therefore reducing it's capacity...
  38. Open forum. But... dip-switch.

    Open forum. But... dip-switch.
  39. Replies
    32
    Views
    3,320

    Same here - I've never needed to replace one...

    Same here - I've never needed to replace one unless it was specified in a maintenance (Nieco flame broiler at a certain "gourmet" hamburger establishment). Clean out with torch tip cleaners and...
  40. Replies
    1
    Views
    194

    That delay is very common on newer equipment. ...

    That delay is very common on newer equipment. Some manufacturers give a fancy name like "quiet shift" or the like. The scroll compressor in your heat pump has a tendency to hammer very loudly when...
  41. Replies
    17
    Views
    830

    2000. Why are you getting gasses from a parts...

    2000. Why are you getting gasses from a parts house?? Go to a welding supply. We use Oxarc for oxy, acetyline, nitro, and co2.
  42. Replies
    10
    Views
    563

    For a crack I can see that, especially if you...

    For a crack I can see that, especially if you don't eliminate the stress on it. This was a hole burned into the copper.
  43. Replies
    10
    Views
    563

    Fill. Then replace the drier. Don't make it...

    Fill. Then replace the drier. Don't make it harder than it needs to be.
  44. Replies
    3
    Views
    338

    The control pictured is for the humidifier. The...

    The control pictured is for the humidifier. The control at your thermostat is to dehumidify in summer using the air conditioner. The chart on the humidistat is suggested to prevent condensation...
  45. Again - this is because the schedule is...

    Again - this is because the schedule is programmed to have fan "on." Read my previous post again, then re-program your schedules to fan "auto."
  46. Check your schedule. The 8000 (I assume you are...

    Check your schedule. The 8000 (I assume you are referring to the older green back-lit thermostat) allows you to set the fan to auto or on during the different scheduling periods...
  47. Replies
    3
    Views
    465

    Higher temp = more energy = more money...

    Higher temp = more energy = more money...
  48. Replies
    53
    Views
    3,585

    That's the "Nintendo" repair. Be sure to blow on...

    That's the "Nintendo" repair. Be sure to blow on the chip for good measure... Some Fireye gas controllers are like that, too.
  49. Thread: Pro

    by cjpwalker
    Replies
    2
    Views
    222

    http://hvac-talk.com/vbb/showthread.php?116113-How...

    http://hvac-talk.com/vbb/showthread.php?116113-How-to-apply-for-Professional-Membership
  50. Replies
    51
    Views
    4,546

    1/4 inch or 5/16??

    1/4 inch or 5/16??
Results 1 to 50 of 1000
Page 1 of 20 1 2 3 4