  1. The Supco is not as robust as the OEM or a 5-2-1...

    The Supco is not as robust as the OEM or a 5-2-1 start kit. I would not recomment a Supco in this application.
  2. Replies
    8
    Views
    344

    Most sytems can be retrofitted to different...

    Most sytems can be retrofitted to different defrost control boards. Retrofits are harder and take more time depending on specifics of your system.

    It would help to find an experienced ( + 8...
  3. Replies
    20
    Views
    1,021

    Shepherds crook here too. Use it several times...

    Shepherds crook here too. Use it several times per week.
  4. Replies
    25
    Views
    1,290

    Put it in test mode and check delta t. You have...

    Put it in test mode and check delta t. You have access to the coils to tell if they are clean. Clean them if dirty. They have sensors out the wazoo to tell you when something breaks. Have codes to...
  5. Replies
    2
    Views
    235

    I don't know your experience or knowledge level. ...

    I don't know your experience or knowledge level. How high is the head pressure and the type of refrigerant? What would normal pressures be at your ambient temperature?

    Close the side panel. Air...
  6. Carrier or Bryant with a two stage Bristol recip...

    Carrier or Bryant with a two stage Bristol recip compressor will stop when changing stages. Normal operation. It works at 100% when it spins in one direction. 50% in the other direction. Must come...
  7. Replies
    15
    Views
    699

    The faster the repair gets made, the better it...

    The faster the repair gets made, the better it is for you. Should have had a guy come out and fix it that day. Any delay seems like stalling tactics. Your customer is just watching out for their...
  8. There could be many different reasons the ac is...

    There could be many different reasons the ac is not cooling. Something may have broken, sometimes even a new car breaks soon after leaving the factory. I've had new parts that were bad straight out...
  9. Technical support said to change the ribbon...

    Technical support said to change the ribbon cable. I'd do as they suggest.

    Not specific to the Stulz, for those who hadn't seen many on high pressure lockouts in general: Was your amp draw on...
  10. Replies
    17
    Views
    1,288

    Sometimes you pay so little that it's not...

    Sometimes you pay so little that it's not possible to get what you expect.

    Unlike many professions, an AC and Heating company makes most of its income when there are extremes in weather. Demand...
  11. Replies
    5
    Views
    285

    As far as I know the Infinity control already has...

    As far as I know the Infinity control already has the dual fuel stuff programmed into it, lots of options. No need for a dual fuel kit.
  12. Replies
    461
    Views
    13,300

    Interesting thing about the history of abortion...

    Interesting thing about the history of abortion being legal in all 50 states. It was close to becoming illegal in a majority of them before ROE V WADE. The issue was losing in the states. State...
  13. Replies
    6
    Views
    442

    I don't deal much with Rhee/Ruud so I don't know...

    I don't deal much with Rhee/Ruud so I don't know what they're making today. We do alot of commercial repairs and replacements and still do a lot of 460/480v stuff.
  14. Replies
    6
    Views
    442

    Get the 480v unit and make things simpler. It...

    Get the 480v unit and make things simpler. It will free up time to do other work. Those little conversion details will eat your lunch and suck all the joy out of life if not bid into the job up...
  15. Replies
    26
    Views
    1,235

    Have a smart phone? Take a picture of the next...

    Have a smart phone? Take a picture of the next superheat charging chart you see, rename the picture to the brand model number charging chart.
    Collect them like baseball cards. Copy them to your...
  16. Replies
    39
    Views
    2,859

    Some Tranes used two different run capacitors in...

    Some Tranes used two different run capacitors in parallel for a trickle feed crankcase heat. One of them had a resistor across it and, that resistor bled current through the start windings using a...
  17. Replies
    11
    Views
    736

    It's possible to tie backup power to run anything...

    It's possible to tie backup power to run anything you want. The issue of concern is backfeeding the power grid and electrocuting someone while they're trying to fix a power issue. Interties into...
  18. I find the cost of housing is still affordable in...

    I find the cost of housing is still affordable in certain parts of Austin. Affordable is usually more than you want to pay.
  19. Replies
    6
    Views
    1,533

    Low cost AC trunk line. Could have been done to...

    Low cost AC trunk line. Could have been done to fix a problem with air distribution. I agree with Rodney28334. You can make it pretty and wall it off with 2x4's, sheetrock and paint.
  20. Have a company spray the underside of the roof...

    Have a company spray the underside of the roof deck with Heatblock Ultra radiant heat barrier. It will cut down on the radiation of heat off of the roof deck. The total space between the roof deck...
  21. The last guy out seems to get the blame for...

    The last guy out seems to get the blame for anything going wrong. I've seen a lot of different things break and they were all working a little earlier. It's disconcerting to have a component ...
  22. It's hard to determine what is causing the...

    It's hard to determine what is causing the problem without testing. A bad breaker or breaker connections inside the electrical breaker panel or equipment dsconnect are frequently overlooked by...
  23. Perhaps the emergency/auxiliary heat strips are...

    Perhaps the emergency/auxiliary heat strips are broken and have shorted to ground. I'd have to do a few checks.

    Sometimes breakers go bad and trip at amperage lower than the rating.

    I've...
  24. Replies
    20
    Views
    1,703

    Had two customers who DIY'd their HSI. The...

    Had two customers who DIY'd their HSI. The symptom for each was failure to light reliably and sometimes locked out the ignition control board. The new generic ignitor didn't sit right in the gas...
  25. Need Commercial HVAC Mechanics/Techs Austin Tx.

    My employer is looking for Commercial HVAC Mechanics/Techs with a minimum of 5 years of commercial experience.
    We work in the Austin Tx area and have steady work year round.

    Competitive wages and...
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event