    You need to remove the charge to the correct...

    You need to remove the charge to the correct subcooling level. By having the subcool higher than the manufactures recommended level you have increased the head pressure substantially, thus causing an...
  3. Replies
    10
    Views
    601

    Hey I get what you are getting at, but if you...

    Hey I get what you are getting at, but if you were the one who had to "crunch the numbers" you would be using every advantage you could also. I Also think your calculation is incorrect. Amp x volts =...
  4. Replies
    10
    Views
    601

    They use the ecm motor because it puts out less...

    They use the ecm motor because it puts out less "heat" and uses less energy so it meets the energy guidelines of the 2009 mandate.
  5. Replies
    47
    Views
    2,479

    I didn't think that once the 4 digit code was...

    I didn't think that once the 4 digit code was changed that the date code on the back worked anymore.... but you may be right that it is over-ridden if the date code is entered.
  6. Replies
    56
    Views
    3,152

    I can't believe you only own one recovery...

    I can't believe you only own one recovery cylinder......
  7. 3 flashes can mean "Pressure switch open or...

    3 flashes can mean "Pressure switch open or closed". If the pressure switch is shorted out or actually stuck closed it will force the room fan to turn on. You didn't by chance get the pressure switch...
  8. I always just use a needle nose pliers like my...

    I always just use a needle nose pliers like my leatherman tool. You can grip the sides of the cap with the large teeth towards the back of the pliers and loosen the nut.
  9. Replies
    14
    Views
    2,157

    Those c-clamps are probably designed for that...

    Those c-clamps are probably designed for that purpose........:whistle:
  10. So I have now read the rules for the AOP section...

    So I have now read the rules for the AOP section and now understand that I was flagged because I am not a professional member with a (*) after my name. Why weren't the other 4 members without (*)...
  11. No brand is immune to this. I have had it happen...

    No brand is immune to this. I have had it happen to two units. I sell Lennox and when I went to the factory last fall is was interesting to see that every unit gets pressure tested with helium gas,...
  12. Replies
    27
    Views
    1,558

    Tomatoes, onions, anything pickled (it's the...

    Tomatoes, onions, anything pickled (it's the vinegar that does it), jalapeņo peppers and anything salty also. Mix any of these vapors with the condensate that collects on the fins and it turns to...
  13. What happens if the clock is "out of time". Do...

    What happens if the clock is "out of time". Do you get to go over there and reset the time and charge them a $100.00?
  14. Replies
    11
    Views
    592

    Diddo....Works every time!!!

    Diddo....Works every time!!!
  15. Replies
    0
    Views
    299

    Climate Controls Evap Information

    Does anyone know where I can get the spec sheets for an older Climate Controls high profile evap. The model is HDC-200-1 if someone is able to look it up. Or direct me to a website. Thanks! P.S. I...
  16. Replies
    64
    Views
    7,349

    I have used them for years (Washer Specialties)...

    I have used them for years (Washer Specialties) and have had very good luck with them. The ship you item before 5:00 everyday and are great with returns if something does go wrong. Really good...
  17. Replies
    11
    Views
    1,361

    It helps lower the amp draw of the motor that...

    It helps lower the amp draw of the motor that way!! Forget about the head pressure!
  18. Sticky: I started in the HVAC business in 2000 when my...

    I started in the HVAC business in 2000 when my dad purchased a small business with about 12 employees. I was 16 at the time but have always been very "hands-on" even as a child. I started out mostly...
  19. Replies
    14
    Views
    1,299

    It is liquid injection cooling for the...

    It is liquid injection cooling for the compressor. That is a rotary style compressor and they can get very hot and cycle on thermal overload. Some have it and some do not. That is determined at the...
  20. Replies
    70
    Views
    5,581

    We had the same issue at work. Sold all of ours a...

    We had the same issue at work. Sold all of ours a long time ago. I would say that they are just fine if you didn't use them on every service call. And only used them once and a while.
  21. Replies
    41
    Views
    1,565

    I sell and service Lennox. I have never had to...

    I sell and service Lennox. I have never had to replace the compressor to resolve this type of issue. It is usually is a situation that is causing the suction line gas to be very warm or a low volume...
  22. Replies
    23
    Views
    1,393

    I have a thread that I started that has some...

    I have a thread that I started that has some great info on non-condensables. http://hvac-talk.com/vbb/showthread.php?548382-Non-condensables-in-a-system
  23. I use R416A all the time in "mobile...

    I use R416A all the time in "mobile refrigeration". I believe it also goes by the name FR12. It works great and I think that you can get it in the small cans like R134a comes in. The R12 compressor...
  24. Replies
    19
    Views
    1,973

    It took me almost a year for me to find these...

    It took me almost a year for me to find these things but I found these here in the states. They are made over in Sweden. I will get the website for you on Monday when I get to work.
  25. I just went and looked at the box that is...

    I just went and looked at the box that is identical to the one that you are dealing with. It has a KAM2-0075 compressor installed. I cannot understand why someone would install a smaller...
Results 1 to 25 of 66
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event