  1. Thread: Goodman Furnace

    by tek1
    Replies
    14
    Views
    1,293

    If it were some sort of blockage, would it...

    If it were some sort of blockage, would it gradually change? Seems like the pressure would be too low from the beginning. I am kind of leaning towards a cracked heat x or collector box where the...
  2. Thread: Goodman Furnace

    by tek1
    Replies
    14
    Views
    1,293

    Checked that, drawing FLA at .7"

    Checked that, drawing FLA at .7"
  3. Thread: Goodman Furnace

    by tek1
    Replies
    14
    Views
    1,293

    Goodman Furnace

    Hi guys,

    I have a GMT090-3A. I have no history on this equipment. This is in my home (just moved in) I still have heat. I am getting a pressure switch fault. The switch is supposed to open at...
  4. Replies
    14
    Views
    1,070

    Will look in to that. This one looks like it is...

    Will look in to that. This one looks like it is strictly an aquastat. I usually see them as two separate switches, good to know for next time.
  5. Replies
    14
    Views
    1,070

    Calling All Residential Boiler Techs

    A little background: This is a home we are currently renting. I have never worked on a residential boiler until now, I typically only work on commercial/industrial. The radiators started to feel a...
  6. Replies
    14
    Views
    1,387

    Good replies. I replaced all 6 pulleys today, all...

    Good replies. I replaced all 6 pulleys today, all units running the right CFM now. I am bringing some ice tomorrow and see how that works.
  7. Replies
    14
    Views
    1,387

    Not sure how much was put in each one. I have one...

    Not sure how much was put in each one. I have one cylinder with a vacuum on it, if I need more, I guess I need more... thanks for the input
  8. Thread: Please Fix My AC

    by tek1
    Replies
    35
    Views
    4,747

    Looks to me like the cap blew...and took the...

    Looks to me like the cap blew...and took the whole unit with it. :grin2:
  9. Replies
    14
    Views
    1,387

    All good points. A little more background. Just...

    All good points. A little more background. Just keep in mind, I was thrown in the middle of all this a couple hours ago. I was told company "A" came out and for some reason, increased the fan speed...
  10. Replies
    14
    Views
    1,387

    Recovering Refrigerant

    What is the best way to recover refrigerant while a unit is running? I am heading out to a site, tomorrow, that is supposed to have six RTUs that are all overcharged. All TXVs, non adjustable. My...
  11. Replies
    18
    Views
    1,558

    Barry Sanders

    http://youtu.be/hsFhZy9oxuk
  12. Replies
    5
    Views
    923

    Let us know when you find that gig.

    Let us know when you find that gig.
  13. Thread: Need some advice

    by tek1
    Replies
    15
    Views
    2,094

    Sounds like trouble. If the union finds out about...

    Sounds like trouble. If the union finds out about you, that could very well hurt your chances of getting in. Do the right thing by the union, go talk to them. They will appreciate that. Who said you...
  14. Replies
    25
    Views
    2,270

    Then again, my new service manager, who has "been...

    Then again, my new service manager, who has "been doin' this since i was in diapers", told me that high super heat was caused by refrigerant stacking up in the evap. What do I know?... :beat:
  15. Replies
    25
    Views
    2,270

    Maybe he is messing with your head? Maybe joking...

    Maybe he is messing with your head? Maybe joking around with you?
  16. Thread: Trane RTU

    by tek1
    Replies
    9
    Views
    879

    I was able to get back over there today. I fixed...

    I was able to get back over there today. I fixed the leak, repiped where the drier was in the discharge line, and added a LL drier to the proper place. I left it with a nitrogen charge overnight. I...
  17. Thread: Trane RTU

    by tek1
    Replies
    9
    Views
    879

    Well hopefully it didn't damage the...

    Well hopefully it didn't damage the compressor...I guess I'll find out when I eventually start the unit up.
  18. Thread: Trane RTU

    by tek1
    Replies
    9
    Views
    879

    xpuser, I am sure it's a drier. I read it right...

    xpuser, I am sure it's a drier. I read it right on the side of it.
  19. Thread: Trane RTU

    by tek1
    Replies
    9
    Views
    879

    Trane RTU

    Trane
    M/N TSC036A3REAO1E1000000A3B4A

    I was leak checking this unit today, and saw a LL drier on the compressor discharge. Was thinking someone screwed up because it's 3/8 and just assumed it...
  20. Replies
    3
    Views
    604

    This one really gets me...

    Out of a 255 pc. set, I lost a 3/8 drive, 6 pt., 8mm socket. It's a Craftsman and if anyone finds it please return it! How about you guys? :cheers:
  21. Replies
    24
    Views
    3,080

    I had it pulled, Safety first!:cheers:

    I had it pulled, Safety first!:cheers:
  22. Replies
    24
    Views
    3,080

    Flint.

    Flint.
  23. Replies
    24
    Views
    3,080

    yea, there was 11 total "vandalized".

    yea, there was 11 total "vandalized".
  24. Replies
    24
    Views
    3,080

    Good thing it's January in Michigan

    :eek:
    http://i224.photobucket.com/albums/dd306/derekc1218/IMAG0236.jpg
  25. Thread: A Little Venting

    by tek1
    Replies
    8
    Views
    1,021

    So true.

    So true.
Results 1 to 25 of 27
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event