  1. Thanks for reply. How would I go about...

    Thanks for reply. How would I go about identifying evap coil? I knew it had been replaced by the burned insulation and silphos drips on both lines. Owner confirmed.
  2. R22 unit Low side 83 High side 290 Vapor Line 58...

    R22 unit Low side 83 High side 290 Vapor Line 58 degrees should be 59 by slide chart. Liquid Line 114 degrees. SH 9 degrees. Req. SH 9.5 degrees.Subcooling 15 degrees. OD temp 84.5. ID Wet 64 Dry 74....
  3. Readings Good Unit Won't Satisfy After Cleaning

    Hired to Performed clean and check on Bryant 3 ton package unit. According to home owner the unit cooled really well the night before I arrived. Noticed water weeping out all around unit. Removed lid...
  4. Thread: pressure ports

    by Staggs
    Replies
    5
    Views
    750

    Acess fittings

    I have used a drill, but always come in from the bottom of the tubing and go slow to make sure fragments fall down and out.
  5. Replies
    22
    Views
    1,677

    Tried removing the yellow jacket today after the...

    Tried removing the yellow jacket today after the vac seemed to hang at the same point for a while. Saw a drastic diiference. Then took gauges out of the circuit and went from hose to "T" where micron...
  6. Basement space conditioning

    In order for a ac sytem to remove moisture from the air it has to pass across the evaporator coil in multiple passes. There typically isn't enough heat load in a basement for the air to pass through...
  7. Replies
    22
    Views
    1,677

    Appion

    I have used both Appion and Yellow jacket and have had good and bad results with both. Never had the Appion blow out, but I did with a Uniweld that I borrowed from a friend. The roll pin that holds...
  8. Replies
    1
    Views
    624

    What is considered posting?

    Hi all. After 30 years managing the Facilities Engineering and maintenance in multi-million dollar manufacturing operations, started my own HVAC business. Primary focus at this point is residential...
  9. Replies
    6
    Views
    804

    Not sure what you mean by post count. What is...

    Not sure what you mean by post count. What is someone posting to prove themselves. To answer your question my company did not install any of these units. We were called in after other companies had...
  10. Replies
    9
    Views
    2,040

    That makes since. Thank you for the explanation.

    That makes since. Thank you for the explanation.
  11. Replies
    9
    Views
    2,040

    Thanks for the response. The bullet is at the...

    Thanks for the response.
    The bullet is at the outdoor coil before the distributor. Back up the line from that, is the TXV which appears to be feeding the outdoor coil also. The way the bullet is...
  12. Replies
    9
    Views
    2,040

    Heat pump 3 metering devices

    Hoping someone can explain why Rheem heat pump would have three metering devices. Fixed device for indoor coil when evaporator. TXV and fixed feeding the outdoor coil. Usually see either or but not...
  13. Replies
    5
    Views
    458

    Just curious. I was going behind what is supposed...

    Just curious. I was going behind what is supposed to be two of the more successful companies in our area. According to home owner the previous service guys walked to the unit and said it's freezing,...
  14. Replies
    5
    Views
    458

    What I noticed on the scrolls was that they...

    What I noticed on the scrolls was that they wouldn't over pressure even with almost thriple the factory charge. Seemed like the scrolls were opening to allow refrigerant to pass and relieve pressure....
  15. Replies
    5
    Views
    458

    Scroll over charged

    Came across my 3rd scroll in as many weeks that has been overcharged. Readings all over the map and fluctuating before recover, evacuation and recharge. Two have air flow issues in the home that...
  16. Replies
    6
    Views
    804

    Scroll over charge

    Came across my 3rd scroll in as many weeks that has been overcharged. Readings all over the map and fluctuating before recover, evacuation and recharge. Two have air flow issues in the home that...