Search:

Type: Posts; User: hvaceric

Page 1 of 18 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    35
    Views
    5,941

    Smith Equipment Quickbraze little torch.

    Smith Equipment Quickbraze little torch.
  2. OP, check out the Cooper-Atkins MFM300. There is...

    OP, check out the Cooper-Atkins MFM300. There is a review of it around here somewhere. I recently got one and it's pretty much everything you want, as I have been looking for a similar tool. I...
  3. Replies
    59
    Views
    10,622

    A small piece of foil tape works great on the...

    A small piece of foil tape works great on the battery door.

    I like the 605 from Testo, but it was too easy to loose or forget. So I got the Cooper MFM300KIT-1 a couple of months ago, really like...
  4. Replies
    558
    Views
    56,891

    FYI, DC's are thermistor sensors. The wire was...

    FYI, DC's are thermistor sensors. The wire was pretty weak on several different iterations of the sensors. But the newest wire seems to be very durable. Most guys that are customizing them are...
  5. Replies
    558
    Views
    56,891

    Side by side, in clean conditions, they will...

    Side by side, in clean conditions, they will perform virtually the same. The thermocouple is much more susceptible to outside interference however, meaning electrical currents and RF transmissions. ...
  6. Has anyone tried the Cooper-Atkins MFM300 on...

    Has anyone tried the Cooper-Atkins MFM300 on critically charged systems?
    I tend to use temperature first before getting a set of gauges out of the truck, and don't work on much real small stuff, so...
  7. Replies
    22
    Views
    6,100

    Haven't tried any of the tactical pants yet. I...

    Haven't tried any of the tactical pants yet.
    I have one pair of the fire hose pants from Duluth Trading, the cargo work with kneepad pockets, they are ok but their kneepad inserts are lousy and...
  8. Replies
    68
    Views
    5,645

    Be very careful when using the k-type probes,...

    Be very careful when using the k-type probes, they can easily give you false readings with very little outside interference. The probes on the testo and Digi-Cool products are thermistor's,...
  9. Replies
    10
    Views
    993

    You ever notice that most of those awards are...

    You ever notice that most of those awards are given out to the company's products that advertise in the publications that give out the awards?
  10. Replies
    16
    Views
    1,821

    I sit corrected, I took mine apart to look at it...

    I sit corrected, I took mine apart to look at it and apparently the center valve on the Kwik-Charger does have some kind of a stem seal. That is the first Imperial valve I have had apart that did...
  11. Replies
    24
    Views
    2,792

    You can splice the clamps onto the AK900 plug,...

    You can splice the clamps onto the AK900 plug, the sensors are the same. The only difference on the temp sensors between the older units and the AK900 is the PLUG/SOCKET at the unit.
  12. Replies
    16
    Views
    1,821

    Yes, the large nut can cause that. The Imperial...

    Yes, the large nut can cause that. The Imperial manifolds use a diaphragm style valve, so there is not supposed to be any refrigerant contacting the stem, the large nut seals the outer ring of the...
  13. Replies
    16
    Views
    1,821

    Tighten down the big nut right behind the handle...

    Tighten down the big nut right behind the handle and see if that fixes the problem. Don't have time to explain it right now.
  14. Replies
    16
    Views
    1,821

    If it's coming from around the valve just get a...

    If it's coming from around the valve just get a big wrench and tighten the valve assembly back into the body. They can be worked loose by back seating the valve too hard. I have done it a couple...
  15. Replies
    16
    Views
    1,821

    Define leaking?

    Define leaking?
  16. Replies
    24
    Views
    2,792

    At this time there are no plans to include the...

    At this time there are no plans to include the stretchy velcro sensors with the AK900, they will be an accessory only.
    Also no plans at this time to make these with the old plug style either.
  17. Replies
    24
    Views
    2,792

    To clarify, there is a two valve, ball valve...

    To clarify, there is a two valve, ball valve style, manifold that comes with the AK900, this is not the Paradigm manifold that has been in the works for the past several years, and it is currently...
  18. Replies
    49
    Views
    3,865

    So essentially you raised the pressures to where...

    So essentially you raised the pressures to where you thought they should be for a given outdoor temperature by limiting the airflow on the condenser?
    How does that enable an accurate check of the...
  19. Replies
    558
    Views
    56,891

    The boards are very different between 1250 and...

    The boards are very different between 1250 and 900. Both however can tell if a sensor is hooked up and display the appropriate options on the screen based on what is hooked up.

    One problem you...
  20. Replies
    558
    Views
    56,891

    The wires are colored like the silicone, but are...

    The wires are colored like the silicone, but are a much stiffer insulation on the stock sensors.
    The wire on the stretchy velcro sensors is even tougher, it has a two wire insulated internal and...
  21. Replies
    558
    Views
    56,891

    Yeah, I hear ya on the manifold, it's looking...

    Yeah, I hear ya on the manifold, it's looking much better for that project though. The middle valves have been redesigned, so I have high hopes that the new version will be out as soon as testing is...
  22. Replies
    558
    Views
    56,891

    Don't know. But with the low price on the AK900,...

    Don't know. But with the low price on the AK900, I doubt it.

    Sounds like a great idea to try, this stuff is actually a cross between velcro and elastic, the back of the stretchy part sticks...
  23. Replies
    558
    Views
    56,891

    The plugs are different between the...

    The plugs are different between the 1200/1250/1600 and the 900.
  24. Replies
    558
    Views
    56,891

    Guessing by April. Pricing has not been...

    Guessing by April. Pricing has not been addressed yet, Brenda is thinking $75-100
  25. Replies
    558
    Views
    56,891

    They are hooked to an AK900. The sensors will...

    They are hooked to an AK900.
    The sensors will work work with any DC product, the included plug will only work with the AK900.
Results 1 to 25 of 439
Page 1 of 18 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event