  1. Replies
    7
    Views
    625

    As dobbin stated, you need to weigh the costs -...

    As dobbin stated, you need to weigh the costs - plus more information on why the compressor failed will help in the decision making process. If the compressor is a "burnout" there are more...
  2. The only issue I can think of would be the cost...

    The only issue I can think of would be the cost to collect the condensate and then get it back to the condenser. Aside from that, there isn't anything in the condensate that would negatively impact...
  3. Replies
    20
    Views
    1,703

    As stated earlier, the IMC doesn't restrict the...

    As stated earlier, the IMC doesn't restrict the length. Typically the length is specified in the drawings and project documents.

    If there is an architect involved then I would assume that there...
  4. Replies
    4
    Views
    1,266

    If you can see the home screen, push the advance...

    If you can see the home screen, push the advance button and select a reboot of the CCP - similar to cycling power to the panel. When the panel boots the memory EEPROM read/write function is very...
  5. Replies
    7
    Views
    1,117

    Sorry - to answer your other question, yes you...

    Sorry - to answer your other question, yes you can tell if coil was destroyed by chemical vs salt spray. The corrosion from salt spray will leave a white powder-like residue.
  6. Replies
    7
    Views
    1,117

    Salt water destroys coils and unless you purchase...

    Salt water destroys coils and unless you purchase the coil protection (special application at the factory and typically VERY expensive) the only defense is to wash the coil frequently with plain...
  7. Replies
    12
    Views
    1,549

    Nice find ascj

    Nice find ascj
  8. Replies
    12
    Views
    1,549

    In the first two pictures, the lines connected on...

    In the first two pictures, the lines connected on the back side of the unit aren't even serving as a drain.

    I've got no ideas except for the installer had extra PVC and didn't know what to do...
  9. Replies
    7
    Views
    1,730

    I recently switched jobs and had access through...

    I recently switched jobs and had access through my former employer. Just established access with my current employer on the Comfortsite webpage. Prior to that I was helped by a few on the boards here...
  10. Replies
    71
    Views
    5,187

    There have been a lot of posts with "CYA" as the...

    There have been a lot of posts with "CYA" as the reason for checking capacitors on a PM. While that is a valid reason, take it to the next level.

    When you check and document, things like...
  11. Replies
    23
    Views
    3,608

    Interesting problem... Each circuit is totally...

    Interesting problem...

    Each circuit is totally independent with the exception that they share the same air (and fans) entering the condenser coil. So if we're dealing with an intermittent part...
  12. Replies
    4
    Views
    733

    The pressures you were seeing and that amp draw...

    The pressures you were seeing and that amp draw still bothered me. I don't have the data plate from the unit, but the product data that I have shows the unit has 06E compressors and at 208/230 volts,...
  13. Replies
    7
    Views
    1,730

    You are correct that Trane bought out GE - or...

    You are correct that Trane bought out GE - or really vice versa now... I have my question answered and thank you all that took the time to read it.
  14. Replies
    4
    Views
    733

    Glad to hear you have the unit running again.

    Glad to hear you have the unit running again.
  15. Replies
    4
    Views
    733

    What is the amp draw on circuit A compressors?

    What is the amp draw on circuit A compressors?
  16. Replies
    4
    Views
    935

    Using a psychrometric chart, with the information...

    Using a psychrometric chart, with the information you provided, the dew point temperature in the room should be 57.5 F (14.2 C). More information would be required to calculate your other questions -...
  17. Replies
    7
    Views
    1,730

    GE Packed RTU Model Series BWC

    I am looking for the Product Data pertaining to this series of unit. Thought it would be easy to find online, but it is anything but. If anyone has this on PDF or can suggest a site for this...