  1. Replies
    7
    Views
    802

    Nice idea. The shame of it is that in this world...

    Nice idea. The shame of it is that in this world things like that are a necessity sometimes.
  2. Thread: Utility Cart

    by hvac69
    Replies
    3
    Views
    270

    Rubbermaid has one but I have never actually seen...

    Rubbermaid has one but I have never actually seen it in person. A bit pricy too.
  3. Replies
    12
    Views
    638

    Your second suggestion is what I explained. He...

    Your second suggestion is what I explained. He had an issue with the AHU folder in your instance showing the station properties when clicked as yours will as well. If he changes the target ord for...
  4. Replies
    12
    Views
    638

    I sent a private message now. Sorry forgot to...

    I sent a private message now. Sorry forgot to submit the message.
  5. Replies
    12
    Views
    638

    I sent you a private message

    I sent you a private message
  6. Thread: Tridium Alarms

    by hvac69
    Replies
    5
    Views
    222

    This should give you a basic idea. Add a numeric...

    This should give you a basic idea. Add a numeric out of range alarm extension under your space temp point. Create a link from your setpoint to the Out of Range Alarm Extension Offnormal High Limit...
  7. Replies
    124
    Views
    6,027

    Great idea loosing the manifold. Too many times...

    Great idea loosing the manifold. Too many times have I needed multiple manifolds to measure pressures on larger systems and had to move a digital thermometer around. The imanifold wasn't that...
  8. Replies
    22
    Views
    810

    Higher horse power motor will not have its...

    Higher horse power motor will not have its amperage rise if put in place of a lower one as long as the RPM is the same. RPM and fan design is what determines the amount of air being moved and HP...
  9. Thread: Aaon Wattmaster

    by hvac69
    Replies
    4
    Views
    220

    1111, 2222, 3333 are defaults respectively for...

    1111, 2222, 3333 are defaults respectively for each user level. If those dont work you will need to contact Wattmaster Technical support.
  10. Replies
    16
    Views
    1,015

    Metal Oxide Varisitor possibly?

    Metal Oxide Varisitor possibly?
  11. Replies
    9
    Views
    271

    Have you verified your flow pickup is actually...

    Have you verified your flow pickup is actually measuring a DP? I had a VAV that drove me crazy at a new site for me that was about 5 years old and then realized the plastic tee at the pickup did not...
  12. Replies
    9
    Views
    271

    Controller configured as pressure dependent...

    Controller configured as pressure dependent maybe? When you say the problem followed, how do you mean? Controller with nan value moved to another vav and same issue or another controller moved to the...
  13. Replies
    22
    Views
    810

    I have seen that more than once on Carrier units...

    I have seen that more than once on Carrier units and from experiencing the situation in you are in I buy OEM when Carrier is involved. Always best to match FLA as well.
  14. Replies
    12
    Views
    638

    To place it in the Nav tree. Basic and rough...

    To place it in the Nav tree. Basic and rough explanation.

    Open the Nav file in the editor, select new, set the display name, for our purpose name it RTUs, leave the target ord line and for now...
  15. Replies
    10
    Views
    1,735

    Never mind, found out what I needed

    Never mind, found out what I needed
  16. Replies
    10
    Views
    1,735

    Does anyone know what the user name and password...

    Does anyone know what the user name and password are for the MicroTech II Applied Service Tools to change parameters. Not the password for the unit. I cant remember it for the life of me and need to...
  17. Replies
    2
    Views
    237

    Tekmar 073 or 079 depending on application will...

    Tekmar 073 or 079 depending on application will work fine.
  18. Replies
    17
    Views
    1,264

    Quality control sucks these days and the people...

    Quality control sucks these days and the people building them have no pride. Not something I would expect to see in a Trane. Guess they are all headed down hill. Well at least the leak will be easy...
  19. Replies
    4
    Views
    232

    Connect to the platform, go to license manager...

    Connect to the platform, go to license manager and see what version the JACE is licensed for. If it isn't licensed for 3.5 or later there is no work around.
  20. Replies
    3
    Views
    300

    Really depends on what kind of staging. For...

    Really depends on what kind of staging. For example do you have 1 compressor with 2 unloaders, 2 compressors with 1 compressor with an unloader and 1 with out or 3 compressors, single circuit or...
  21. Replies
    17
    Views
    3,564

    Especially since there is another 4 feet to the...

    Especially since there is another 4 feet to the right that could have been used to remove the crazy offset , lower it and allow for better access to the controls and compressors.
  22. Replies
    17
    Views
    3,564

    This is a curb manufactured by a supposed AAON ...

    This is a curb manufactured by a supposed AAON approved vendor from what I was told when I questioned it. Compressors and control access is on the slope side.
    ...
  23. Replies
    17
    Views
    3,564

    Cant link pic.

    Cant link pic.
  24. Replies
    5
    Views
    290

    If there is an external I highly doubt it has an...

    If there is an external I highly doubt it has an internal. The nameplate should state if it is internally protected.
  25. Replies
    3
    Views
    289

    Going to need to open the Spyder application and...

    Going to need to open the Spyder application and change the input type from resistance to voltage input and then download to the controller.