09-16-2012, 01:10 AM
- Replies
- 19
- Views
- 2,076
Or you might want to bolt a dehum unit at the...
Or you might want to bolt a dehum unit at the return terminal for humidity control if it is necessary.
-
09-16-2012, 12:48 AM
- Replies
- 19
- Views
- 2,076
I must also clear my statement that cooling coil...
I must also clear my statement that cooling coil will of course remove moisture . Just not controllable. As long as you don't need to fix yr RH level within a certain range. You don't need reheat.
-
09-16-2012, 12:35 AM
- Replies
- 19
- Views
- 2,076
Absolutely right. I think I need to make it...
Absolutely right. I think I need to make it clear. I'm against oversizing equipment and add reheat. I also think its not much of problem in winter as long as insulation is properly done. I'm just...
-
09-16-2012, 12:34 AM
- Replies
- 19
- Views
- 2,076
Absolutely right. I think I need to make it...
Absolutely right. I think I need to make it clear. I'm against oversizing equipment and add reheat. I also think its not much of problem in winter as long as insulation is properly done. I'm just...
-
09-15-2012, 09:02 PM
Thread: Laws of Thermodynamics?
by JNXMN- Replies
- 29
- Views
- 2,097
another point of view maybe? the first law...
another point of view maybe? the first law defines the physic in OUR dimension and at the time concept we understand currently. maybe when the study of physic advance we'll discover more and see...
-
09-15-2012, 08:04 PM
- Replies
- 19
- Views
- 2,076
Hi I agree. What I meant is a deeper coil give...
Hi I agree. What I meant is a deeper coil give you better contact hence better for dehum. When you have a look the coil in an operating theater AHU you'll normally find it comes with 6 rows coil. Of...
-
09-15-2012, 08:03 PM
- Replies
- 19
- Views
- 2,076
Hi I agree. What I meant is a deeper coil give...
Hi I agree. What I meant is a deeper coil give you better contact hence better for dehum. When you have a look the coil in an operating theater AHU you'll normally find it comes with 6 rows coil. Of...
-
09-15-2012, 09:42 AM
- Replies
- 19
- Views
- 2,076
i don't think it's necessary to do this in winter...
i don't think it's necessary to do this in winter in fact.
-
09-15-2012, 08:29 AM
- Replies
- 19
- Views
- 2,076
care to elaborate?
care to elaborate?
-
09-14-2012, 11:37 PM
- Replies
- 8
- Views
- 729
do you have any ventilation for your basement?...
do you have any ventilation for your basement? normally a dehumidifier shouldn't be "smelly". did you check/clean the unit?
-
09-14-2012, 11:12 PM
Thread: Laws of Thermodynamics?
by JNXMN- Replies
- 29
- Views
- 2,097
it's actually referring to energy, heat is just...
it's actually referring to energy, heat is just one form of energy.
-
09-14-2012, 11:07 PM
Thread: Leaving system in pieces
by JNXMN- Replies
- 21
- Views
- 1,842
unfortunately this always happens. i worked for a...
unfortunately this always happens. i worked for a consulting firm. you can't imagine how many time walk on site and found out the installation does not even comply to code despite it's all specified....
-
09-14-2012, 10:59 PM
Thread: Mini-Split Misery
by JNXMN- Replies
- 13
- Views
- 1,691
is there any reason for you to remove the...
is there any reason for you to remove the reversing valve from the unit? the unit should always run in cooling in this equipment room, providing the monitoring equipment is working correctly.
-
09-14-2012, 10:54 PM
Thread: Ducted or open Returns?
by JNXMN- Replies
- 21
- Views
- 1,772
having the FCU in attic space shouldn't be a...
having the FCU in attic space shouldn't be a problem providing you have the attic space properly insulated and ventilated. of course the ductwork will still need to be sealed properly with sisalation.
-
09-14-2012, 10:35 PM
Thread: Trane Summit DX VAV setup Question
by JNXMN- Replies
- 8
- Views
- 980
You'l need to a relatively constant flow across...
You'l need to a relatively constant flow across coil for a DX system. You'll need to have a by-pass with motorised damper and pressure sensor from S/A to R/A so when the VAV close up the damper the...
-
09-14-2012, 09:48 PM
- Replies
- 19
- Views
- 2,076
There are couple issue you might need to consider...
There are couple issue you might need to consider if you planning to utilise the AC to dehumidify your house as well. you'll need to oversize your AC in order to draw out the moisture from the supply...
-
09-14-2012, 09:33 PM
- Replies
- 7
- Views
- 1,498
reducing the fan speed will also reduce the...
reducing the fan speed will also reduce the static and it could affect your air quantity which in turn reducing your cooling capacity.
-
09-14-2012, 09:10 PM
- Replies
- 3
- Views
- 965
as already mentioned by others, the HRV unit is...
as already mentioned by others, the HRV unit is not designed to take out the humidity in basement. plus you also need to somehow get the makeup air from your house above for heat recovery but unlike...
-
09-14-2012, 08:23 PM
Thread: Air Staleness Problem
by JNXMN- Replies
- 4
- Views
- 890
did you think about to install a small fan for...
did you think about to install a small fan for ventilation. you can also install a temp. sensor in your office and interface to the fan to start runing when space temperature exceeds setpoint. you'll...
-
09-14-2012, 08:17 PM
Thread: AC Compressors
by JNXMN- Replies
- 10
- Views
- 1,487
Is your condenser vertical discharge type? if so...
Is your condenser vertical discharge type? if so you might want to put a diverting cowl on top of it to change the discharge direction?
-
09-14-2012, 08:13 PM
Thread: AC Compressors
by JNXMN- Replies
- 10
- Views
- 1,487
so the hot air will offset the cooling and will...
so the hot air will offset the cooling and will heat up your place gradually. Funny thing is i did once see someone stick a small condenser in their living room blowing out through a window. i wonder...
-
09-14-2012, 08:04 PM
Thread: High suction pressure low to normal head?
by JNXMN- Replies
- 34
- Views
- 2,769
what is the flow rate, supply & return...
what is the flow rate, supply & return temperature?
-
09-14-2012, 07:55 PM
Thread: Smoke Detector.
by JNXMN- Replies
- 14
- Views
- 1,214
this will be a code requirement. maybe also for...
this will be a code requirement. maybe also for the safety measure for fire nearby or wind effect on the smoke exhaust.
-
09-14-2012, 07:54 PM
Thread: Smoke Detector.
by JNXMN- Replies
- 14
- Views
- 1,214
This is an 100% outside air unit. no return air.
This is an 100% outside air unit. no return air.