  1. Thanks Tborn. Been there. I'm going to return and...

    Thanks Tborn. Been there. I'm going to return and clean out the Steam Exhaust box. I didn't realize the top can come off. After looking at the parts breakdown it looks like it may be champers in it...
  2. Henny Penny Pressure Fryer Model #PFG-691_____ pressure won't relief after cook time

    I have a Henny Penny Pressure fryer that have been causing me problems at the end of its cook time. The employees are pulling the pressure relief valve to relieve the pressure when the product is...
  3. Replies
    6
    Views
    2,742

    That was a very good job of answering the...

    That was a very good job of answering the question being asked straight forward. That was a lot of helpful info in your reply.
  4. Has anyone been hired through RRSI (Refrigeration Recruitment Service, Inc.)?

    I was wondering if anyone out there has been recruited by RRSI (Refrigeration Recruitment Service). It seems like a good recruitment company but I just wanted some info from someone who has been...
  5. Replies
    7
    Views
    1,426

    I great company to work for. They pay double time...

    I great company to work for. They pay double time for overtime work. They treat their employees well. But you do need some experience to start because you will work on every equipment in a restaurant...
  6. To All: Thank you for your input. I...

    To All:

    Thank you for your input. I changed the txv on the unit using a low temp power head on the new existing meduim temp txv replacement I had ready and it works like a champ.
    I...
  7. Thats my problem. I can't get a part #351-6225...

    Thats my problem. I can't get a part #351-6225 txv on a local purchase; recommended by delfield tech support. But their service manual for that model calls for a part #351-6273. These delfield part...
  8. Thank you you've answered my question. It's 404a...

    Thank you you've answered my question. It's 404a refrigerant and 220#/55#. It has no fans; just a cold rail on top. Its a salad prep table used to chill mayo, lettuce, tomato, veggies, etc. And...
  9. What sizeTXV for Delfield Salad Prep Table(top rail).

    I have a Delfield (model #18699PTB, serial #BJT538601-T) R/I Cooler- Salad Prep table. Bottom cools just fine but the top does not refrigerate at all. LLS Coil energizes but still no refrigeration...
  10. Thanks mmsalgado. I applied for the position....

    Thanks mmsalgado. I applied for the position. Waiting on a response
  11. LOOKING FOR WORK IN THE LAS VEGAS AREA, TRUCK, TOOLS, NATE & OSHA 30 HR CERTIFICATION

    I am an experienced HVAC & Refrigeration Specialist in the las vegas area with my own Service Truck and Tools looking to subcontract, work full-time or part-time, or do overflow calls.********** The...
  12. Tayloer Magarita Machine(Model 340-12) technical support

    I have a taylor magarita machine that product is not thick enough. I have started to adjust the thickness slowly. But I am concern that I may be low on charge(404A) 165#/25# @ 72 degree ambient. Can...
  13. Replies
    17
    Views
    1,545

    When your fan ran continuosly your furnance more...

    When your fan ran continuosly your furnance more than likely locked out telling you something was wrong. When you reset the power you cleared the lock out. Leave the furnance alone. Let it run until...
  14. Thread: blowing fuse

    by moe663
    Replies
    17
    Views
    1,663

    When you say primary side of transformer I assume...

    When you say primary side of transformer I assume you mean the high voltage side(240v 0r 480v). Most of the time when this happens to me on the high side I find the problem where there is a break in...
  15. Replies
    18
    Views
    6,152

    Keep at it take your time with the manual. You...

    Keep at it take your time with the manual. You will find the problem. Ask your boss to send you to an ice machine manufacturing school. I think that will help you understand the sequence of...
  16. Thread: What is this?

    by moe663
    Replies
    16
    Views
    1,068

    I'm sure those cores are more expensive than a...

    I'm sure those cores are more expensive than a sweat drier but it sure beats hauling your torches on the roof.:D
  17. Replies
    13
    Views
    1,112

    There are too many variables. You need tools to...

    There are too many variables. You need tools to see whats going on. Thats just not enough info. Pressures & temperatures is the core of diagnostics. Without it no one can help you.
  18. Replies
    21
    Views
    1,340

    While some of us are struggling & on our way to...

    While some of us are struggling & on our way to the poor house-- some of us are as busy as ever. Those who are busy obviously are doing the right thing, but those of us who are not busy must face the...
  19. Replies
    150
    Views
    76,815

    Your condenser fan motor has nothing to do with...

    Your condenser fan motor has nothing to do with your mold or smell in your evap coil area. Replace the evap coil, air plenum, & maybe even a few ducts at the plenum and start a new anti mold program...
  20. Replies
    9
    Views
    772

    I've been there. You have to move the entire unit...

    I've been there. You have to move the entire unit or pull the coil. That's the your best option. I know you want to make the customer happy but its not a hard fix. I think you know the anwer to your...
  21. Replies
    45
    Views
    1,920

    Do what you like it's your home. But most HVAC...

    Do what you like it's your home. But most HVAC pros won't advise you to do such a thing. Your straight cool evap coil & metering device won't match a heatpump condenser. As soon as you install that...
  22. Thread: I need to vent!

    by moe663
    Replies
    40
    Views
    2,286

    Its funny how you're the one breaking your back...

    Its funny how you're the one breaking your back using your expertise driving across town and not being apprecieated. If that guy knew it all he wouldn't need you to come out. He would ask his boss...
  23. Replies
    37
    Views
    7,188

    With the price of freon sniffers may as well...

    With the price of freon sniffers may as well resort to real hard core drugs but let them snif. Its job security. :D
  24. Replies
    6
    Views
    577

    My Mom have one of those exhuast unit with a heat...

    My Mom have one of those exhuast unit with a heat bulb. When I visit over the holidays I run the unit 5 minutes before I shower. By the time I get out of the shower I'm smoking.:eek:
  25. Replies
    29
    Views
    1,672

    You are absolutely right: superheat, subcooling,...

    You are absolutely right: superheat, subcooling, TD, airflow, heatloss, wetbulb, removing heat from a space or product, btus, proper piping practice, electrical schematics, blue prints, etc... its...