  1. Do you ever heck online before buying a car?...

    Do you ever heck online before buying a car? Doesn't matter.

    You decreased your heat gain on the second floor by insulating your attic. So a new 5 ton would have probably be able to not only cool...
  2. Replies
    23
    Views
    520

    Didn't say it was one of your post.

    Didn't say it was one of your post.
  3. Only time will tell you if the holes not being...

    Only time will tell you if the holes not being sealed was the problem.
  4. R407C doesn't mix well with Mineral oil. So oil...

    R407C doesn't mix well with Mineral oil. So oil return to the compressor is poor, an can cause it to seize. So with out having pulled the compressor and dumping the oil. And then putting in POE oil,...
  5. Replies
    4
    Views
    158

    Sorry, this is not a DIY site. Thread closed.

    Sorry, this is not a DIY site.

    Thread closed.
  6. Replies
    71
    Views
    1,053

    TXV. Bring SC up to the data label reading.

    TXV. Bring SC up to the data label reading.
  7. Replies
    71
    Views
    1,053

    Technically, it would be added. To get the .43"....

    Technically, it would be added. To get the .43". But since you don't know how many CFM the blower is actually moving. It would be a bogus guess. The static must be measured between the air filter and...
  8. Replies
    71
    Views
    1,053

    Then it was taken wrong. So the return static is...

    Then it was taken wrong. So the return static is not a true reading. it should have been taken between the filter and the air handler. The air filter is external to the air handler. So it is a...
  9. Replies
    71
    Views
    1,053

    Was the return static taken between the air...

    Was the return static taken between the air handler and the air filter. Or was the static probe placed between the air filter and the return grilles.
  10. No, use WD-40, its a water dispersant. Non stick...

    No, use WD-40, its a water dispersant. Non stick baking sprays are oil, which will tend to make a coil have condensate going everywhere in a manor worse then you already have.
  11. Replies
    23
    Views
    520

    No legal talk or pricing talk allowed.

    No legal talk or pricing talk allowed.
  12. Unless you see on the invoice that they changed...

    Unless you see on the invoice that they changed oil. Doubt they did.

    They should have just installed an R410A system.
  13. Probably because part of the ruling/agreement is...

    Probably because part of the ruling/agreement is that ES remove advertising of it as an R22 replacement.
  14. Replies
    3
    Views
    195

    Yes it is. But the stat attempts to calc how long...

    Yes it is. But the stat attempts to calc how long it will take to cool down to the new temp. Based on run times of the previous cycles. Its not an exact science.
  15. If they actually paid for all of that to be done....

    If they actually paid for all of that to be done.

    Some customers don't pay for that kind of service. So they shouldn't expect to get it.

    You shouldn't compare what you/your company does, to...
  16. Replies
    2
    Views
    132

    Outside sensors are suppose to ne protected from...

    Outside sensors are suppose to ne protected from direct sun light, or its influence.
  17. Replies
    23
    Views
    520

    You had them inject sealant, renew and a dryer....

    You had them inject sealant, renew and a dryer. Plus refrigerant was added. Lot of good the sealant did. Why was the sealant put in. Was the system not cooling as well as it use to, that you had them...
  18. Sounds like a higher end stat was removed and a...

    Sounds like a higher end stat was removed and a lower end one installed, that can't low the blower to help remove more moisture.
  19. Now that you mention it, Yes it does.

    Now that you mention it, Yes it does.
  20. Only a tech on site could determine if its the...

    Only a tech on site could determine if its the evap coil again.
  21. Either R22 or R407C both work fine in the same...

    Either R22 or R407C both work fine in the same evap coil. However, R407C has a capacity reduction over R22. So with r407C, you don't get the same amount of cooling, as you would if they had charged...
  22. Replies
    71
    Views
    1,053

    I'd go with putting on the TXV. It gives a more...

    I'd go with putting on the TXV. It gives a more consistent evap temp. Plus reduces the risk of liquid flood back to the compressor with a slowed blower.
  23. Replies
    12
    Views
    393

    Poll: That thermostat is operating the system as it is...

    That thermostat is operating the system as it is suppose to. It brings on the cooling if the temp is .5F lower then set point, and shuts the A/C off when the temp is .5F above set point temp.
  24. Honeywell thermostat Don't have a swing range....

    Honeywell thermostat Don't have a swing range. they use CPH, not swing range adjustment, and it doesn't work anything like an adjustable sing.
  25. Replies
    6
    Views
    246

    Not no more. :grin2:

    Not no more. :grin2:
  26. Got them for you.

    Got them for you.
  27. If teh condenser fan was spinning slow. Then the...

    If teh condenser fan was spinning slow. Then the first techs evaluation of the charge being okay may be flawed.
  28. Replies
    11
    Views
    448

    Doubt your home needs 100,000 BTU 90%plus...

    Doubt your home needs 100,000 BTU 90%plus furnace. Even in your area.
  29. With extended run times your home's RH was in the...

    With extended run times your home's RH was in the 60s? Then with a 4 ton it will be even higher. Which will be unhealthy for you and your family.

    I believe we are trying to help you avoid a white...
  30. If the access panel is not sealing tight. It...

    If the access panel is not sealing tight. It could also be drawing higher humidity air in after teh coil, this would condensate on the inside of the panel.
  31. Replies
    8
    Views
    540

    If its 80f outside, and your head is at 220PSIG....

    If its 80f outside, and your head is at 220PSIG. And you have 10 of subcool, you have have a high restriction. 220 PSIG R410A is a sat temp of 76F. So your liquid line temp would be 66. But you...
  32. Thread: Big mistake

    by beenthere
    Replies
    1
    Views
    222

    As long as you vacuumed it properly, no problem.

    As long as you vacuumed it properly, no problem.
  33. So was the duct work built for 3 tons, or 4 tons....

    So was the duct work built for 3 tons, or 4 tons. Probably need a larger wire ran for the 4 ton condenser, along with a larger breaker. If the 3 ton cooled okay when it worked right, you may have...
  34. Replies
    12
    Views
    393

    Poll: Don't believe you ever posted the model number of...

    Don't believe you ever posted the model number of the thermostat in your other thread about this problem.
  35. Only the thread starter, and Pro * members can...

    Only the thread starter, and Pro * members can reply in threads in the AOP forums.
  36. The more expensive air filters often cause less...

    The more expensive air filters often cause less air flow, as they are too restrictive, and the water is drawn off the coil due to the increased return static.

    Is there any condensation on the...
  37. Are you parking the car in the garage. Or leaving...

    Are you parking the car in the garage. Or leaving the engine warm up in the garage. Does the duct system have a fresh air intake near the neighbors home.
  38. I'd want the TXV.

    I'd want the TXV.
  39. Replies
    8
    Views
    364

    During a low load evening. If the A/C runs for 5...

    During a low load evening. If the A/C runs for 5 minutes and is off for an hour. That is less then 1 cycle per hour, and it is not short cycling. Now if it was on for 5 minutes, off for 5 minutes, on...
  40. 3 ton R410A on a 3/4" suction line has a velocity...

    3 ton R410A on a 3/4" suction line has a velocity of roughly 1450 FPM. Your line set run won't be a problem.
  41. Replies
    8
    Views
    364

    Doubt it will short cycle. Just under 20 BTUs per...

    Doubt it will short cycle. Just under 20 BTUs per sq ft for heating, and 1500 sq ft per ton for cooling.
  42. Replies
    4
    Views
    214

    Moved to AOP Residential forum.

    Moved to AOP Residential forum.
  43. Replies
    1
    Views
    112

    A. Made this its own thread. B. Please don't hi...

    A. Made this its own thread.
    B. Please don't hi jack other peoples threads.
    C. This is not a DIY site.
    D. Thread closed.
  44. If the SH and SC are within spec. Then the TXV if...

    If the SH and SC are within spec. Then the TXV if it has one, isn't over feeding.
  45. Gentlemen, take it off site.

    Gentlemen, take it off site.
  46. Without those readings, its hard to give you a...

    Without those readings, its hard to give you a good idea of what the problem may be.
  47. Replies
    6
    Views
    442

    Go and read the below link. ...

    Go and read the below link.

    http://hvac-talk.com/vbb/showthread.php?1241-Welcome-to-HVAC-Talk!-Please-read-these-rules&p=9093#post9093
  48. Poll: Prices removed.

    Prices removed.
  49. Replies
    13
    Views
    423

    If its cooling okay, and you haven't had to have...

    If its cooling okay, and you haven't had to have any refrigerant added to the A/C. Don't have the A/c pressure tested. And next year, call a different company.
  50. Replies
    8
    Views
    289

    Get a heat pump with 15 KW of aux heat. Save a...

    Get a heat pump with 15 KW of aux heat. Save a lot of money on the heating bill.