    United sells Super Blue good to -30 degrees

    United sells Super Blue good to -30 degrees
  2. recover charge and weigh the amount that you...

    recover charge and weigh the amount that you recovered. and start from there
  3. Replies
    19
    Views
    1,116

    mp39

    mp39
  4. Replies
    31
    Views
    2,738

    Just use 408 and be done with it

    Just use 408 and be done with it
  5. clear the ice around the drain with a torch then...

    clear the ice around the drain with a torch then hookup a good garden hose and use hot water make sure drain is clear
    and unit is off. and deice you can feel the water temp coming from the coil if...
  6. evap coil looks like it needs a good cleaning...

    evap coil looks like it needs a good cleaning also this will help air flow
  7. the ones i serviced did

    the ones i serviced did
  8. correct me if im wrong isn't 407C used in A/C...

    correct me if im wrong isn't 407C used in A/C systems and 407A used in Refrigeration systems . for r22 replacements ?
  9. use brown rice its better

    use brown rice its better
  10. Replies
    11
    Views
    1,156

    ditto easy fiix have to replace the entire glass

    ditto easy fiix have to replace the entire glass
  11. Replies
    17
    Views
    1,817

    on your 5 th post you said they checked out fine ?

    on your 5 th post you said they checked out fine ?
  12. Replies
    4
    Views
    477

    dual voltage unit ? 208 /230 volt unit .3 wire...

    dual voltage unit ? 208 /230 volt unit .3 wire with a neutral leg ?
  13. Replies
    8
    Views
    951

    :deadhorse:

    :deadhorse:
  14. Replies
    7
    Views
    1,026

    :cheers:

    :cheers:
  15. interested in moving to north or south Carolina

    i do refrigeration work. not sure what part i want to move to any suggestions. and any good companies out there ? i have been in the field for 17 plus years.
  16. Replies
    13
    Views
    9,213

    check the voltage at the water inlet valve :gah:

    check the voltage at the water inlet valve :gah:
  17. Replies
    13
    Views
    9,213

    i have seen the voltage drop out. and the water...

    i have seen the voltage drop out. and the water valve keep running water for a few seconds and over filling the sump area. and you pull the hose and see no water .your first thought would be the...
  18. Replies
    16
    Views
    2,166

    11 1/4 inches lol

    11 1/4 inches lol
  19. Replies
    14
    Views
    1,977

    the a/c vent is a no no above an open air case

    the a/c vent is a no no above an open air case
  20. when did you ever see a chest freezer with...

    when did you ever see a chest freezer with defrost just saying ?
  21. and i don't blow off crap .

    and i don't blow off crap .
  22. Replies
    17
    Views
    1,969

    chipping the ice off will help the plate :whistle:

    chipping the ice off will help the plate :whistle:
  23. Replies
    12
    Views
    1,537

    use the tips of needle nose pliers .i believe...

    use the tips of needle nose pliers .i believe some service wrenches had them on them ?
  24. Replies
    11
    Views
    1,285

    who is paying for the repair you or the customer...

    who is paying for the repair you or the customer ? now add the prices of the oil changes ? how much more is it ?
  25. Replies
    11
    Views
    1,285

    just use 408 and be done with it no oil change...

    just use 408 and be done with it
    no oil change needed
  26. Replies
    28
    Views
    3,251

    united refrigeration sells .036 cap tube. # tc36...

    united refrigeration sells .036 cap tube. # tc36 . i would have went with the bc2 .040 . .031 seems too small
  27. Replies
    4
    Views
    853

    It will take more than a few days to thaw. i have...

    It will take more than a few days to thaw. i have seen box's down a week and there still was ice when i took apart a box to relocate it . might want to put a few heaters in it to help thaw
  28. Replies
    5
    Views
    696

    low charge

    low charge
  29. Replies
    7
    Views
    768

    use mp 66

    use mp 66
  30. Replies
    87
    Views
    7,869

    sensing tube tool

    the guy that i work with has and old one that ranco used to sell or give away .i have been looking for one my self i use a small hose clamp and attach the end to a Phillips screw driver then wrap...
  31. Replies
    4
    Views
    818

    what ever i use out of my truck stock .i keep the...

    what ever i use out of my truck stock .i keep the box top then when i go to the supply house . i restock what ever i used .
  32. Replies
    23
    Views
    2,786

    what kind of freezer M# S# ? i have seen the door...

    what kind of freezer M# S# ? i have seen the door pins get wet when unit in defrost . i believe it was a continentail . the drain line was pitched back making water drip on to box .not in pan
  33. Replies
    10
    Views
    1,844

    that's what i was taught also

    that's what i was taught also
  34. Thread: How come?

    by bacciagalupe
    Replies
    27
    Views
    5,385

    they didn't pay the bill

    they didn't pay the bill
  35. Replies
    30
    Views
    4,130

    just do what most hacks do . leave it hooked up...

    just do what most hacks do . leave it hooked up to the unit and install another and use an acess tee on the service port . and be done with it or pinch off the line cut it free and braze the new one...
  36. Replies
    5
    Views
    1,205

    the hammer kisses are the dopes knocking the ice...

    the hammer kisses are the dopes knocking the ice off the strips i would order new strips , heater , and be done with it they are sometimes hard to reinstall when they are banged up
  37. Replies
    16
    Views
    1,949

    i use nu brite for condenser coils. but you need...

    i use nu brite for condenser coils. but you need to rinse it off well . and cal clean hd for the evap coil's
  38. looking for a refrigeration job in ct.

    looking to get a refrigeration job in ct.i have 16 years in the field now need to move on before they close the doors on me. anyone hiring in ct area ?
  39. Thread: Amp meter

    by bacciagalupe
    Replies
    57
    Views
    8,679

    I use a fluke 27 love the meter . and i still...

    I use a fluke 27 love the meter . and i still have the smaller amp probe that is no longer sold .the newer ones are all big
  40. Replies
    0
    Views
    970

    Solaronics Radiant Tube Heater

    I installed a Solaronics Radiant Tube Heater and for some reason the Ignition Detection control keeps failing . every three years is this normal for these heaters?solaronics changed the original...
  41. Replies
    73
    Views
    17,541

    go to work in a supply house . crawling around on...

    go to work in a supply house . crawling around on your knees in a cluttered attic or basement isn't that fun. and when the temps reach 100 it gets even harder . Just Saying
  42. Replies
    16
    Views
    4,301

    if its flaking get a new one sounds unsafe to me...

    if its flaking get a new one sounds unsafe to me . OSHA also wants to see the labels or they will comdem them .
  43. how can you weigh in the charge on a remoted cap...

    how can you weigh in the charge on a remoted cap tube system ? the unit needs a expansion valve and a receiver and cold controls to work properly
  44. Replies
    9
    Views
    2,097

    here we go with the hot shot . hot shot sucks ....

    here we go with the hot shot . hot shot sucks . and it has r22 in it anyway . just use r22 and be done with it. or have him get a new icemaker
  45. Replies
    20
    Views
    5,116

    :whistle:

    :whistle:
  46. Replies
    27
    Views
    3,749

    i see this al the time . all they needed was a...

    i see this al the time . all they needed was a zip tie
  47. looks like a subway i/m the also get pretty...

    looks like a subway i/m the also get pretty slimed up
  48. Thread: hoshi

    by bacciagalupe
    Replies
    24
    Views
    3,159

    Hoshizaki tech service # 1- 800-233-1940 check...

    Hoshizaki tech service # 1- 800-233-1940 check the plates ? if its making ice on top and bottom and not middle / i suspect tubing seprating from the plates seen it happen alot and they kinda run ok...
  49. Replies
    18
    Views
    2,286

    isnt the sight glass usless with out a reciever....

    isnt the sight glass usless with out a reciever. need to contact master built and get proper name plate charge for that box . and weigh it in . and make shure there is not a cpr valve on that system...
  50. Replies
    18
    Views
    2,286

    did you weigh in the charge ? does the unit have...

    did you weigh in the charge ? does the unit have a reciever on it ?