  1. Replies
    134
    Views
    27,975

    Well, I could sure use a copy of WCIS also. I...

    Well, I could sure use a copy of WCIS also. I have the older version. I am trying to get it from Daikin office but no luck yet.

    thanks.

    Terry
  2. I think a P2 driver would be great. I would...

    I think a P2 driver would be great. I would prefer it to be BACnet/IP gateway. If you do BACnet/ip then any product today can use it - including tridium AX guys. I used to love Tridium when there...
  3. Replies
    262
    Views
    13,355

    I have owned an independent controls business for...

    I have owned an independent controls business for nearly 20 years. First as a JCI ABCS contractor (until they gutted the program and pulled Metasys). I have also rep'd several other lon and bacnet...
  4. Replies
    1
    Views
    363

    Smoke det false alarms on 100% OA unit

    anyone know how to deal with a supply smoke detector in a 100% OA unit and high humidity trips. the smoke would trip during dead of winter because the unit has a steam humidifier in it - so when...
  5. Thread: Trane BACnet

    by contrlguy
    Replies
    12
    Views
    1,601

    I understand Distech has a line of bacnet...

    I understand Distech has a line of bacnet controllers coming out also.

    Tridium Niagara vs OPC is different than Bacnet vs Lon. I think OPC-UA is a viable option for BAS - it is the standard in...
  6. Replies
    9
    Views
    1,012

    i have a cimetrics router for sale cheap - never...

    i have a cimetrics router for sale cheap - never used.
  7. Replies
    5
    Views
    1,610

    I would check out www.ics-controls.com. it is...

    I would check out www.ics-controls.com. it is and estimating package that has an added module for design submittals. and it is universal - works with any manufacturer.

    terry
  8. Replies
    6
    Views
    2,218

    Trane Summit - Bacnet compliant??

    Does anyone know if Trane Summit workstation is by itself, a bacnet client. can it read/write to other none trane bacnet devices on the IP network? See attached doc page 10 for bacnet PICS.
    ...
  9. Replies
    2
    Views
    566

    New Invensys UNC-410-1 R2 or AX???

    Is Invensys using AX at all or is all there Niagara stuff still R2??

    They make it very hard to integrate because the R2 stuff can and is licensed to the installing vendor - locked down.
  10. Thread: Frustrated

    by contrlguy
    Replies
    30
    Views
    2,481

    I agree that OPC and Iconics (or Wonderware, etc)...

    I agree that OPC and Iconics (or Wonderware, etc) are viable and have pros and cons when compared to Tridium. I have use Tridium and Iconics/OPC. Recently finished a Navy data center that...
  11. Replies
    19
    Views
    10,852

    CSI3 has written a siemens driver for tridium AX....

    CSI3 has written a siemens driver for tridium AX. it connects to the MBC or MEC MMI port (serial). once in tridium jace, you server as bacnet. this gets away from having to have insight running...
  12. Replies
    3
    Views
    861

    2 ways to get siemens to tridium. csi3 ax...

    2 ways to get siemens to tridium. csi3 ax driver if you connect to mbc/mec - for small projects. if you have apogee workstation, you add bacnet server option and get it via bacnet/ip. we have...
  13. Replies
    19
    Views
    10,852

    apogee has a bacnet server/client option - list...

    apogee has a bacnet server/client option - list is $8,000 but we have bought for $3,300. we have used it to serve to tridium and it worked fine. this may be better than OPC as Bacnet supports...
  14. Replies
    8
    Views
    3,107

    we are attempting to integrate honeywell data...

    we are attempting to integrate honeywell data into Apogee via EBI bacnet server and apogee bacnet client. it is not working so far. no one at honeywell seems to know how to set-up the EBI bacnet...
  15. Replies
    13
    Views
    1,970

    how can one be in the HVAC controls business and...

    how can one be in the HVAC controls business and not know about a Tridium Jace (rebranded and use by almost half of the industry - JCI, Honeywell, Invensys, Steafa, Distech - I am sure I missed some)...
  16. Replies
    16
    Views
    1,507

    sysint, both JCI and Honeywell are scheduled...

    sysint,

    both JCI and Honeywell are scheduled to release bacnet versions for the FX line (JCI) and Spyder (Honeywell). JCI has done a poor job with their Lon comm cards for the FX controllers...
  17. Replies
    3
    Views
    1,305

    Siemens Apogee Bacnet Client setup

    we are trying to get siemens apogee with the bacnet client option installed to upload bacnet points from Honeywell EBI. we can browse and see them,but we can't make it "connect" We created a new...
  18. Replies
    16
    Views
    2,482

    mkennedy we are having a similar problem. in...

    mkennedy

    we are having a similar problem. in system profile, we an do a whois and the honeywell EBI server responds IM. and we can also browse points and read live valvues. however the bacnet...
  19. Replies
    16
    Views
    2,482

    we are attempting to integrate honeywell EBI into...

    we are attempting to integrate honeywell EBI into Siemens Insight via bacnet server (honeywell) and bacnet client (siemens) options added to their respective software. We did it once before going...
  20. Replies
    5
    Views
    841

    niether

    today, all controls systems are nearly equal in terms of their functionality. so, what you really want to focus on is product that can't lock you up. Seimens and JCI branch are the masters of the...
  21. Thread: Johnson ABCS

    by contrlguy
    Replies
    18
    Views
    2,365

    I agree the FX controller line is good and...

    I agree the FX controller line is good and coupled with Tridium, it makes a good system. But, JCI was and still is a branch oriented company. It is sad, but they play favorites. The ABCS channel...
  22. Replies
    11
    Views
    2,472

    the key to Tridium AX interoperability is the...

    the key to Tridium AX interoperability is the NiCS statement within the Jace. OEM's or rebrander's can restrict what Tridium calls station compatibility and engineering tool compatibility. The FX40...
  23. Replies
    11
    Views
    2,472

    the bottom line: They are both are JCI branded...

    the bottom line:

    They are both are JCI branded products. They are web-servers and function well. The main differentiator is that the NAE is sole-source, branch-offce only(lock-um and loot-um);...
  24. Replies
    6
    Views
    1,600

    what part# do you have. I am interested

    what part# do you have. I am interested
  25. Thread: Vendor ?

    by contrlguy
    Replies
    25
    Views
    2,378

    sysint I agree that Tridium does not use the...

    sysint

    I agree that Tridium does not use the LNS database which is what makes the Ilon, Plexus, Inet, etc work together. And I was not a fan of Tridium until: 1. the AX version was released and 2....
Results 1 to 25 of 65