    Copy the Wafer font from the Eikon folder to the...

    Copy the Wafer font from the Eikon folder to the fonts folder under you Windows directory. This is why the MB are stretched.
  2. Good topic. Google it...and you get even more...

    Good topic. Google it...and you get even more confused. Always 3 wires..always works.
    The old school modbus guys here use 3 wire in the industrial rs485 controls.
    New ALC recommends it. But the...
  3. Replies
    3
    Views
    262

    http://www.automatedlogic.com/eikon-for-educators/...

    http://www.automatedlogic.com/eikon-for-educators/%20/
  4. Replies
    42
    Views
    2,184

    Ask the salesman to bring up a site on their...

    Ask the salesman to bring up a site on their smartphone. Then grab his phone and see if you are comfortable navigating the graphics and logic without any training.
    If you he can't do that...run!
  5. Remember having so many issues with...

    Remember having so many issues with bi-directional printers that we stopped using the dongles. Kind of remember it being a simple change in a text file. Or maybe deleting it. Hope it jogs someones...
  6. I recall a software hack to make it work without...

    I recall a software hack to make it work without the dongle, but I can't recall and it was pre-XP. I haven't touched Signal since about '01. Hope someone can PM you the answer.
  7. Replies
    4
    Views
    229

    Well spoken Dracula. Keep backups of backups....

    Well spoken Dracula. Keep backups of backups. External hard drives are cheap.
    Personally I have 2 usb hard drives in my truck and 1 at home. If you lose any data it's your fault.
    Got job and...
  8. Thread: BACnet.....

    by control$
    Replies
    26
    Views
    3,102

    It would be easier if I could go directly from...

    It would be easier if I could go directly from the logic in one program to the logic in another. Without opening 4 windows.
  9. Thread: BACnet.....

    by control$
    Replies
    26
    Views
    3,102

    Having to program all that heat/cool/airflow/run...

    Having to program all that heat/cool/airflow/run requests stinks...doing that now on a non alc campus.
  10. Thread: BACnet.....

    by control$
    Replies
    26
    Views
    3,102

    Pretty rare for me to use canned anything. But...

    Pretty rare for me to use canned anything. But they have tons of programs to steal from. Why reinvent the wheel? And amazing selection of graphics for any application including most 3rd part stuff....
  11. Thread: Btu

    by control$
    Replies
    9
    Views
    335

    Typical the monthly total btu is converted in...

    Typical the monthly total btu is converted in kwh. The kwh is then converted to $$ using the time of day to base low and high rate kwh for billing.
  12. Thread: BAS Training

    by control$
    Replies
    7
    Views
    524

    2nd for the Honeywell Grey book. It is the bible.

    2nd for the Honeywell Grey book. It is the bible.
  13. Replies
    2
    Views
    189

    Will give it a try next week. Thanks.

    Will give it a try next week. Thanks.
  14. Thread: BACnet.....

    by control$
    Replies
    26
    Views
    3,102

    It's a hard move to Tridium. ALC makes it so it...

    It's a hard move to Tridium. ALC makes it so it easy. Bigger markets have a few ALC dealer (3 in LA), not so much in the smaller ones.
  15. Replies
    2
    Views
    189

    Eaton Power Xpert Meter

    Trying to reset the KWH's monthly via Modbus/Ip. I have the complete list from the help webpage, but I can't seem to find the register on the list. I know it can be done physically at the meter.
    ...
  16. Whoever installed it should be able to get the...

    Whoever installed it should be able to get the license. But why? Just upgrade it to WebCTRL 6 and be done with it.
    If you don't have backups your going to have to contact the orginal installer with...
  17. A slightly used T87f

    A slightly used T87f
  18. You still need a backup on person.

    You still need a backup on person.
  19. You win..

    You win..
  20. Exactly what system does not have database???!??!!

    Exactly what system does not have database???!??!!
  21. Replies
    7
    Views
    334

    Exec 4 from the mid 90's. They got their moneys...

    Exec 4 from the mid 90's. They got their moneys worth out of it already. Can be brought up to bacnet and tied into bacnet/ethernet at the LGE. But really not worth it.
    Make sure to give them a logic...
  22. Replies
    6
    Views
    434

    Is the ip switch set to default? If so it's now...

    Is the ip switch set to default? If so it's now DHCP with 6.0 driver.. Set the IP address in terminal mode.
  23. Replies
    18
    Views
    1,057

    To still be at work on the 24th! And needed on...

    To still be at work on the 24th! And needed on the 26,27,28th.... Can't complain about being employed I guess.
  24. UNI, WebPRTL

    UNI, WebPRTL
  25. Replies
    8
    Views
    512

    Multistack, DesChamps, Lumisys

    Multistack, DesChamps, Lumisys
  26. Dammit! I went through the trouble of screen...

    Dammit! I went through the trouble of screen capturing all this just to prove me right!! No harm done. I'm in the same boat. I've talked with with CC, but they wouldn't help even though the developed...
  27. Didn't recall saying anything about Arcnet.

    Didn't recall saying anything about Arcnet.
  28. Have a large site that I installed Contemporary...

    Have a large site that I installed Contemporary Controls bacnet IP/mstp. Originally we installed to it pull in some third party stuff, but as time went on I installed ZN's SE's and so on.
    Bottom...
  29. Replies
    20
    Views
    615

    Per your screen capture, it looks as if your...

    Per your screen capture, it looks as if your already MST/TP. See if MS/TP is enabled at the LGR.

    533781
  30. Replies
    20
    Views
    615

    Have you tried to network discover from WebCTRL?...

    Have you tried to network discover from WebCTRL? Turn off static bindings and give it a try. Are the points checked as Network Visible?
    Done a few with different vendors and front ends and don't...
  31. I second the Onicon System 10. The BTU meter...

    I second the Onicon System 10. The BTU meter comes as a complete package, flow meter, temp sensors, and meter. All setup and ready to go once installed. Very straight forward to install.
  32. Replies
    33
    Views
    2,410

    Nope. Pneumatics is intuitive and can be worked...

    Nope. Pneumatics is intuitive and can be worked on without a password and proprietary software.
  33. Replies
    20
    Views
    615

    Yes you can, but you'll be blind. If you want to...

    Yes you can, but you'll be blind. If you want to see what is going on you'll need WebCTRL. So add a MS/TP Network to the LGR and wire the Sitelink to the S1 port on the LGR (Defaults to 76800 so...
  34. Replies
    19
    Views
    963

    Can't make that stuff up. You have to live it to...

    Can't make that stuff up. You have to live it to believe it. Had a minority owned electrical contractor wire the 120/24 transformer backwards on about 12 uv's and then turn it on. The GC called me...
  35. Replies
    19
    Views
    963

    The heat breaks down the insulation. The higher...

    The heat breaks down the insulation. The higher potential shorts first.
  36. RS Plus - Bacnet Zone Control - Nope PID - New...

    RS Plus - Bacnet
    Zone Control - Nope
    PID - New yes, old no.
    Airflow - Yes.

    Why do you need all that on another system? In the end WebCTRL is going have to stay anyway as long as any ALC...
  37. Replies
    33
    Views
    2,410

    How exactly is Niagara NOT proprietary? Ain't...

    How exactly is Niagara NOT proprietary? Ain't Niagara Tridium? How's that open?
  38. Replies
    33
    Views
    2,410

    Don't see this an any big deal. Tridium is as...

    Don't see this an any big deal. Tridium is as locked down as anything else.
  39. Replies
    299
    Views
    31,005

    What is a non-routing protocol?? What the heck...

    What is a non-routing protocol??
    What the heck are you using that requires a license????
  40. I did a few hundred of those Carel...

    I did a few hundred of those Carel Controllers..PIA. DO NOT USE COV. ONLY POLL THE ANALOG POINTS.
  41. Replies
    3
    Views
    606

    Yes it is. Knock it off.

    Yes it is. Knock it off.
  42. Replies
    5
    Views
    457

    Yep. Put everything in hand then replace. I can...

    Yep. Put everything in hand then replace. I can remember Siebe tried to sell that Satchwell stuff back in the NW8000 days..Laughable back then.Good luck.
  43. Thread: PEM Program

    by control$
    Replies
    2
    Views
    285

    Originally all you had was canned applications...

    Originally all you had was canned applications for the Pem's.Most where one size fit nothing right. My first canned BC Pem application opened the oa damper and shut the hw valve on a freeze! Latter...
  44. Replies
    1
    Views
    238

    Your out of luck without the OEM permission....

    Your out of luck without the OEM permission. Without the Bacview password, I would network discover the points and modify what is available that way. You should be able to get the password from the...
  45. Replies
    299
    Views
    31,005

    The the thread that will never end! Real answer...

    The the thread that will never end!
    Real answer - Whatever is there now and your comfortable with.
    My answer - If you can't find the logic button, it ain't worth the trouble.
  46. Replies
    16
    Views
    622

    "1 PRGs initialized. 1 PRGs running." If the...

    "1 PRGs initialized. 1 PRGs running." If the program on the modstat matches your download, your ok.
  47. Replies
    16
    Views
    1,136

    I never seen a union control guy in NJ. I needed...

    I never seen a union control guy in NJ. I needed to join one to keep working in LA.
  48. Replies
    21
    Views
    1,571

    517901

    517901
  49. Guess he was an old Barber Coleman guy. Old...

    Guess he was an old Barber Coleman guy. Old System 8000 parts.
  50. Replies
    7
    Views
    427

    I have other ways of doing it, if that doesn't...

    I have other ways of doing it, if that doesn't work. Carrier is sorta limited on logic I guess.