    Stale data issues

    I have 2 sites where we are using the comm4 driver. Everything works fine at times but I get a lot of stale data issues which keep the devices from going into occupancy and such. I have tried...
  2. We do a lot of tracker and varitrac in our office...

    We do a lot of tracker and varitrac in our office and they are not difficult to set scheduling in if you follow the manual. It is just really time consuming setting them up because of the way they...
  3. Replies
    9
    Views
    1,405

    Ok thanks now it makes sense I have been using...

    Ok thanks now it makes sense I have been using the file in the lonTrane module. I will check out making my own.
  4. Replies
    9
    Views
    1,405

    That must only appear on an FX because there is...

    That must only appear on an FX because there is no personality2 or any of the points you mention on a Jace. Unless you have a different module than the lonTrane one.
  5. Replies
    9
    Views
    1,405

    I have never seen those points pull in from a ZN....

    I have never seen those points pull in from a ZN. Am I missing them somewhere?
  6. Replies
    9
    Views
    1,405

    They are inside the proprietary variables. You...

    They are inside the proprietary variables. You can create a switch and use a boolean to turn it off and on I call this thumbwheel enable/disable. Map a numeric remote setpoint and the nvoSetpoint to...
  7. Replies
    12
    Views
    2,474

    I have done several jobs removing the BCUs and...

    I have done several jobs removing the BCUs and using the infocon drivers. Everything went very well and that is the route I would go. I would not replace the few PCM but would leave then in the BCU...
  8. Replies
    30
    Views
    5,589

    Could I get a copy of those also? I had them from...

    Could I get a copy of those also? I had them from my days at JCI but lost them in a computer upgrade. My email is in my profile.

    Thanks
  9. Thread: Tracer SC

    by dave2142
    Replies
    8
    Views
    1,381

    To be honest the SC is still real buggy with a...

    To be honest the SC is still real buggy with a lot of stuff. It will take the number of devices per the license but seems to have a lot of buggy comm and web interface issues. It has gotten 200%...
  10. Replies
    20
    Views
    1,856

    Contact me at the email in my profile. Or send me...

    Contact me at the email in my profile. Or send me the backups and I will see what I can do. I will need to find the program again. Have not been doing much with it for the last year or so.
  11. Replies
    9
    Views
    1,558

    I would agree just remove the CCP and use the...

    I would agree just remove the CCP and use the comm4 driver in Jace. Replicating the CCP software would be very easy it really does not do anything special.
  12. Replies
    26
    Views
    8,009

    Do not know anything about Struxureware but its...

    Do not know anything about Struxureware but its is far from what the AX can do. I am sure in the future it will be a viable front end but for now it still has a lot of work to go. I doubt it will...
  13. Replies
    13
    Views
    1,770

    Not been with JCI in several years but was around...

    Not been with JCI in several years but was around when the FEC first started hitting the market good to see that the adaptive tuning has not gotten any better. What worked for me in the past was to...
  14. Replies
    31
    Views
    6,440

    Should work fine

    Should work fine
  15. Replies
    31
    Views
    6,440

    I would install a large Jace with comm4 driver...

    I would install a large Jace with comm4 driver and remove the BCU with the comm4 devices and go direct into the Jace. The comm4 from Infocon works very well I have used it several times and it works...
  16. Replies
    20
    Views
    4,950

    Trane will not even given those Summit...

    Trane will not even given those Summit proprietary variables out to those of us who work for corp. Trane. We have been doing a lot of Tridium instead of Summit and cannot get that data for our own...
  17. Replies
    7
    Views
    1,210

    Try a Jace with comm4 driver or lontalk driver.

    Try a Jace with comm4 driver or lontalk driver.
  18. Replies
    52
    Views
    5,038

    I am with osiyo 100% on this one. I understand...

    I am with osiyo 100% on this one. I understand cloud computing but not sure how it relates to our world. Are they suggesting that the main cotroller programming reside on a system somewhere outside...
  19. Replies
    52
    Views
    5,038

    Did several big systems back in my days at JCI...

    Did several big systems back in my days at JCI one AHU had 4 maxed out DX9100 controllers and a unt to handle it. The trick was to separate the systems into individual controllers and use direct...
  20. Replies
    2
    Views
    1,402

    Thanks already tried that have set at 1 second I...

    Thanks already tried that have set at 1 second I think the issue might be trunk noise also. Have two trunks on the device and using the dual rs/232/485 card. They had issues with Summit so could be a...
  21. Replies
    2
    Views
    1,402

    Comm4 driver in Jace

    Anyone ever used the infocon comm4 driver in a Jace. I am having some issues with one. It works but a lot of my points are going stale and not updating it get errors like this "Could not post write...
  22. Replies
    57
    Views
    6,225

    Poll: Matrix you are correct in what you say. I work...

    Matrix you are correct in what you say. I work for one of those big boys and the truth is that they all think that if they open up and customers get smart and realize they are not locked in then they...
  23. Replies
    57
    Views
    6,225

    Poll: A majority of the new controllers out on the...

    A majority of the new controllers out on the market use Linux operating system and the kernel core so opeing them up would not be an issue. As for the for the liability some have stated like...
  24. Replies
    30
    Views
    2,386

    You can do a lot of batch changes inside the xml...

    You can do a lot of batch changes inside the xml or px code. Just create one point the way you want it then find the lines of code for that point and do a search and replace in the code to replace...
  25. Replies
    8
    Views
    1,740

    The point limit only applies to RS232 which...

    The point limit only applies to RS232 which hardly anyone uses now anyways. Only limit is really how long you fingers can last to create all the points. The .pdf is very misleading as you need to...
  26. In our area at least 70k seems to be tops for...

    In our area at least 70k seems to be tops for this job. Or maybe I am getting screwed doing all the same things in the description and AX certified. Our area here in Northern Ohio this is about...
  27. Replies
    6
    Views
    647

    Figured it out was easy to do with program...

    Figured it out was easy to do with program editor once I figured out the way to make names non identical. Thanks
  28. Replies
    6
    Views
    647

    I take it you would do it in robot editor....

    I take it you would do it in robot editor. Writing java is not an issue just not done anything with robot. Could you give me an idea of where to start?
  29. Replies
    6
    Views
    647

    Add histories in AX via program service

    I assume that there is a way to add a history to a batch of points via program service. I have found mention of it on Niagara Central but no instructions as how to do it.
  30. Replies
    17
    Views
    2,040

    You will not find a nvoOADamper point. I use econ...

    You will not find a nvoOADamper point. I use econ out under nvoUnitStatus for damper position. I use a toggle switch to control local or remote setpoint. Create a binary point under the devices and...
  31. Replies
    14
    Views
    1,643

    Not played with the ranges but for the local...

    Not played with the ranges but for the local stpoint option it is fairly easy. I just create a boolean point called local/remote mode , and a numeric writable called remote setpoint.Send the boolean...
  32. Replies
    17
    Views
    2,040

    Set the FX to always zero length domain. Use nl...

    Set the FX to always zero length domain. Use nl utility to set dsn 0 to length 1 id 11 subnet 1 node as it is. Set dsn 1 to 0 length no domain id subnet 1 and same node as dsn 0. Now you can...
  33. Replies
    15
    Views
    1,514

    Found the issue is with firmware in the 580 lower...

    Found the issue is with firmware in the 580 lower than 4.0.1. If you upgrade to 4.0.1 the issue goes away. Appears to be a memory buffer issue in previous firmwares. The memory gets full and for some...
  34. Replies
    3
    Views
    1,130

    Trust me when I say you are better off without...

    Trust me when I say you are better off without it. Wait a few years until they get the bugs out. I would go with an AX, has the same abilities and more without the little quirks that the SC is having.
  35. Replies
    6
    Views
    933

    Had the same issue with same devices and found it...

    Had the same issue with same devices and found it was a bad capacitor on one of the units cards. The only way I found it was to take devices off the trunk one at a time and watch the system to see...
  36. Replies
    17
    Views
    3,382

    Would you be able to give me that information...

    Would you be able to give me that information also?
  37. Replies
    19
    Views
    2,420

    I would keep an eye on the controller. The...

    I would keep an eye on the controller. The symptoms you described and the apparent fix when you power cycle the controller are exactly what I was seeing. The power cycle would fix the issue for a...
  38. Replies
    19
    Views
    2,420

    Upgrade the 580 to the newest image, make sure...

    Upgrade the 580 to the newest image, make sure you have the new trane.jar and recommission all should be ok then. Just a heads up once a 580 is commissioned on a Jace it does not like to upgrade very...
  39. Replies
    10
    Views
    623

    The vv550 will to space CO2 control. You should...

    The vv550 will to space CO2 control. You should see a snvt for nivSpaceCO2 in ppm bind that to your MP580. The only issue is you will need to connect the input in tgp to a ppm snvt output. That...
  40. Replies
    10
    Views
    1,264

    BCU and MP are still around but the new front end...

    BCU and MP are still around but the new front end is going towards the Tracer SC which is comm5 and bacnet with web access.
  41. Replies
    10
    Views
    1,264

    Trane does have an mstp line of controllers now....

    Trane does have an mstp line of controllers now. It is very small selection meaning that the programmable and vav controller are the same device. Check into the UC400-800 line of controllers. Not...
  42. Replies
    15
    Views
    2,262

    No real advantage to the JENEsys just the device...

    No real advantage to the JENEsys just the device I am familiar with, they do have an N2 driver so you could do the N2.

    As for the ES I should clarify. It depends on what you are wanting. It is an...
  43. Replies
    15
    Views
    2,262

    I would recommend the JENEsys which is for all...

    I would recommend the JENEsys which is for all purposes an FX or AX rebranded. I would however not recommend the ES server not seen too many installs where it worked right or the customer was really...
  44. Replies
    15
    Views
    1,355

    [QUOTE=rellufnalla;7127882]The advantage to LEED...

    [QUOTE=rellufnalla;7127882]The advantage to LEED certification is reduced operating costs, about $1.50 per square foot.

    Seems like the certification has nothing to do with operating cost. The...
  45. Replies
    15
    Views
    1,355

    This may sound like a stupid question but why...

    This may sound like a stupid question but why would you want to go leed? Seems like a lot of time and money for no payback. I am wrong quite often but looks like it is more of a publicity, govt....
  46. Replies
    0
    Views
    444

    AX and old Trane controllers

    Has anyone been able to successfully bring Trane comm2 devices into an AX or even a Tracer 100i panel? Mainly old UCP chillers
  47. Replies
    39
    Views
    6,109

    Trane has partnered with Lynxspring which is just...

    Trane has partnered with Lynxspring which is just a rebranded Jace. The product is only supposed to be used as a integration bridge to replace the field server. However a good many of us are finding...
  48. Replies
    15
    Views
    1,514

    Seen it with just Rover. Had one today I took...

    Seen it with just Rover. Had one today I took offline and went direct with Rover to and did complete reset of the device in active mode so that I could upgrade the firmware. Did this as soon as I put...
  49. Replies
    15
    Views
    1,514

    I really have been seeing the problem only with...

    I really have been seeing the problem only with the new blue boards oddly enough. But I have also had issues with Rover and these same boards where I get crazy err and ? marks on points. Seems more...
  50. Replies
    15
    Views
    1,514

    That was my first issue but you are right it was...

    That was my first issue but you are right it was a lonworks.jar and trane.jar file update that fixed that issue.