04-19-2013, 12:08 AM
Thread: Zoning systems
by Ac_man- Replies
- 2
- Views
- 224
Zoning systems
So I would like to know how everyone feels about having zoning dampers on a one zone hvac unit..reason I ask Is cause I ran into a few problems with motors going fault as well as the damper motor,...
-
04-18-2013, 11:47 PM
Thread: Compressor amp draw
by Ac_man- Replies
- 9
- Views
- 556
To doc havoc, I was just asking the question...
To doc havoc, I was just asking the question about high amps the opposite of when a compressor draws low amps, just a question, sorry for the confusion
-
04-17-2013, 11:34 PM
Thread: Compressor amp draw
by Ac_man- Replies
- 9
- Views
- 556
Compressor amp draw
So it's that time of the season here in the northeastern side of the US.. Now I ran into a bad scroll compressor 2.5 ton r22 rated 19amps and drew 6.7amps common and 5.4 start, outdoor temp was 80.....
-
04-04-2013, 02:57 PM
Thread: AC checks during mild weather
by Ac_man- Replies
- 11
- Views
- 706
AC checks during mild weather
So we recently have started doing AC checks here in the northeastern side of the US. The way I perform my checks are by wrapping a plastic contractor bag around the entire condensing unit and letting...
-
03-12-2013, 08:07 PM
- Replies
- 16
- Views
- 778
This is the Ask Our Pro's forum. In order to post...
This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
-
03-12-2013, 07:30 PM
Thread: Txv's testing
by Ac_man- Replies
- 7
- Views
- 433
Txv's testing
When checking for restricted txv's during AC season, I've been taught to place it in hot water to see if it would open,which is one way of testing, any other recommended methods of testing??..thanks
-
03-01-2013, 02:33 PM
Thread: Aux heat sequence
by Ac_man- Replies
- 19
- Views
- 711
I feel the same way freonjohn, they shouldn't be...
I feel the same way freonjohn, they shouldn't be allowed on this site with smarta** answer like that
-
03-01-2013, 02:12 PM
Thread: Aux heat sequence
by Ac_man- Replies
- 19
- Views
- 711
So my understanding is that u can wire a couple...
So my understanding is that u can wire a couple of elements to regular heat and then wire all to emergency heat correct?? Which means 2 elements to "w2" and then all to "e" em heat,correct??
-
02-28-2013, 11:55 PM
Thread: Aux heat sequence
by Ac_man- Replies
- 19
- Views
- 711
Aux heat sequence
During aux heat on a heat pump, how many elements come on if we say its a 15kw pack in conjunction with the heat pump to raise the temp 1 degree??
-
02-22-2013, 11:40 PM
Thread: Dual fuel testing
by Ac_man- Replies
- 10
- Views
- 357
Thanks guys
Thanks guys
-
02-22-2013, 09:17 PM
Thread: Dual fuel testing
by Ac_man- Replies
- 10
- Views
- 357
Dual fuel testing
I don't have much experience testing dual fuel units during heating checks, how can I by pass the heat pump during mild winter to test the gas furnace??and how do I by pass furnace to test heat pump...
-
02-22-2013, 09:10 PM
Thread: Carrier Furnace..any ideas?
by Ac_man- Replies
- 31
- Views
- 1,498
It's the pressure switch I've replaced 4x already...
It's the pressure switch I've replaced 4x already this winter season in northern VA pretty much on carriers..also have a magnihilix to test it while running to see what the pressure are
-
01-11-2013, 12:33 AM
Thread: outdoor thermostat
by Ac_man- Replies
- 13
- Views
- 1,022
While we're on the topic of dual fuel units, I...
While we're on the topic of dual fuel units, I went to a 5 ton oil furnace/ 5 ton heat pump dual fuel call some time ago,complaint was the breaker would trip about once or twice during the day....
-
01-11-2013, 12:06 AM
Thread: Hard Start Capacitors
by Ac_man- Replies
- 26
- Views
- 1,503
What's the purpose of the potential relay and how...
What's the purpose of the potential relay and how does it work on the hard start kit??and is it also recommended on r410a units with txv's??
-
01-10-2013, 11:48 PM
Thread: Flame sensor is good
by Ac_man- Replies
- 57
- Views
- 2,293
Well I went back to this call earlier today and...
Well I went back to this call earlier today and double checked all my ground connections. i removed one that was connected to the frame of the transformer and placed it with the rest of the ground...
-
01-08-2013, 10:15 PM
Thread: R410a leak dectector
by Ac_man- Replies
- 11
- Views
- 458
Im going to double check the manual again to see...
Im going to double check the manual again to see what refrigerants it detects again
-
01-08-2013, 10:13 PM
Thread: Flame sensor is good
by Ac_man- Replies
- 57
- Views
- 2,293
Thanks for the info
Thanks for the info
-
01-08-2013, 10:06 PM
Thread: Flame sensor is good
by Ac_man- Replies
- 57
- Views
- 2,293
What did you do as a repair
What did you do as a repair
-
01-08-2013, 09:59 PM
Thread: Flame sensor is good
by Ac_man- Replies
- 57
- Views
- 2,293
Would i have to disconnect any neutral wires or...
Would i have to disconnect any neutral wires or just test to a OPEn neutral terminal?
-
01-08-2013, 09:52 PM
Thread: R410a leak dectector
by Ac_man- Replies
- 11
- Views
- 458
I have the same one, it goes off when u expose it...
I have the same one, it goes off when u expose it to a jog Of 410, But when i actually look for a 410 during a service call it rarely goes off even After i replaced the tip, how old is yours,ive had...
-
01-08-2013, 09:47 PM
Thread: Flame sensor is good
by Ac_man- Replies
- 57
- Views
- 2,293
Thanks bro
Thanks bro
-
01-08-2013, 09:28 PM
Thread: Flame sensor is good
by Ac_man- Replies
- 57
- Views
- 2,293
I did check for gas pressure and was 3.5"wc. Next...
I did check for gas pressure and was 3.5"wc. Next i removed all burners and cleaned them out. After all this, still had same symptoms. What should i do next guys
-
01-08-2013, 09:21 PM
Thread: Flame sensor is good
by Ac_man- Replies
- 57
- Views
- 2,293
I did check the pressure for any debris and was...
I did check the pressure for any debris and was clean, i did put My probes on the sensor and the wire that connects to the board to get a 2.2ua.. I did call one Of My senior tech and he told me to...
-
01-08-2013, 09:16 PM
Thread: R410a leak dectector
by Ac_man- Replies
- 11
- Views
- 458
R410a leak dectector
What electronic leak detector would you guys recommend for r410a
-
01-08-2013, 09:12 PM
Thread: Flame sensor is good
by Ac_man- Replies
- 57
- Views
- 2,293
2.2
2.2
Results 1 to 25 of 32