    Navien Boilers

    Gentlemen, .... What's our feelings on these new wall hung Navien 210/240 boilers, .... Gas fired.... heat and domestic hot water???...... On the secondary loop, how effective is a 600 sq. ft....
  2. Replies
    46
    Views
    6,175

    Why wouldn't that riser freeze in the winter,...

    Why wouldn't that riser freeze in the winter, there is always water in it. How does the additional vent take care of expanding hot water...... Many Thanks.... Frank S
  3. Replies
    46
    Views
    6,175

    Why would I have STEAM vent in the attic.... I...

    Why would I have STEAM vent in the attic.... I have seen H.W. expansion tanks in attics, and they did have a vent piped along with and above the exp. tank.... The second floor of these cottages have...
  4. Replies
    46
    Views
    6,175

    No, I had not thought about vented risers in the...

    No, I had not thought about vented risers in the attics. If the cottages are both two story, and the seven garages single story, what would be the reason for vent risers in the attic...... Thanks...
  5. Replies
    46
    Views
    6,175

    Will look into the problem when we get back to...

    Will look into the problem when we get back to the cottage on 12-26..... Thanks again..... Much appreciated.... Frank S.
  6. Replies
    46
    Views
    6,175

    Thanks for the info..... I'm trying to find the...

    Thanks for the info..... I'm trying to find the problem.... And I wont sleep till its rectified!!!! Thanks again... Frank S
  7. Replies
    46
    Views
    6,175

    You guys are the best... Thanks for your help and...

    You guys are the best... Thanks for your help and looking out for me!!!!!!!
  8. Replies
    46
    Views
    6,175

    Piping was first installed in the early 1900's. ...

    Piping was first installed in the early 1900's. This set of cottages and garages and mansion is part of the "Goodyears" estate that has changed hands since then. I really cant tell you why there...
  9. Replies
    46
    Views
    6,175

    Hunting for leaks on Wednesday.... Thanks for...

    Hunting for leaks on Wednesday.... Thanks for your time...Frank S.
  10. Replies
    46
    Views
    6,175

    I think the boiler would certainly flood due to...

    I think the boiler would certainly flood due to old return lines and I would see the flooding in the sight glass, however, the sight glass never rises past 1'' above the lower glass gauge...
  11. Replies
    46
    Views
    6,175

    The condensate vent line is a 180 degree piece of...

    The condensate vent line is a 180 degree piece of 1' black pipe. The basement is 10' high, so I will say that the vent line is 9' high from the pump to the ceiling, has a double elbow, and then the...
  12. Replies
    46
    Views
    6,175

    Water is constantly being added automatically.......

    Water is constantly being added automatically.... The water level never exceeds 1'' above the bottom of of the glass sight glass.
  13. Replies
    46
    Views
    6,175

    Steam Boiler---- Excessive water usage

    TO: Tinknocker to another New York TinKnocker...

    PLEASE...I need a response from your last statement ..... If the glass gauge is always showing a acceptable water lever of approximately 1'' above...
  14. Replies
    46
    Views
    6,175

    Perhaps...Every vent may be slightly leaking.......

    Perhaps...Every vent may be slightly leaking.... after the holiday we were planning to look into the steam vents on a individual basis
  15. Replies
    46
    Views
    6,175

    Both zones are Cast iron radiation.... Leak...

    Both zones are Cast iron radiation.... Leak tested boiler only..... excessive water consumption was never noted to us prior to installing the new boiler... are you from pulaski rd in ny.... Bethpage...
  16. Replies
    46
    Views
    6,175

    No domestic h.w. loops....No side arms........

    No domestic h.w. loops....No side arms..... Separate 75 gallon, oil fired h.w. heater

    ALSO NO visible water leaking..... 24 hours after my last post.... Just spoke to the tenant in the left...
  17. Replies
    46
    Views
    6,175

    Cut in is 1 with a differential of 1..... cut out...

    Cut in is 1 with a differential of 1..... cut out is set at 3 with a differential of 1.....

    ALSO NO visible water leaking..... 24 hours after my last post.... Just spoke to the tenant in the left...
  18. Replies
    46
    Views
    6,175

    Excessive water-steam boiler

    Did you check in the cottages and the garages for a leak.

    NO visible water leaking..... 24 hours after my last post.... Just spoke to the tenant in the left cottage... due to the holiday weekend...
  19. Replies
    46
    Views
    6,175

    Steam Boiler, Excessive water useage

    Removed a older Weil McLain 578 steam boiler and installed a brand new (within the past two weeks) Weil McLain 580 steam boiler... Ran HERCULES Scout in the boiler for 2 weeks and now its been...